34 kòd pou BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel, Water Pro BP7 Series (Balboa BP7 system board) - BP7 with Fixed Heater, Remote Heater, Low Flow Heater, BP2000 Series spa control system (Balboa BP2000, Hydro-Quip BP Series kit), Water Pro BP7 with Low Flow Heater (Balboa BP7 system board): sa chak kòd vle di, sa pou w tcheke an premye ak ki lè pou w rele yon teknisyen.

Sekirite an premye

Panèl kontwòl: bò gwo vòltaj yon sistèm otomatik oswa yon kontwòl spa se travay pou yon teknisyen ki kalifye oswa yon elektrisyen. Koupe kouran an nan breaker a anvan w louvri yon pòt ki kite fil yo parèt. Pa janm kontoune high limit yon spa ni yon GFCI.

Ale nan yon kòd

KòdSa li vle di
M019Priming Mode: li antre chak fwa yo mete kouran pandan 4 minit pou itilizatè a ka mache chak ponp epi verifye…
TOO COLDToo Cold - Freeze Protection (twò frèt - pwoteksyon kont frizè): sistèm nan santi yon frizè posib, oswa Aux…
M029Water is too Hot (OHS) (dlo a twò cho): dlo spa a make 110°F (43.3°C) sou yon sensè tanperati dlo epi yo…
M033Safety Trip - Pump Suction Blockage* (deklanchman sekirite - blokaj aspirasyon ponp): fèmti vacuum switch la…
M016Heater Flow is Reduced (HFL) (kouran dlo nan chofaj la redui): kouran dlo ki pase nan chofaj la ka twò ba pou…
M017Heater Flow is Reduced (LF)* (kouran dlo nan chofaj la redui): pa gen ase dlo k ap pase nan chofaj la epi…
M028Heater May be Dry (dr)* (chofaj la ka sèk): chofaj la ka sèk, oswa li manke dlo li bezwen pou l limen
M030HTR is too Hot (OHH)* (chofaj la twò cho): chofaj la make 118°F (47.8°C) sou yon sensè tanperati dlo, kidonk…
PRES BTTN TO RSETYon mesaj reset ka parèt bò kote lòt mesaj yo, epi kèk erè mande pou w koupe kouran an epi remete l
M015Sensor Balance is Poor (balans sensè a pa bon): de sensè tanperati yo KA diferan youn de lòt pa 2°F (1.1°C)…
M026Sensor Balance is Poor* (balans sensè a pa bon): sensè tanperati yo DIFERAN
M031Sensor Failure - Sensor A (pàn sensè - sensè A): swa yon sensè tanperati swa sikui li kase
M032Sensor Failure - Sensor B (pàn sensè - sensè B): swa yon sensè tanperati swa sikui li kase
NO COMMNo Communications (pa gen kominikasyon): panèl kontwòl la pa resevwa anyen nan sistèm nan
BETA VERSIONPre-Production Software (lojisyèl anvan pwodiksyon): sistèm kontwòl la ap mache ak yon lojisyèl tès
°T°T parèt kote °F oswa °C ta dwe ye a: sistèm kontwòl la nan Test Mode (mòd tès)
M022Memory Failure - Checksum Error* (pàn memwa - erè checksum): lè l fenk resevwa kouran, sistèm nan pa pase…
M021BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panelMemory Warning - Persistent Memory Reset* (avètisman memwa - reyinisyalizasyon memwa pèmanan): li parèt apre…
M021BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panelYo reyinisyalize paramèt yo (mesaj PERSISTENT MEMORY ERROR a)*
M020BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panelMemory Failure - Clock Error* (pàn memwa - erè revèy) (sa pa aplike sou BP1500 la)
M020BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panelTHE CLOCK HAS FAILED* (revèy la pa mache)
CNFG FAILConfiguration Error (erè konfigirasyon) - spa a pa pral kòmanse
M036GFCI Failure (pàn GFCI) - sistèm nan pa t kapab teste oswa deklanche GFCI a (Amerik di Nò sèlman)
M034Yon ponp sanble kole sou ON, e dlo a ka ap surchofe
M035Yon ponp sanble te kole sou ON dènye fwa spa a te resevwa kouran
M027THE HEATER IS DRY* (chofaj la sèk): chofaj la manke dlo li bezwen pou l limen, epi spa a fèmen
WATER TEMPERATURE IS UNKNOWNTanperati dlo a parèt lè ponp lan fin mache pandan 1 minit
POSSIBLE FREEZING CONDITIONYo detekte yon posib kondisyon frizè, oswa Aux Freeze Switch la fèmen
COMMUNICATIONS ERRORPanèl kontwòl la pa resevwa anyen nan sistèm nan
TEST SOFTWARE INSTALLEDSistèm kontwòl la ap mache ak yon lojisyèl tès
CONFIGURATION ERRORErè konfigirasyon - spa a pa pral kòmanse
SaMesaj erè Sa sou bò spa a: sa montre yon sensè ki pa bon (Sensor A, M7 sensor set sou J16/J17) oswa petèt yon…
SbMesaj erè Sb sou bò spa a: sa montre yon sensè ki pa bon (Sensor B, M7 sensor set sou J16/J17) oswa petèt yon…
FLOSistèm chofaj Low Flow yo montre erè FLO sou ekran anwo a lè sòti ponp lan twò fèb oswa filtè a sal

M019 Priming Mode: li antre chak fwa yo mete kouran pandan 4 minit pou itilizatè a ka mache chak ponp epi verifye…

Ekran an montre: RUN PMPS PURG AIR (PRIMING MODE - M019) (mache ponp yo, retire lè a - mòd amòsaj)

Sa li vle di

Priming Mode: li antre chak fwa yo mete kouran pandan 4 minit pou itilizatè a ka mache chak ponp epi verifye l amòse (lè a retire) e dlo a ap koule; yo pa pèmèt chofaj la mache. Yon Circ Pump mache ak Jets 1 epi li mache poukont li apre Priming Mode.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Mache chak ponp epi tcheke si dlo a ap koule
  2. Soti bonè lè w peze nenpòt bouton Temp

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

TOO COLD Too Cold - Freeze Protection (twò frèt - pwoteksyon kont frizè): sistèm nan santi yon frizè posib, oswa Aux…

Ekran an montre: 42°F TOO COLD (twò frèt)

Sa li vle di

Too Cold - Freeze Protection (twò frèt - pwoteksyon kont frizè): sistèm nan santi yon frizè posib, oswa Aux Freeze Switch la fèmen. Tout ponp yo ak blower a rete limen pandan 4 minit omwen apre sa pase. Sa a se yon mesaj estati, se pa yon erè.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M029 Water is too Hot (OHS) (dlo a twò cho): dlo spa a make 110°F (43.3°C) sou yon sensè tanperati dlo epi yo…

Ekran an montre: WATR TOO HOT (OHS - M029) (dlo a twò cho)

Sa li vle di

Water is too Hot (OHS) (dlo a twò cho): dlo spa a make 110°F (43.3°C) sou yon sensè tanperati dlo epi yo koupe tout fonksyon spa yo. Li reyinisyalize poukont li lè dlo a desann anba 108°F (42.2°C).

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Chèche yon ponp ki mache twò lontan oswa yon tanperati ki cho alantou.
  2. Tann: sistèm nan reyinisyalize poukont li anba 108°F (42.2°C)

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M033 Safety Trip - Pump Suction Blockage* (deklanchman sekirite - blokaj aspirasyon ponp): fèmti vacuum switch la…

Ekran an montre: SFTY TRIP (M033) (deklanchman sekirite)

Sa li vle di

Safety Trip - Pump Suction Blockage* (deklanchman sekirite - blokaj aspirasyon ponp): fèmti vacuum switch la montre yon pwoblèm aspirasyon oswa yo anpeche yon posib antrapman (se pa tout spa ki gen fonksyon sa a).

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M016 Heater Flow is Reduced (HFL) (kouran dlo nan chofaj la redui): kouran dlo ki pase nan chofaj la ka twò ba pou…

Ekran an montre: HTR FLOW LOSS (HFL - M016) (pèt kouran dlo nan chofaj la)

Sa li vle di

Heater Flow is Reduced (HFL) (kouran dlo nan chofaj la redui): kouran dlo ki pase nan chofaj la ka twò ba pou retire chalè sou rezistans lan. Chofaj la kòmanse limen ankò apre apeprè 1 minit.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Verifikasyon kouran dlo: chèche nivo dlo ki ba, aspirasyon ki bouche, valv ki fèmen, lè nan tiyo yo, twòp jè ki fèmen, ak amòsaj ponp lan.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M017 Heater Flow is Reduced (LF)* (kouran dlo nan chofaj la redui): pa gen ase dlo k ap pase nan chofaj la epi…

Ekran an montre: HTR FLOW FAIL (LF - M017) (kouran dlo nan chofaj la echwe)

Sa li vle di

Heater Flow is Reduced (LF)* (kouran dlo nan chofaj la redui): pa gen ase dlo k ap pase nan chofaj la epi chofaj la dezaktive.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Verifikasyon kouran dlo: chèche nivo dlo ki ba, aspirasyon ki bouche, valv ki fèmen, lè nan tiyo yo, twòp jè ki fèmen, ak amòsaj ponp lan.
  2. Lè ou fin repare kòz la, peze nenpòt bouton pou reyinisyalize epi kite chofaj la limen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M028 Heater May be Dry (dr)* (chofaj la ka sèk): chofaj la ka sèk, oswa li manke dlo li bezwen pou l limen

Ekran an montre: HTR MAY BE DRY - WAIT (dr - M028) (chofaj la ka sèk - tann)

Sa li vle di

Heater May be Dry (dr)* (chofaj la ka sèk): chofaj la ka sèk, oswa li manke dlo li bezwen pou l limen. Spa a fèmen pandan 15 minit.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Verifikasyon kouran dlo: chèche nivo dlo ki ba, aspirasyon ki bouche, valv ki fèmen, lè nan tiyo yo, twòp jè ki fèmen, ak amòsaj ponp lan.
  2. Peze nenpòt bouton pou reyinisyalize limen chofaj la.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

M030 HTR is too Hot (OHH)* (chofaj la twò cho): chofaj la make 118°F (47.8°C) sou yon sensè tanperati dlo, kidonk…

Ekran an montre: HTR TOO HOT (OHH - M030) (chofaj la twò cho)

Sa li vle di

HTR is too Hot (OHH)* (chofaj la twò cho): chofaj la make 118°F (47.8°C) sou yon sensè tanperati dlo, kidonk spa a fèmen.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Lè dlo a anba 108°F (42.2°C), peze nenpòt bouton pou reyinisyalize.
  2. Verifikasyon kouran dlo: chèche nivo dlo ki ba, aspirasyon ki bouche, valv ki fèmen, lè nan tiyo yo, twòp jè ki fèmen, ak amòsaj ponp lan.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 68. manyèl faktori a (PDF)

Mande Blue gratisBay teknisyen ou yo Blue

PRES BTTN TO RSET Yon mesaj reset ka parèt bò kote lòt mesaj yo, epi kèk erè mande pou w koupe kouran an epi remete l

Sa li vle di

Yon mesaj reset ka parèt bò kote lòt mesaj yo, epi kèk erè mande pou w koupe kouran an epi remete l.

Sa pou w tcheke, youn apre lòt

  1. Peze yon bouton pou reyinisyalize
  2. Si sa nesesè, koupe kouran an epi remete l

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M015 Sensor Balance is Poor (balans sensè a pa bon): de sensè tanperati yo KA diferan youn de lòt pa 2°F (1.1°C)…

Ekran an montre: SNSR BALANCE (M015) (balans sensè)

Sa li vle di

Sensor Balance is Poor (balans sensè a pa bon): de sensè tanperati yo KA diferan youn de lòt pa 2°F (1.1°C) oswa 3°F (1.7°C).

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M026 Sensor Balance is Poor* (balans sensè a pa bon): sensè tanperati yo DIFERAN

Ekran an montre: SNSR SYNC - CALL FOR SRVC (M026) (sensè yo pa dakò - rele sèvis)

Sa li vle di

Sensor Balance is Poor* (balans sensè a pa bon): sensè tanperati yo DIFERAN; pwoblèm Sensor Balance is Poor sa a la depi 1 èdtan oswa plis.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Rele pou sèvis

Ki lè pou w rele yon teknisyen: Pi gwo konsèy faktori a bay pou kòd sa a se pou yon teknisyen ki kalifye tcheke aparèy la.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M031 Sensor Failure - Sensor A (pàn sensè - sensè A): swa yon sensè tanperati swa sikui li kase

Ekran an montre: SNSR A - CALL FOR SRVC (M031) (sensè A - rele sèvis)

Sa li vle di

Sensor Failure - Sensor A (pàn sensè - sensè A): swa yon sensè tanperati swa sikui li kase.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Rele pou sèvis

Ki lè pou w rele yon teknisyen: Pi gwo konsèy faktori a bay pou kòd sa a se pou yon teknisyen ki kalifye tcheke aparèy la.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M032 Sensor Failure - Sensor B (pàn sensè - sensè B): swa yon sensè tanperati swa sikui li kase

Ekran an montre: SNSR B - CALL FOR SRVC (M032) (sensè B - rele sèvis)

Sa li vle di

Sensor Failure - Sensor B (pàn sensè - sensè B): swa yon sensè tanperati swa sikui li kase.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Rele pou sèvis

Ki lè pou w rele yon teknisyen: Pi gwo konsèy faktori a bay pou kòd sa a se pou yon teknisyen ki kalifye tcheke aparèy la.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

NO COMM No Communications (pa gen kominikasyon): panèl kontwòl la pa resevwa anyen nan sistèm nan

Sa li vle di

No Communications (pa gen kominikasyon): panèl kontwòl la pa resevwa anyen nan sistèm nan.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

BETA VERSION Pre-Production Software (lojisyèl anvan pwodiksyon): sistèm kontwòl la ap mache ak yon lojisyèl tès

Sa li vle di

Pre-Production Software (lojisyèl anvan pwodiksyon): sistèm kontwòl la ap mache ak yon lojisyèl tès.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

°T °T parèt kote °F oswa °C ta dwe ye a: sistèm kontwòl la nan Test Mode (mòd tès)

Ekran an montre: 102°T

Sa li vle di

°T parèt kote °F oswa °C ta dwe ye a: sistèm kontwòl la nan Test Mode (mòd tès).

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M022 Memory Failure - Checksum Error* (pàn memwa - erè checksum): lè l fenk resevwa kouran, sistèm nan pa pase…

Ekran an montre: MEM FAIL (M022) (pàn memwa)

Sa li vle di

Memory Failure - Checksum Error* (pàn memwa - erè checksum): lè l fenk resevwa kouran, sistèm nan pa pase Program Checksum Test la - yon pwoblèm ak firmware a (pwogram fonksyònman an).

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Fò yon teknisyen vin fè sèvis

Ki lè pou w rele yon teknisyen: Pi gwo konsèy faktori a bay pou kòd sa a se pou yon teknisyen ki kalifye tcheke aparèy la.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M021 Memory Warning - Persistent Memory Reset* (avètisman memwa - reyinisyalizasyon memwa pèmanan): li parèt apre…

Sou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel

Ekran an montre: MEM RSET (M021) (reyinisyalizasyon memwa)

Sa li vle di

Memory Warning - Persistent Memory Reset* (avètisman memwa - reyinisyalizasyon memwa pèmanan): li parèt apre nenpòt chanjman nan konfigirasyon sistèm nan.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Rele reprezantan w oswa konpayi sèvis la si li parèt sou plizyè mete kouran, oswa apre sistèm nan fin mache nòmalman pandan yon bon moman.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M021 Yo reyinisyalize paramèt yo (mesaj PERSISTENT MEMORY ERROR a)*

Sou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel

Ekran an montre: THE SETTINGS HAVE BEEN RESET (PERSISTENT MEMORY ERROR)* - M021 (paramèt yo reyinisyalize - erè memwa pèmanan)

Sa li vle di

Yo reyinisyalize paramèt yo (mesaj PERSISTENT MEMORY ERROR a)*.

Sa pou w tcheke, youn apre lòt

  1. Rele reprezantan w oswa konpayi sèvis la si mesaj sa a parèt apre plis pase yon fwa w mete kouran.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

M020 Memory Failure - Clock Error* (pàn memwa - erè revèy) (sa pa aplike sou BP1500 la)

Sou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel

Ekran an montre: CLOK FAIL (M020) (pàn revèy)

Sa li vle di

Memory Failure - Clock Error* (pàn memwa - erè revèy) (sa pa aplike sou BP1500 la).

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M020 THE CLOCK HAS FAILED* (revèy la pa mache)

Sou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel

Ekran an montre: THE CLOCK HAS FAILED* - M020 (revèy la pa mache)

Sa li vle di

THE CLOCK HAS FAILED* (revèy la pa mache).

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

CNFG FAIL Configuration Error (erè konfigirasyon) - spa a pa pral kòmanse

Sa li vle di

Configuration Error (erè konfigirasyon) - spa a pa pral kòmanse.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M036 GFCI Failure (pàn GFCI) - sistèm nan pa t kapab teste oswa deklanche GFCI a (Amerik di Nò sèlman)

Ekran an montre: GFCI FAIL (M036) (pàn GFCI)

Sa li vle di

GFCI Failure (pàn GFCI) - sistèm nan pa t kapab teste oswa deklanche GFCI a (Amerik di Nò sèlman). Enstalasyon an ka pa an sekirite.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M034 Yon ponp sanble kole sou ON, e dlo a ka ap surchofe

Ekran an montre: STUK PUMP (M034) (ponp kole)

Sa li vle di

Yon ponp sanble kole sou ON, e dlo a ka ap surchofe.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Koupe kouran spa a
  2. Pa antre nan dlo a

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M035 Yon ponp sanble te kole sou ON dènye fwa spa a te resevwa kouran

Ekran an montre: HOT FALT - CALL FOR SRVC (M035) (pwoblèm chalè - rele sèvis)

Sa li vle di

Yon ponp sanble te kole sou ON dènye fwa spa a te resevwa kouran.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Koupe kouran spa a
  2. Pa antre nan dlo a
  3. Rele pou sèvis

Ki lè pou w rele yon teknisyen: Pi gwo konsèy faktori a bay pou kòd sa a se pou yon teknisyen ki kalifye tcheke aparèy la.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP400 / TP600 panel, BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 69. manyèl faktori a (PDF)

M027 THE HEATER IS DRY* (chofaj la sèk): chofaj la manke dlo li bezwen pou l limen, epi spa a fèmen

Ekran an montre: THE HEATER IS DRY* - M027 (chofaj la sèk)

Sa li vle di

THE HEATER IS DRY* (chofaj la sèk): chofaj la manke dlo li bezwen pou l limen, epi spa a fèmen.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Verifikasyon kouran dlo: chèche nivo dlo ki ba, aspirasyon ki bouche, valv ki fèmen, lè nan tiyo yo, twòp jè ki fèmen, ak amòsaj ponp lan.
  2. Lè ou fin repare kòz la, efase mesaj la pou limen chofaj la ka rekòmanse.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 59. manyèl faktori a (PDF)

WATER TEMPERATURE IS UNKNOWN Tanperati dlo a parèt lè ponp lan fin mache pandan 1 minit

Ekran an montre: WATER TEMPERATURE IS UNKNOWN (---°F / ---°C) (tanperati dlo a pa konnen)

Sa li vle di

Tanperati dlo a parèt lè ponp lan fin mache pandan 1 minit.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

POSSIBLE FREEZING CONDITION Yo detekte yon posib kondisyon frizè, oswa Aux Freeze Switch la fèmen

Sa li vle di

Yo detekte yon posib kondisyon frizè, oswa Aux Freeze Switch la fèmen; tout aparèy dlo yo aktive. Se yon mesaj fonksyònman, se pa yon erè.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

COMMUNICATIONS ERROR Panèl kontwòl la pa resevwa anyen nan sistèm nan

Sa li vle di

Panèl kontwòl la pa resevwa anyen nan sistèm nan.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

TEST SOFTWARE INSTALLED Sistèm kontwòl la ap mache ak yon lojisyèl tès

Sa li vle di

Sistèm kontwòl la ap mache ak yon lojisyèl tès.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

CONFIGURATION ERROR Erè konfigirasyon - spa a pa pral kòmanse

Ekran an montre: CONFIGURATION ERROR - SPA WILL NOT START UP (erè konfigirasyon - spa a pa pral kòmanse)

Sa li vle di

Erè konfigirasyon - spa a pa pral kòmanse.

Sa pou w tcheke, youn apre lòt

Faktori a pa bay etap reparasyon pou mesaj sa a; li jis montre nan ki eta ekipman an ye. Si li pa efase pou kont li, gade pi ba a ki lè pou w rele yon teknisyen.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: BP500 / BP2000G1 (BP-series spa control systems) with TP800 / TP900 panel
Sous: manyèl depannaj ak sèvis Balboa (42211 C), paj 62. manyèl faktori a (PDF)

Sa Mesaj erè Sa sou bò spa a: sa montre yon sensè ki pa bon (Sensor A, M7 sensor set sou J16/J17) oswa petèt yon…

Ekran an montre: Sa (spaside error message) (mesaj erè sou bò spa a)

Sa li vle di

Mesaj erè Sa sou bò spa a: sa montre yon sensè ki pa bon (Sensor A, M7 sensor set sou J16/J17) oswa petèt yon kat sikui ki pa bon.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Tcheke fil sensè yo pou wè si gen fant oswa domaj (sa ka montre yon rat te manje yo)
  2. Gade de plòg sensè yo sou kat sikui a; yo dwe pwòp.
  3. Avèk kouran an koupe, chanje plas de sensè yo sou kat sikui a (priz Sen. A ak Sen. B) epi remete kouran
  4. Si mesaj la rete menm jan an (toujou Sa, pa egzanp), kat sikui a pa bon. Si li chanje (Sa vin Sb), ranplase sensè a nan plòg ki koresponn lan.

Ki lè pou w rele yon teknisyen: Ou ka fè tchèk ki senp yo poukont ou (kouran, kouran dlo a, filtè, valv ak paramèt). Tout sa ki gen pou wè ak kat kontwòl yo se travay pou yon teknisyen ki kalifye.

Pou: Water Pro BP7 Series (Balboa BP7 system board) - BP7 with Fixed Heater, Remote Heater, Low Flow Heater, BP2000 Series spa control system (Balboa BP2000, Hydro-Quip BP Series kit)
Sous: manyèl enstalasyon/operasyon Balboa (85-0080C Rev.06 02/26), paj 29. manyèl faktori a (PDF) Menm kòd la parèt tou nan 2 lòt manyèl oswa revizyon.

Sb Mesaj erè Sb sou bò spa a: sa montre yon sensè ki pa bon (Sensor B, M7 sensor set sou J16/J17) oswa petèt yon…

Ekran an montre: Sb (spaside error message) (mesaj erè sou bò spa a)

Sa li vle di

Mesaj erè Sb sou bò spa a: sa montre yon sensè ki pa bon (Sensor B, M7 sensor set sou J16/J17) oswa petèt yon kat sikui ki pa bon.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Tcheke fil sensè yo pou wè si gen fant oswa domaj (sa ka montre yon rat te manje yo)
  2. Gade de plòg sensè yo sou kat sikui a; yo dwe pwòp.
  3. Avèk kouran an koupe, chanje plas de sensè yo sou kat sikui a (priz Sen. A ak Sen. B) epi remete kouran
  4. Si mesaj la rete menm jan an (toujou Sa, pa egzanp), kat sikui a pa bon. Si li chanje (Sa vin Sb), ranplase sensè a nan plòg ki koresponn lan.

Ki lè pou w rele yon teknisyen: Ou ka fè tchèk ki senp yo poukont ou (kouran, kouran dlo a, filtè, valv ak paramèt). Tout sa ki gen pou wè ak kat kontwòl yo se travay pou yon teknisyen ki kalifye.

Pou: Water Pro BP7 Series (Balboa BP7 system board) - BP7 with Fixed Heater, Remote Heater, Low Flow Heater, BP2000 Series spa control system (Balboa BP2000, Hydro-Quip BP Series kit)
Sous: manyèl enstalasyon/operasyon Balboa (85-0080C Rev.06 02/26), paj 29. manyèl faktori a (PDF) Menm kòd la parèt tou nan 2 lòt manyèl oswa revizyon.

FLO Sistèm chofaj Low Flow yo montre erè FLO sou ekran anwo a lè sòti ponp lan twò fèb oswa filtè a sal

Ekran an montre: FLO (topside display, Low Flow heater) (ekran anwo a, chofaj Low Flow)

Sa li vle di

Sistèm chofaj Low Flow yo montre erè FLO sou ekran anwo a lè sòti ponp lan twò fèb oswa filtè a sal. Chofaj sa a (Low Flow) bezwen 10-15 GPM (57 L/min) omwen, ki antre pa pò anba a.

Kòz ki pi souvan

Sa pou w tcheke, youn apre lòt

  1. Enstale yon nouvo katouch filtè epi verifye sòti ponp sikilasyon low flow lan
  2. Sèvi ak yon ponp apwouve: Laing/Xylem E10, yon Grundfos 43SPA oswa seri RUES, oswa yon seri LX WE10. Mande founisè w la si ou pa sèten.

Ki lè pou w rele yon teknisyen: Si tchèk sa yo pa rezoud li, oswa si kòd la toujou ap tounen, mande yon teknisyen pisin vin gade ekipman an.

Pou: Water Pro BP7 with Low Flow Heater (Balboa BP7 system board)
Sous: manyèl enstalasyon/operasyon Balboa (85-0080C Rev.06 02/26), paj 15. manyèl faktori a (PDF) Menm kòd la parèt tou nan 1 lòt manyèl oswa revizyon.

Blue konnen chak kòd ak manyèl modèl egzak ou a

Mande Blue gratis nan app Pool AI a: di Blue kòd la ak modèl ou, epi l ap ba w etap yo pou ekipman ou.

Mande Blue gratis

Ou gen yon konpayi pisin? Bay teknisyen ou yo Blue: chak kòd, chak manyèl ak ekipman kliyan ou yo nan yon sèl app.

Bay teknisyen ou yo Blue

Kesyon

Kisa kòd Sa Balboa la vle di (sistèm spa seri BP (BP500, BP2000, BP7))?

Mesaj erè Sa sou bò spa a: sa montre yon sensè ki pa bon (Sensor A, M7 sensor set sou J16/J17) oswa petèt yon kat sikui ki pa bon. Premye bagay pou w tcheke: Tcheke fil sensè yo pou wè si gen fant oswa domaj (sa ka montre yon rat te manje yo).

Kisa kòd Sb Balboa la vle di (sistèm spa seri BP (BP500, BP2000, BP7))?

Mesaj erè Sb sou bò spa a: sa montre yon sensè ki pa bon (Sensor B, M7 sensor set sou J16/J17) oswa petèt yon kat sikui ki pa bon. Premye bagay pou w tcheke: Tcheke fil sensè yo pou wè si gen fant oswa domaj (sa ka montre yon rat te manje yo).

Kisa kòd FLO Balboa la vle di (sistèm spa seri BP (BP500, BP2000, BP7))?

Sistèm chofaj Low Flow yo montre erè FLO sou ekran anwo a lè sòti ponp lan twò fèb oswa filtè a sal. Chofaj sa a (Low Flow) bezwen 10-15 GPM (57 L/min) omwen, ki antre pa pò anba a. Premye bagay pou w tcheke: Enstale yon nouvo katouch filtè epi verifye sòti ponp sikilasyon low flow lan.

Kisa kòd M019 Balboa la vle di (sistèm spa seri BP (BP500, BP2000, BP7))?

Priming Mode: li antre chak fwa yo mete kouran pandan 4 minit pou itilizatè a ka mache chak ponp epi verifye l amòse (lè a retire) e dlo a ap koule; yo pa pèmèt chofaj la mache. Yon Circ Pump mache ak Jets 1 epi li mache poukont li apre Priming Mode. Premye bagay pou w tcheke: Mache chak ponp epi tcheke si dlo a ap koule.

Kisa kòd TOO COLD Balboa la vle di (sistèm spa seri BP (BP500, BP2000, BP7))?

Too Cold - Freeze Protection (twò frèt - pwoteksyon kont frizè): sistèm nan santi yon frizè posib, oswa Aux Freeze Switch la fèmen. Tout ponp yo ak blower a rete limen pandan 4 minit omwen apre sa pase. Sa a se yon mesaj estati, se pa yon erè.

Lòt paj ki gen rapò

Enfòmasyon jeneral ki soti nan manyèl faktori yo, nou ekri l ak pwòp mo pa nou. Pool AI pa afilye ak mak yo nonmen la a, ni yo pa apwouve li; non mak ak modèl yo se pou mèt yo. Toujou swiv manyèl modèl egzak ou a ak règleman lokal yo. Se sèlman moun ki kalifye e ki gen lisans ki dwe travay sou gaz, gwo vòltaj ak refrijeran. Mete ajou 2026-11-23.