Get Started

Pool codes · District of Columbia

District of Columbia pool rules (25-C DCMR) explained

What the District of Columbia requires at public and semi-public pools, from the official regulation text, in short plain sentences. For condo, co-op, hotel and apartment pool managers, pool service companies, builders and inspectors.

At a glance

  • DC Health regulates public pools under Title 25, Subtitle C of the DC Municipal Regulations, the Aquatic Facilities Regulations (effective 2017-06-09). DC has no counties, so there is no separate local health department. [1]
  • Private single-family pools, used only by the owner or lessee, family and non-paying guests, are outside DC Health's rules. The Department of Buildings permits them. [2]
  • Free chlorine must stay between 1 and 10 mg/L in conventional pools. pH must stay between 7.2 and 7.8. [3]
  • Anyone who maintains water quality at a public pool needs a DC Health Pool and Spa Operator Registration Card, renewed every 3 years. [4]
  • Since 2018, condo, co-op and apartment pools of the semi-public type may skip the DC Health license, the operator and the log requirements. [5]
  1. 25-C DCMR 100-1002 and 9999 (scope 101.5, incorporations 102.1); D.C. Code 7-431 to 7-434 — 25-C DCMR Swimming Pool and Spa Regulations, Chapter 1 Title, Intent, Scope (DCRegs, DC Office of Documents and Administrative Issuances) · checked October 22, 2026
  2. 25-C DCMR 101.5(b); 12-L DCMR 202; 12-A DCMR 105.1, 105.2 (Building item 9), 105.2.5, 105.2.6; 12-A 101.3, 101.13 — Swimming Pool Permit (DC Department of Buildings) · checked October 22, 2026
  3. 25-C DCMR 402.1, 402.6, 403.1, 404.2, 404.4, 406.1 — 25-C DCMR Chapter 4 Water Quality, Circulation Systems, and Reporting Requirements (DCRegs) · checked October 22, 2026
  4. 25-C DCMR 300.1-300.8, 700.4, 704.1-704.2, 9999 (Pool and Spa Operator); D.C. Code 7-434(1) — 25-C DCMR Chapter 3 Training and Certifications, Duties, Facility Postings and Use Restrictions, and Child Safety Plan (DCRegs) · checked October 22, 2026
  5. D.C. Code 7-431 to 7-434 (D.C. Law 22-147, 65 DCR 5988) — Code of the District of Columbia, Title 7, Chapter 4A Semi-public Swimming Pools (DC Council Law Library) · checked October 22, 2026

Who regulates pools

  • The rule is the Aquatic Facilities Regulations: Swimming Pools, Spa Pools, and Saunas (25-C DCMR). It replaced the old 25-C Chapter 64. [1]
  • It covers facility licenses, operator cards, lifeguards, child safety plans, water quality, circulation, equipment rooms, safety equipment, barriers, plan review, inspections, closures and penalties. [1]
  • It incorporates the CDC Model Aquatic Health Code 2nd edition, the federal Virginia Graeme Baker Act, NSF/ANSI 50 and 60, the 2010 ADA Standards and the DC Construction Codes. [1]
  • DC Health's Division of Community Hygiene licenses and inspects pools. The Department of Buildings handles construction permits. [1, 6]
  • Municipal pools run by DC Parks and Recreation are still covered by 25-C. [1]
  • Some citations in 25-C are out of date. It still cites the 2013 DC codes although the 2017 codes are in force, and it still names the old DCRA agency. [1]
  1. 25-C DCMR 600.1-600.3, 700.7, 705.1, 706.1; 12-A DCMR 101.13; 12-L DCMR 101, 202, 406.2 — 12-L DCMR Swimming Pool and Spa Code Supplement of 2017, Chapter 4 Public Swimming Pools (DCRegs) · checked October 22, 2026

Operator and technician certificates

  • A pool and spa operator must be on duty during all hours an aquatic facility is open. [4]
  • Anyone who maintains cleanliness, water quality and chemical balance of a public pool, spa pool or sauna needs a Pool and Spa Operator Registration Card from DC Health. [4]
  • The card comes after a DC Health-approved course covering calculations, filtration, water chemistry, spas, maintenance, safety and the 25-C rules. Cards are renewed every 3 years. [4]
  • The operator definition requires National Swimming Pool Foundation certification plus the DC card. [4]
  • Operators may not delegate work to uncertified staff. The card is not a contractor license. [4]

Water chemistry ranges

Ranges as 25-C 404 states them. Water must come from the DC public water system and be coliform-free.

WhatWhat the rule says
pH7.2 to 7.8 (never below 6.5 or above 8.0) [3]
Free chlorine, conventional pools1 to 10 mg/L (indoor conventional pools: 5 mg/L maximum) [3]
Free chlorine, other pool types2 to 10 mg/L (spa-type pools: 3 mg/L minimum) [3]
Bromine1.5 to 8 mg/L in pools, 4 to 8 mg/L in spa-type pools (indoor conventional pools: 6 mg/L maximum) [3]
Combined chlorine0.4 ppm maximum [3]
Cyanuric acid30 to 50 mg/L, never over 100 ppm in pools and spas [3]
ORP (with a controller)600 to 900 mV [3]
Quaternary ammonium5 mg/L maximum [3]
Turbidity0.5 NTU or less [3]
Spa and heated pool temperature104 F maximum [3]
Total alkalinity, calcium hardnessNo numeric range set (test kits are still required) [3]
  • Reduce combined chlorine by superchlorination or water exchange. [3]
  • When chemicals are added by hand, close the pool before and for at least 1 hour after. After breakpoint or algae treatment, reopen when free chlorine drops to 10 mg/L. [3]
  • Pool chemicals must be NSF/ANSI 60 approved. [3]
  • The spa-type free chlorine wording in the rule is ambiguous. It reads as 3 to 10 mg/L for spas, so confirm with DC Health. [3]

Required tests and how often

  • Test pH, free chlorine and bromine at least every 3 hours. [7]
  • Test cyanuric acid before opening, if it is used. [7]
  • Keep test kits on site for free and total chlorine (DPD) or bromine, total alkalinity, calcium hardness and pH. Add cyanuric acid, salt, quat, ozone or copper kits when you use them. [7]
  • With an ORP controller, manual testing is still required. [3]
  1. 25-C DCMR 405.1-405.4, 412.1-412.7, 202.1(b) — 25-C DCMR Chapter 4 Water Quality, Circulation Systems, and Reporting Requirements (DCRegs) · checked October 22, 2026

Logs and record keeping

  • Daily logs record operators and lifeguards on duty, flow-rate readings, weather, temperature, attendance, backwash or filter-cleaning time, injuries, chemicals added and broken equipment. [7]
  • Log pH, free chlorine and bromine readings taken at least every 3 hours. [7]
  • Make entries at least 3 times a day: before opening, between 12 and 2 p.m., and 2 hours before closing. DC Health may require more. [7]
  • Logs must be readable, dated, signed and kept on site at least 3 years. [7]
  • Spa signs must post the water temperature at 3-hour intervals. [7]
  • A missing test kit or log is a summary-suspension condition. [7]

When a pool must close

  • The operator must stop operations and notify DC Health, or DC Health will summarily suspend the license, when imminent health hazards exist. [8]
  • These include pH below 6.5 or above 8.0, disinfectant outside limits, contaminated water, poor clarity, filtration not running continuously, drain and VGB defects, missing safety equipment, no hot water and cross-connections. [8]
  • DC Health may also suspend for no operator card, no license, missing barriers, no test kit or logs, unreported incidents, overhead wires or missing GFCI within 20 feet, and failed recirculation or chemical feeders. [8]
  • Critical violations must be fixed at inspection, or within the time DC Health agrees to, no more than 5 calendar days. Noncritical violations are fixed within 14 calendar days unless a written schedule is approved. [8]
  • DC Health posts an AQUATIC FACILITY CLOSED sign. Reopening needs DC Health approval. [8]
  • Report to DC Health within 24 hours any death, serious injury, injury needing resuscitation or hospital admission, and any bather illness complaint blamed on the facility. [9]
  • Give DC Health at least 30 calendar days' notice before shutting down a facility, permanently or temporarily. [9]
  1. 25-C DCMR 715.1-715.3, 716.1, 717.1-717.3, 719.1-719.3 — 25-C DCMR Chapter 7 Application and Licensing Requirements, and Definitions (DCRegs) · checked October 22, 2026
  2. 25-C DCMR 413.1-413.3, 708.1, 715.2(j)-(k) — 25-C DCMR Chapter 4 Water Quality, Circulation Systems, and Reporting Requirements (DCRegs) · checked October 22, 2026

Drains and entrapment

  • The rule incorporates the federal Virginia Graeme Baker Act and drain cover standards ASME A112.19.8-2007, ASME A112.19.7 and ASTM F2387. [10]
  • Public, wading and spa pools built without a main-drain collector tank must be retrofitted with one to eliminate direct suction through the main drain. A building permit is needed first. [10]
  • Existing direct-suction pools need ASME A112.19.8-2007 drain covers. Single main drains (other than unblockable) need a safety vacuum release system or similar device. [10]
  • New pools need more than one drain, one or more unblockable drains, or no main drain. [10]
  • Face plates and grates must be secured so tools are needed to remove them. The main drain grate must be visible from the deck. [10]
  • Each drain or VGB violation is an imminent health hazard requiring closure. [10]
  1. 25-C DCMR 102.1(a),(f),(g); 402.1; 408.5-408.11, 408.16-408.19; 503.8; 715.1(k)-(o) — 25-C DCMR Chapter 4 Water Quality, Circulation Systems, and Reporting Requirements (DCRegs) · checked October 22, 2026

Safety equipment

  • Public and semi-public pools need an AED on the deck or in an unlockable room, and a shepherd's hook on a one-piece pole at least 16 feet long. [11]
  • A throwing rope at least 1/4 inch thick, 1.5 times the pool's maximum width or 50 feet (whichever is less), on a Coast Guard-approved ring buoy. [11]
  • Also required: a listed first-aid kit, two cots and two blankets, a backboard with head immobilizer, a bloodborne pathogen kit, and a rescue tube per required lifeguard. [11]
  • A hard-wired phone that dials 911 directly must be inside the enclosure or an adjacent unlockable room. [11]
  • Pools over 50 feet long need a hook and ring on each long side. [11]
  • Sources disagree Lifeguards are not required at pools open only to members, residents and their guests, or lodging guests, unless the pool has a diving board, deep water or 50 percent or more bathers under 15. The regulation and the statute word the depth trigger differently: the regulation says 5 feet or more at non-municipal pools of any age, the statute says greater than 5 feet and only for pools built after June 30, 2018. Confirm with DC Health. [12]
  • Sources disagree Where lifeguards are required, the rule sets 1 lifeguard per 50 bathers. Unguarded pools need a DC Health-approved Child Safety Plan. [12]
  • Chlorine gas is prohibited at newly built facilities and at existing ones undergoing renovation that needs a building permit. [13]
  1. 25-C DCMR 505.1-505.4, 609.1-609.3, 715.1(r) — 25-C DCMR Chapter 5 Equipment, Equipment Room, Storage and Maintenance, and Safety (DCRegs) · checked October 22, 2026
  2. 25-C DCMR 301-305; D.C. Code 7-431(4), 7-432 — 25-C DCMR Chapter 3 Training and Certifications, Duties, Facility Postings and Use Restrictions, and Child Safety Plan (DCRegs) · checked October 22, 2026
  3. 25-C DCMR 400.1, 404.3, 503.18-503.19, 607.3-607.7, 608.1-608.10 — 25-C DCMR Chapter 6 Plumbing Systems, Physical Structure, Design, Accommodations, Facility Maintenance, and Pest Control (DCRegs) · checked October 22, 2026

Fences and barriers

  • Outdoor public pools and spa pools need a continuous fence at least 72 inches high, or another barrier DC Health approves. [14]
  • Gates must be self-closing, self-latching and lockable, with the latch at least 4.5 feet above grade, opening outward away from the pool. [14]
  • Put ASTM F1346-91 safety covers on at the end of the outdoor season, when a pool is out of service over 30 days, or when recirculation fails over 72 hours. [14]
  • Missing barriers or covers are summary-suspension conditions. [14]
  • Guidance / not confirmed Condo, co-op and apartment semi-public pools need not fence a rooftop pool, but DC Health guidance says some other compliant barrier to the roof is still needed. [14, 5]
  • For residential pools, the 2015 International Swimming Pool and Spa Code section 305 applies as published through the DC code. DC also has fence permit and height rules. [15]
  1. 25-C DCMR 610.1-610.11, 505.5; D.C. Code 7-434(4) — 25-C DCMR Chapter 6 Plumbing Systems, Physical Structure, Design, Accommodations, Facility Maintenance, and Pest Control (DCRegs) · checked October 22, 2026
  2. 12-A DCMR 101.13; 12-L DCMR 101, 202, 406.2; 12-A DCMR 3112.1-3112.4 — 12-L DCMR Swimming Pool and Spa Code Supplement of 2017, Chapter 1 Scope and Administration (DCRegs) · checked October 22, 2026

Signs and depth markers

  • A "Pool Rules" sign with 3-inch heading letters lists bather load, hours, showering and deck rules. It names the operator and the District permit number. [16, 4]
  • Without a lifeguard, signs warn that no lifeguard is on duty and that children under 15 need adult supervision. [16]
  • Pools of 200 sq ft or more without a diving well post "NO DIVING" in 4-inch letters. Pools 5 feet deep or less show no-diving symbols at intervals of no more than 25 feet. [16]
  • Depth markers are at least 4 inches. [16]
  • Spa and sauna signs include a 104 F limit and a 10 to 15 minute limit. A clock must be visible. [16]
  • Post licenses, inspection results and certifications near the entrance. [17]
  1. 25-C DCMR 102.1(d), 200.5-200.7, 201.1-201.6, 202.1-202.2, 402.3-402.5, 304.1 — 25-C DCMR Chapter 2 General Provisions (DCRegs) · checked October 22, 2026
  2. 25-C DCMR 700.1-700.7, 701.1-701.6, 702.1-702.4, 705.1, 706.1-706.2, 707.1-707.2, 708.2, 709.1 — 25-C DCMR Chapter 7 Application and Licensing Requirements, and Definitions (DCRegs) · checked October 22, 2026

Permits and inspections

  • No one may own, operate or manage a public pool, spa pool or sauna without a DC Health license and a current Certificate of Occupancy. [17]
  • Building or renovating needs written approval of the building agency (now the Department of Buildings) and DC Health. DC Health reviews plans within 30 days. [17]
  • Apply at least 30 days before opening a new facility and 30 days before a license expires. Licenses are not transferable. [17]
  • The application includes the Certificate of Occupancy, plans, a passing preoperational inspection, operator cards, lifeguard certificates and the licensed pest contractor. [17]
  • Licensed indoor pools get two unannounced routine inspections. Seasonal outdoor pools get a mandatory pre-opening inspection, requested in writing at least 30 days ahead, plus one unannounced inspection. [18]
  • Inspectors may enter any part of the facility and examine equipment, chemicals, water samples and records. Inspection reports are public. [18]
  • License and operator-card fees are not stated in 25-C. Ask DC Health. [17]
  1. 25-C DCMR 710.1-710.7, 711.1, 712.1, 714.1-714.3, 720 — 25-C DCMR Chapter 7 Application and Licensing Requirements, and Definitions (DCRegs) · checked October 22, 2026

Local programs and differences

  • DC has no counties. DC Health, the Department of Buildings, the Department of Licensing and Consumer Protection, the Department of Energy and Environment and DC Water are the regulators. [19]
  1. 12-A DCMR 101.1 (2017 codes); Mayor's Orders 2026-021 and 2026-022 (as described by DOB) — DC Department of Buildings Advances Modernization of District Construction Codes (DOB release, June 8, 2026) · checked October 22, 2026

Other things to know

  • Under the Pools Without Penalties Act (D.C. Code 7-431 to 7-434), a condo, co-op or apartment building with a semi-public pool is not required to provide an operator, keep the 25-C log information or get a DC Health facility license. [5]
  • Such pools also need not provide a safety line or fence a rooftop pool. DC Health guidance says it does not inspect unlicensed pools, and they must post a notice that they are not licensed. [5]
  • Guidance / not confirmed Child Safety Plans are still required without a lifeguard. [5]
  • Residential pool permits come from the Department of Buildings, based on architectural plans, a site plan, a surveyor's plat and a water riser diagram. [2]
  • Prefabricated above-ground pools under 24 inches deep, at most 1,000 gallons and not connected to a circulation system need no permit, except in historic districts or flood hazard areas. [2]
  • Residential pool work (contracts of $300 or more) needs a DLCP Home Improvement Contractor license, a $25,000 bond and liability insurance. [20]
  • No pool-specific contractor license exists in DC. Electrical, plumbing and gas work stays with DC-licensed tradespeople. [21, 22]
  • Guidance / not confirmed Chlorinated pool water may not go into storm drains. Drain to the sanitary or combined sewer, or reduce chlorine below 0.1 mg/L first. Fines start at up to $1,000 and double for repeat offenses. [23]
  • Public pool backwash and drain water must go to a sanitary sewer through an approved air gap. [24]
  • Chemical storage must be lockable, with continuous exhaust ventilation, posted Safety Data Sheets and the sign "DANGER - CHEMICAL STORAGE AREA - DO NOT ENTER". [13]
  • Scheduled change The 2017 DC Construction Codes (2015 ICC codes, 2014 NEC) are still current. The Department of Buildings plans new codes on 2024 editions, with final rules expected winter 2027. [19]
  1. 16 DCMR 800.1-800.7, 801, 802.1-802.10, 803.1-803.4, 899.1 — 16 DCMR Chapter 8 Home Improvements (DCRegs) · checked October 22, 2026
  2. 16 DCMR 899.1 (definition of home improvement work); 17 DCMR Chapter 39 (as referenced); 25-C DCMR 300.6 — Contractor and Construction Services (DC Department of Licensing and Consumer Protection) · checked October 22, 2026
  3. 12-A DCMR 101.1, 101.4, 101.5, 105.1.1; 12-C DCMR (Articles 90, 210, 408, 690, 691) — 12-C DCMR Electrical Code Supplement of 2017, Article 90 (DCRegs) · checked October 22, 2026
  4. DOEE guidance citing the DC Water Pollution Control Act and federal Clean Water Act — How to Drain Your Swimming Pool Properly (DC Department of Energy and Environment) · checked October 22, 2026
  5. 25-C DCMR 407.1-407.2, 411.1-411.3, 601.1, 715.1(s); 12-A DCMR 101.7 (DC Plumbing Code 2017 = IPC 2015 + 12-F) — 25-C DCMR Chapter 4 Water Quality, Circulation Systems, and Reporting Requirements (DCRegs) · checked October 22, 2026

Questions people ask

Does DC require a certified pool operator?

Yes. Anyone who maintains water quality at a public pool, spa pool or sauna needs a DC Health Pool and Spa Operator Registration Card, renewed every 3 years. An operator must be on duty whenever the facility is open. [4]

What chlorine and pH levels does DC require?

pH 7.2 to 7.8, and never below 6.5 or above 8.0. Free chlorine 1 to 10 mg/L in conventional pools. Combined chlorine 0.4 ppm maximum. [3]

How long must DC pool logs be kept?

At least 3 years, on site. Logs are dated and signed, with entries at least 3 times a day. [7]

Do condo and apartment pools in DC need a DC Health license?

Not if the building elects the Pools Without Penalties Act for its semi-public pool. DC Health then does not inspect the pool, and it must post a notice that it is not licensed. [5]

Who permits a home pool in DC?

The Department of Buildings issues a swimming pool permit. DC Health does not license private single-family pools. [2]

Keep the records these rules ask for

  • Pool AI saves the readings and the chemicals added at every visit, with the date and the technician.
  • Commercial customers (condos, HOAs, hotels, apartments) can download their chemical log as a PDF or a spreadsheet from their own pool page.
  • Alerts when a reading leaves the range you set, and certificates for your team with renewal reminders.

Questions about a code or a reading? Blue, the free Pool AI assistant, answers pool questions in six languages.

Related pages