| Code | What it means |
|---|---|
| DISPLAY BLANK | The ChlorSync display is blank (no power to the unit) |
| SALT LED FLASHING GREEN | Salt is over 5,000 ppm (mg/L) |
| Lo SALt | Salt is low, at 2,300-2,700 ppm (mg/L) |
| Add SALt | Salt has fallen under 2,300 ppm (mg/L), which is too low, so chlorine generation has stopped |
| CELL | The unit is not making chlorine and the cell needs a check |
| no FLo | The flow sensor reads low (not enough) water flow through the cell, and the unit will not make chlorine… |
| NO POWER | The ChlorSync unit does not have power |
DISPLAY BLANK The ChlorSync display is blank (no power to the unit)
Display shows: Display is Blank
What it means
The ChlorSync display is blank (no power to the unit).
Common causes
- No power to the power supply
- Incorrect transformer wiring for the incoming voltage
- Failed 10A fuse
- The transformer or the power supply circuit board has a problem.
What to check, in order
- Check the circuit breaker. If it is wired through a time clock, make sure the clock is on.
- Confirm the transformer is wired properly for the incoming voltage
- Test the 10A fuse and replace as necessary
- Contact your nearest service center or AquaCal AutoPilot Customer Support about the transformer / power supply board problem.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 29. maker's manual (PDF)
SALT LED FLASHING GREEN Salt is over 5,000 ppm (mg/L)
Display shows: Salt indicator Green LED (flashing)
What it means
Salt is over 5,000 ppm (mg/L). The unit keeps making chlorine and high salt will not harm it.
Common causes
- Salt level above 5,000 ppm (mg/L)
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 12. maker's manual (PDF)
Lo SALt Salt is low, at 2,300-2,700 ppm (mg/L)
Display shows: "Lo SALt" message is displayed / Salt LED is solid red
What it means
Salt is low, at 2,300-2,700 ppm (mg/L). The unit still makes chlorine, but at reduced output.
Common causes
- Salt level between 2,300 and 2,700 ppm (mg/L)
What to check, in order
- Test the salt level with salt test strips or have the water tested by a local pool professional
- Raise salt to 3,500 ppm (mg/L). Recommended is 3,500 - 4,500 ppm (mg/L), with 2,300 ppm as the minimum.
- Run the circulation pump continuously until the salt is fully dissolved, then reset power to the power supply for an accurate new salt reading
- With the PoolSync option, consult the PoolSync app
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 30. maker's manual (PDF)
Add SALt Salt has fallen under 2,300 ppm (mg/L), which is too low, so chlorine generation has stopped
Display shows: "Add SALt" message is displayed / Salt LED is flashing red
What it means
Salt has fallen under 2,300 ppm (mg/L), which is too low, so chlorine generation has stopped.
Common causes
- Salt level below 2,300 ppm (mg/L)
What to check, in order
- Test the salt level with salt test strips or have the water tested by a local pool professional
- Raise salt to 3,500 ppm (mg/L). Recommended is 3,500 - 4,500 ppm (mg/L), with 2,300 ppm as the minimum.
- Run the circulation pump continuously until the salt is fully dissolved, then reset power to the power supply for an accurate new salt reading
- With the PoolSync option, consult the PoolSync app
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 30. maker's manual (PDF)
CELL The unit is not making chlorine and the cell needs a check
Display shows: Cell LED is flashing red. Display shows "CELL"
What it means
The unit is not making chlorine and the cell needs a check. Calcium on the blades, low salt and similar causes can reduce conductivity.
Common causes
- Dirty cell or calcium build up
- Low salt level
- Pool/spa water chemistry not balanced
- Salt added recently (not yet diluted)
What to check, in order
- Inspect and clean the cell as appropriate (see Cleaning the Cell: garden hose, then AutoPilot Acid Wash Kit)
- Look at the salt indicator LED and the display for any error messages.
- Contact a local pool professional and take the necessary steps to balance the water
- If salt was added recently, wait 24 hours for it to be completely diluted
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 30. maker's manual (PDF)
no FLo The flow sensor reads low (not enough) water flow through the cell, and the unit will not make chlorine…
Display shows: Flow LED is flashing red (display shows "no FLo")
What it means
The flow sensor reads low (not enough) water flow through the cell, and the unit will not make chlorine without flow.
Common causes
- Insufficient water flow
- Possible flow switch failure
What to check, in order
- Make sure the circulation pump runs. On a variable speed pump, choose an RPM that delivers at least 20 gpm (76 L/min) to the cell.
- Check the pump strainer basket and clear debris
- Confirm all valves are aligned correctly (valves may be closed)
- Check the pool/spa filter and clean it if needed.
- Inspect and clean the cell for an obstruction
- A failed flow switch should be checked by an AutoPilot service representative near you, or by AquaCal AutoPilot Customer Support.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 31. maker's manual (PDF)
NO POWER The ChlorSync unit does not have power
Display shows: ChlorSync unit does not have power
What it means
The ChlorSync unit does not have power.
Common causes
- Failed fuse in the power center
- Power center not receiving proper 110 VAC or 220 VAC
- Transformer leads not wired correctly in the power center
What to check, in order
- Test the power center fuse and replace it when needed.
- Confirm the power center gets the correct 110 VAC or 220 VAC.
- Confirm the transformer is wired correctly (wiring diagram inside the power center cover)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: ChlorSync CS30, ChlorSync CS40, ChlorSync CS50, ECP0312 Power Center
Source: the AutoPilot owner's / installation manual (LTP0127 REV 2.0), page 31. maker's manual (PDF)
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does AutoPilot code DISPLAY BLANK mean on ChlorSync salt chlorinators?
The ChlorSync display is blank (no power to the unit). First check: Check the circuit breaker. If it is wired through a time clock, make sure the clock is on.
What does AutoPilot code SALT LED FLASHING GREEN mean on ChlorSync salt chlorinators?
Salt is over 5,000 ppm (mg/L). The unit keeps making chlorine and high salt will not harm it.
What does AutoPilot code Lo SALt mean on ChlorSync salt chlorinators?
Salt is low, at 2,300-2,700 ppm (mg/L). The unit still makes chlorine, but at reduced output. First check: Test the salt level with salt test strips or have the water tested by a local pool professional.
What does AutoPilot code Add SALt mean on ChlorSync salt chlorinators?
Salt has fallen under 2,300 ppm (mg/L), which is too low, so chlorine generation has stopped. First check: Test the salt level with salt test strips or have the water tested by a local pool professional.
What does AutoPilot code CELL mean on ChlorSync salt chlorinators?
The unit is not making chlorine and the cell needs a check. Calcium on the blades, low salt and similar causes can reduce conductivity. First check: Inspect and clean the cell as appropriate (see Cleaning the Cell: garden hose, then AutoPilot Acid Wash Kit).
Related
- All AutoPilot error codes
- All pool equipment error codes
- Salt system not making chlorine: what to check
- How much chlorine does my pool need?
- Free pool chemical dose calculator
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.