Get Started

Pool codes · Illinois

Illinois pool rules (77 IAC 820) explained

What Illinois requires at public and semi-public pools, from the official rule text, in short plain sentences. For condo, HOA, hotel and apartment pool managers, pool service companies, builders and inspectors.

At a glance

  • The Illinois Department of Public Health (IDPH) regulates public pools under the Swimming Facility Code, 77 Ill. Adm. Code 820. Certified local health departments can act as IDPH agents. [1]
  • Pools at apartments, condos and associations with 5 or more living units are covered. Pools at private single-family homes are not. [1]
  • Free chlorine must stay between 1.0 and 4.0 ppm and pH between 7.2 and 7.6. [2]
  • Test disinfectant and pH at least twice daily and record operating data daily. Keep the records at the facility for at least 3 years. [2, 3]
  • Illinois has no statewide certified pool operator rule. Each facility must name a manager/operator responsible for following Part 820. [3]
  1. 77 Ill. Adm. Code 820.10-820.610 and Appendices; 210 ILCS 125/1-32; 20 ILCS 2310/2310-555 — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026
  2. 77 Ill. Adm. Code 820.320, 820.340(l), 820.350(b)-(c), 820.380 — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026
  3. 77 Ill. Adm. Code 820.10 ('Manager/Operator'), 820.300(a), 820.340(k)(1), (k)(8), 820.350(a); 210 ILCS 125/8, 125/12 — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Who regulates pools

  • The rule is the Swimming Facility Code, 77 Ill. Adm. Code 820. It is adopted under the Swimming Facility Act, 210 ILCS 125. [1]
  • It covers swimming, wading, plunge, therapy and wave pools, lazy rivers, spas, spray pools, water slides and bathing beaches, including pools at hotels, clubs, camps and schools. [1]
  • Private single-family pools for the owner and guests, and flotation tanks, are excluded. [1]
  • Lake Michigan beaches run by local governments are outside the Act. [4]
  • The Act was amended after the rule was last updated. Part 820 still cites the 2008 NEC and ANSI/APSP 16-2011. [1]
  1. 210 ILCS 125/4, 5, 5.1, 5.2, 6, 7, 11, 15.1, 27; 77 Ill. Adm. Code 820.100, 820.105, 820.600, 820.610 — Swimming Facility Act, 210 ILCS 125 (Illinois Compiled Statutes, ILGA) · checked October 21, 2026

Operator and technician certificates

  • Each swimming facility must designate a manager/operator who is responsible for running it in line with Part 820. [3]
  • Part 820 does not require the manager/operator to hold a pool operator certificate such as the CPO. [3]
  • Gas chlorinators may be repaired only by people trained to service them. [3]
  • Lifeguards must hold a recognized certification: American Red Cross, National Pool and Water Park, YMCA or equal. [5]
  • Guidance / not confirmed Suburban Cook County is reported to require a trained pool manager by county ordinance. This was not verified, so ask the local health department. [3]
  1. 77 Ill. Adm. Code 820.200(i), 820.300, 820.310, 820.315, 820.340(g), 820.360; Appendix B Table B — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Water chemistry ranges

Ranges as Part 820 states them. The same limits apply to spas, because the rule counts spas as pools.

WhatWhat the rule says
Free chlorine1.0 to 4.0 ppm (at least 2.0 ppm when the water is above 85 F) [2]
Bromine2.0 to 8.0 ppm as total bromine (at least 4.0 ppm above 85 F) [2]
pH7.2 to 7.6 [2]
Total alkalinity50 to 200 ppm as calcium carbonate [2]
Cyanuric acid100 ppm maximum. Above that, drain 50% and refill until below 50 ppm [2]
Combined chlorineAbove 0.5 ppm: superchlorinate to at least 10 times the combined level [2]
Copper / silver (ion generators)1.3 ppm / 0.05 ppm maximum [2]
Ambient ozoneBelow 0.1 ppm [2]
Indoor pool water temperature76 to 92 F, with the air warmer than the water [2]
ClarityThe whole basin must be visible from the deck [2]
  • Part 820 sets no separate spa chemistry ranges and no maximum spa water temperature. [2]
  • Polyphosphates may not exceed 10 ppm. [2]
  • For algae, superchlorinate to 10 ppm for several hours while the pool is closed. [6]
  1. 77 Ill. Adm. Code 820.330(a)-(k), 820.360(m); 210 ILCS 125/21 — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Required tests and how often

  • Test disinfectant and pH at least twice daily, in both the shallow and deep areas. [2]
  • Test combined chlorine and cyanuric acid at least weekly. Test ozone monthly. [2]
  • Required test kits: pH standards 6.8 to 8.0, DPD chlorine 0.5 to 3.0 ppm, bromine 1.0 to 5.0 ppm, and cyanuric acid readings up to 100 ppm. [2]
  • Pumps, filters and feeders run 24 hours a day and keep the design turnover. [7]
  1. 77 Ill. Adm. Code 820.210(a), (b), (d), (f), (h), (i); 820.140 — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Logs and record keeping

  • Record operating data daily for each pool or aquatic feature, on the IDPH report form or an equivalent. [3]
  • Keep the records at the facility for at least 3 years. [3]
  • Keep equipment manuals, pump curves, labeled valves and piping, and a valve operating procedure in the equipment room. [3]
  • Post the facility license. [3]
  • Report a drowning, or an injury or illness needing hospitalization, to IDPH within 24 hours. Send a written report within 7 days. [5]

When a pool must close

  • The manager/operator must close the facility at once if conditions are an immediate danger, the basin is not clearly visible, or disinfection or the pumps or filters are inoperable. [6]
  • Close for free chlorine below 0.5 ppm, bromine below 1.0 ppm, total chlorine above 5 ppm or total bromine above 10 ppm. [6]
  • Close for pH below 6.8 or above 8.0, or for a loose, damaged or missing suction outlet cover. [6]
  • Close for coliform at 10 per 100 ml in two consecutive samples, or for fecal coliform, E. coli, beta hemolytic Streptococcus or Pseudomonas in any sample. [6]
  • Outdoors, stop swimming when lightning is seen or thunder is heard. [6]
  • After a fecal or vomit incident: remove the matter, superchlorinate and stay closed at least 30 minutes. Facilities over 50,000 gallons may close only the affected area. [6]
  • IDPH can order immediate closure without a prior hearing in an emergency. [6]
  • Violations are Type A (fix immediately or within 10 days), Type B (plan of correction, up to $25 a day) or Type C (immediate closure possible, up to $100 a day). [4]

Drains and entrapment

  • Every outlet except skimmers needs a certified safety cover with openings no larger than 1/2 inch. It must not come off without tools. [8]
  • Suction outlets need a cover at least 18 by 23 inches, or at least two hydraulically balanced outlets 3 ft apart center to center. [8]
  • No suction outlet may sit on stair or seat treads. In-ground pools need a hydrostatic relief valve. [8]
  • Pools built before 2009 may skip the large-cover or dual-outlet rule if they have a safety vent pipe, a certified SVRS or gravity flow to a vented tank. [8]
  • The federal Virginia Graeme Baker Act also applies. [8]
  1. 77 Ill. Adm. Code 820.10, 820.20(b)(4)-(7), 820.145, 820.200(e), 820.210(e)(2), 820.210(f)(3), 820.330(i), 820.340(b), (k)(10); federal VGB Act (15 U.S.C. 8001-8008; 16 CFR 1450) — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Safety equipment

  • Lifeguards are required at wave pools and water slides, and at any pool where children under 16 may be inside the enclosure without a parent or responsible person 16 or older. [5]
  • Otherwise post the IDPH sign saying the pool is not protected by lifeguards. [5]
  • Without lifeguards carrying rescue devices, each 2,000 sq ft needs a Coast Guard ring buoy with throw rope, plus a 12-ft life hook. [5]
  • Also required: a first aid kit, an emergency phone within 300 ft, posted patron rules and the posted bather load. [5]
  • Children who are not toilet-trained must wear tight-fitting disposable swim diapers. [9]
  • Service animals trained to work in the water must be allowed unless they pose a direct threat or sanitary problem. Other animals are banned. [9]
  • No one may prohibit a life jacket for a person whose physician signs a statement that a condition requires it. [9]
  1. 210 ILCS 125/21.1, 125/32; 210 ILCS 130/2, 130/3; 77 Ill. Adm. Code 820.360(j), 820.400(e) — Swimming Facility Act, 210 ILCS 125 (Illinois Compiled Statutes, ILGA) · checked October 21, 2026

Fences and barriers

  • The pool area must be fully enclosed by a wall, fence or other barrier at least 4 feet high that gives no ready footing for climbing. The gap under it and openings in it may not exceed 4 inches. [10]
  • Every entrance needs a self-closing, self-latching door or gate with locking hardware. Keep gates closed and locked when the facility is closed. [10]
  • Wading pools and spray pools need their own barrier at least 3.5 feet high with self-closing, self-latching gates. [10]
  • No balcony may be within 10 ft horizontally of the water. [10]
  • No rule found Illinois has no statewide barrier, gate or alarm rule for private home pools. Cities and villages may require fences or covers by ordinance. [11]
  1. 77 Ill. Adm. Code 820.200(a), 820.230(d), 820.240(g), 820.340(f) — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026
  2. 65 ILCS 5/11-30-9; 55 ILCS 5/5-1066; HB2495 (104th General Assembly) — Illinois Municipal Code, 65 ILCS 5/11-30-9 (ILGA) · checked October 21, 2026

Signs and depth markers

  • Depth markers go at or above the water and on the deck edge, no more than 25 ft apart, with numerals at least 4 inches high. [12]
  • Mark shallow areas with no diving markers. [12]
  • IDPH publishes sign templates for pool rules, spa rules, no lifeguard and bather load on its program page. [5]
  1. 77 Ill. Adm. Code 820.200(b)-(q); Appendix A Illustrations A-D; Appendix B Table A — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026

Permits and inspections

  • An IDPH construction permit is required before building, installing or majorly altering a swimming facility. Construction permits always stay with IDPH. [4]
  • Plans come from an IDPH-prequalified Illinois architect or professional engineer. [4, 13]
  • Anyone who builds or majorly alters a public pool must be an IDPH-prequalified swimming facility contractor. Prequalification is free. [13]
  • The owner may not open until the facility is inspected and licensed. Licenses renew every year, cannot be transferred and must be posted. [4]
  • Sources disagree The Act says construction permits are valid for 2 years, but Part 820 still says one year. Confirm the expiration date on your IDPH permit. [14]
  • Scheduled change On 2027-01-01, conditional licenses may run up to 5 years to comply instead of 3. [4]
  1. 210 ILCS 125/30, 125/31; 77 Ill. Adm. Code 820.500-820.550, Appendix B Tables I-K — 77 Ill. Adm. Code 820, Illinois Swimming Facility Code (JCAR Administrative Code, entire Part) · checked October 21, 2026
  2. 210 ILCS 125/5 (as amended by P.A. 104-269) vs 77 Ill. Adm. Code 820.105(a)(1)(A) — Swimming Facility Act, 210 ILCS 125 (Illinois Compiled Statutes, ILGA) · checked October 21, 2026

Home pools: permits and inspections

  • Illinois has no statewide residential pool permit or construction code. Cities and counties adopt and enforce their own building codes. [15]
  • Illinois does not license general contractors or pool builders at the state level. Local governments may require permits, registration or licenses. [16]
  • The Home Repair and Remodeling Act covers building a pool at a home with 6 or fewer units. Jobs over $1,000 need a written contract with the total cost, signed by the customer. [16]
  1. 210 ILCS 125/3.01, 3.10; 65 ILCS 5/11-30-9; 55 ILCS 5/5-1066; 20 ILCS 3105/10.18; 815 ILCS 670/10, 15 — Capital Development Board, Building Codes and Regulations (statute texts on ilga.gov) · checked October 21, 2026
  2. 815 ILCS 513/10, 15, 20, 25, 35; 225 ILCS 320; 225 ILCS 335 — Home Repair and Remodeling Act, 815 ILCS 513 (ILGA) · checked October 21, 2026

Other things to know

  • Since 2026-01-01 a licensed facility may run a cold spa (water kept between 40 F and 60 F) with conditions: a warning sign, no children under 14, and a clock or timer in view. [17]
  • Scheduled change A cold spa also needs a staff member trained to recognize hypothermia and certified in first aid and CPR during business hours. IDPH has not yet adopted rules for it. [17]
  • Public pools need at least two accessible means of entry, at least one a pool lift or sloped entry. Pools with less than 300 linear feet of wall need only one. [18]
  • Pool wastewater may not go into a private septic system that receives domestic sewage. [19]
  1. 210 ILCS 125/3.25, 3.26, 21.2 (P.A. 104-269) — Swimming Facility Act, 210 ILCS 125 (Illinois Compiled Statutes, ILGA) · checked October 21, 2026
  2. 71 Ill. Adm. Code 400 (Appendix A, sections 242 and 1009); Environmental Barriers Act, 410 ILCS 25 — 71 Ill. Adm. Code 400, Illinois Accessibility Code (JCAR) · checked October 21, 2026
  3. 77 Ill. Adm. Code 820.120, 820.210(f)(1)(C), 820.210(h)(10); 77 Ill. Adm. Code 905.20(b), 905.160; 77 Ill. Adm. Code 890.1010(d); IEPA General NPDES Permit ILR40 Part I.B.2 — 77 Ill. Adm. Code 905, Private Sewage Disposal Code (JCAR); IEPA General NPDES Permit ILR40 (MS4) · checked October 21, 2026

Questions people ask

What is 77 IAC 820 in Illinois?

It is the Illinois Swimming Facility Code, the Illinois Department of Public Health rule for swimming facilities open to the public. It covers permits, licenses, design, water quality, operation, closures and lifeguards. [1]

What chlorine and pH levels does Illinois require?

Free chlorine 1.0 to 4.0 ppm (at least 2.0 ppm when the water is above 85 F) and pH 7.2 to 7.6. Total alkalinity is 50 to 200 ppm. [2]

How often must an Illinois pool be tested?

Disinfectant and pH at least twice daily. Combined chlorine and cyanuric acid at least weekly, and ozone monthly. [2]

Does Illinois require a CPO for a public pool?

No. Part 820 requires a designated manager/operator but does not require a pool operator certificate. Lifeguards must hold a recognized certification. [3]

How long must Illinois pool records be kept?

Daily operating records are kept at the facility for at least 3 years. [3]

Keep the records these rules ask for

  • Pool AI saves the readings and the chemicals added at every visit, with the date and the technician.
  • Commercial customers (condos, HOAs, hotels, apartments) can download their chemical log as a PDF or a spreadsheet from their own pool page.
  • Alerts when a reading leaves the range you set, and certificates for your team with renewal reminders.

Questions about a code or a reading? Blue, the free Pool AI assistant, answers pool questions in six languages.

Related pages

Rules change and local health departments can add their own. Confirm with your health department or building office before you rely on any rule here. Page updated November 24, 2026.