General information, not legal advice. Rules change and local health departments can add their own. Confirm with your health department or building office before you rely on any rule here.
Every fact below comes from the official rule text and links to it. Sources last checked October 22, 2026. 1 mg/L is the same as 1 ppm.
At a glance
- Wyoming's pool rule is run by the Department of Agriculture (WDA), Consumer Health Services, not the Department of Health. Local health departments may run their own programs. [1]
- Each general-use or limited-use public pool must have a Certified Pool Operator (CPO), Aquatic Facility Operator (AFO), NSPI Tech I or approved equivalent on staff or under contract. [2]
- Free chlorine must be 1.0 to 8.0 ppm in pools and 2.0 to 8.0 ppm in spas. pH must be 7.0 to 7.8. [3]
- Test sanitizer, pH, clarity and temperature before opening, every 4 hours while open and before closing. Keep daily logs 1 year. [4]
- Sources disagree An old WDA guidance sheet lists different numbers than the rule. Use the rule and confirm with WDA. [5]
- W.S. 35-28-101 to 35-28-111; WDA Rules, Public Swimming Pools (010.0008) ch. 1-7 (ch. 1 s. 2-4) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 1: General Provisions (Purpose, Variances, Definitions and Operator Requirements) (ref 010.0008.1.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 1 s. 7(a)(xxxi), 8(a)-(b), 9; W.S. 35-28-108(a) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 1: General Provisions (Purpose, Variances, Definitions and Operator Requirements) (ref 010.0008.1.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 5 s. 1(a), 2(f); ch. 4 s. 4(b) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 5: Water Quality, Test Kits, Record Keeping (ref 010.0008.5.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 5 s. 2-4; ch. 1 s. 10 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 5: Water Quality, Test Kits, Record Keeping (ref 010.0008.5.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 5 s. 1(a), ch. 6 s. 3(a); WDA 'Swimming Pool Basic List of Requirements' (rev. 8/04) — WDA Consumer Health Services, Swimming Pool Basic List of Requirements (Revised 8/04) · checked October 22, 2026
Who regulates pools
- The Public Pool and Spa Health and Safety Act (W.S. 35-28-101 to -111) has the WDA director run the pool program, with Department of Health help. [1]
- The rules are Wyoming Regulations for Swimming Pools, Spas and Similar Installations (chapters 1 to 7, effective 10/09/2003). [1]
- They cover general-use and limited-use public pools, spas, wading and plunge pools, flotation tanks and flumes. [1]
- Private single-family pools and tubs drained after each use are excluded. Flow-through pools are exempt from the act. [1]
- No proposed or emergency version of the rules was found on rules.wyo.gov. [1]
Operator and technician certificates
- The owner or operator of each general-use or limited-use public pool needs a current CPO, AFO, NSPI Tech I or other certification approved by the regulator, on staff or under contract. [2]
- A certified operator who leaves must be replaced within 90 days. Certification must be kept current. [2]
- The license holder must be, or name, a person in charge who knows pool operation and is available during all operating hours. [2]
- General-use public pools need one lifeguard per 40 bathers or fraction on deck. Lifeguards need current certification in lifeguarding, adult, child and infant CPR, and first aid. [6]
- Limited-use pools post a No Lifeguard on Duty sign instead of providing lifeguards. [6]
- WDA Rules 010.0008 ch. 6 s. 1, 2, 5 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 6: Lifeguards, Lifesaving Equipment; Ladders, Recessed Steps; Diving Boards; Slides, Flumes (ref 010.0008.6.10092003) · checked October 22, 2026
Water chemistry ranges
Required ranges from chapter 5 of the rule. Minimum and maximum are required; ideal values are targets.
| What | What the rule says |
|---|---|
| Free chlorine, pools | Minimum 1.0 ppm, ideal 2.0 to 3.0, maximum 8.0 [3] |
| Free chlorine, spas | Minimum 2.0 ppm, ideal 3.0 to 5.0, maximum 8.0 [3] |
| Combined chlorine | 0.5 ppm maximum [3] |
| Bromine, pools | Minimum 2.5 ppm, ideal 2.5 to 6.0, maximum 12.0 [3] |
| Bromine, spas | Minimum 4.5 ppm, ideal 5.5 to 7.5, maximum 12.0 [3] |
| pH | Minimum 7.0, ideal 7.4 to 7.6, maximum 7.8 [3] |
| Total alkalinity | 60 to 180 ppm (ideal depends on the sanitizer) [3] |
| Cyanuric acid | 100 ppm maximum (ideal 10 to 40); not used indoors [3] |
| Temperature | 98 F maximum in pools; 104 F in spas [3] |
| Calcium hardness | Minimum 150 ppm, ideal 200 to 400 [3] |
| ORP | At least 650 mV, supplemental only [3] |
| Clarity | Bottom and main drain grate clearly visible from the deepest part [3] |
- Sources disagree An old WDA sheet (revised 8/04) lists chlorine 1-10 ppm, pH 7.2-7.8 and a 16 ft reach pole. The rule says 1.0-8.0 ppm, pH 7.0-7.8 and a 12 ft pole. Follow the rule and confirm with WDA. [5]
- Gas chlorine equipment is not allowed on new public pools or spas. [7]
- WDA Rules 010.0008 ch. 4 s. 26-33 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 4: Sanitary Facilities and Controls (ref 010.0008.4.10092003) · checked October 22, 2026
Required tests and how often
- Test sanitizer level, pH, clarity and temperature once before opening, every 4 hours while open and once before closing. [4]
- Test total alkalinity and calcium hardness at least weekly. Test cyanuric acid monthly when it or stabilized chlorine is used. [4]
- Test kits must cover free and total chlorine, bromine or other sanitizer, cyanuric acid, alkalinity and hardness. Free chlorine kits must use DPD. OTO is not acceptable. [4]
- Spas are drained and refilled at least every 2 weeks. [4]
Logs and record keeping
When a pool must close
- If water is out of compliance for clarity, free chlorine, pH, temperature (spas and flotation tanks) or chemical or bacteriological quality, close to the public immediately. You may reopen once tests comply. [8]
- Clear the pool whenever clarity becomes a swimmer-safety issue in the operator's or lifeguard's judgment. [8]
- Stop operating and notify the regulator for an imminent hazard: fire, flood, extended loss of power or water, sewage backup, misuse of toxic materials or a gross insanitary condition. Reopening needs the regulator's approval. [8]
- Critical violations must be corrected during the inspection or within no more than 10 calendar days. Other violations get 90 days unless a written schedule is approved. [9]
- Knowing violations are misdemeanors: up to 6 months and/or $750. Imminent hazards allow summary suspension, with reinspection within 48 hours of notice that conditions are fixed. [9]
- WDA Rules 010.0008 ch. 1 s. 8(c); ch. 5 s. 2(b), 2(g); ch. 2 s. 10(a)(iii), 11, 12 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 2: Requirements for Plan Submission & Specifications; License Application & Issuance; Inspection (ref 010.0008.2.10092003) · checked October 22, 2026
- W.S. 35-28-105, 35-28-107, 35-28-109, 35-28-110; WDA Rules 010.0008 ch. 2 s. 13-29 — Wyoming Statutes Title 35, Chapter 28 - Public Pool and Spa Health and Safety (wyoleg.gov compiled title PDF) · checked October 22, 2026
Drains and entrapment
- Suction outlets other than skimmers need anti-vortex covers or grates tested to ASME/ANSI A112.19.8M R96. The federal Virginia Graeme Baker Act also applies. [10]
- At least two hydraulically balanced outlets per pump suction line. Outlets smaller than 12 in by 12 in are spaced 3 to 5 ft apart. [10]
- No valving may let one outlet be the pump's sole source. Grate velocity is 1 1/2 ft per second at most. [10]
- Spas need two equal outlets not valved apart, one anti-vortex drain at least 6 in in diameter, or a grate of 144 sq in or more. [10]
- WDA Rules 010.0008 ch. 4 s. 17-22; federal VGB Act 15 U.S.C. 8001 et seq. and 16 CFR 1450 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 4: Sanitary Facilities and Controls (ref 010.0008.4.10092003) · checked October 22, 2026
Safety equipment
- One lifesaving unit per 2,000 sq ft (or major fraction): a 20 in ring buoy or rescue tube with 1/4 in rope, plus a 12 ft reach pole with a shepherd's crook. [11]
- General-use pools also need a first aid station with a blanket and first aid kit. A telephone with posted emergency numbers is required. [11, 6]
- A lifeline with floats no more than 7 ft apart marks the slope break or the 5 ft 6 in depth. Ladders, steps or stairs go every 75 ft of perimeter, minimum two. [11]
- General-use and wave pools need one elevated lifeguard chair per 120 ft of perimeter, except pools 5 ft deep or less and wading pools. [6]
- Public pool heaters must meet ANSI Z21.56 (gas), UL 1261 (electric) or UL 559 (heat pumps), and electronic-ignition heaters must be wired in series with the circulation pump. [12]
- WDA Rules 010.0008 ch. 6 s. 3, 4, 6 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 6: Lifeguards, Lifesaving Equipment; Ladders, Recessed Steps; Diving Boards; Slides, Flumes (ref 010.0008.6.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 3 s. 7(e), 19-22; W.S. 35-9-106(d); DFPES Council rules 041.0002 ch. 1 s. 2(a)(v) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 3: General & Structural Design; Equipment Standards (ref 010.0008.3.10092003) · checked October 22, 2026
Fences and barriers
- All public pools must be enclosed by a fence, wall or building without private entrances to the pool area. [13]
- Enclosures must be at least 4 ft high, with no more than 4 in between the bottom and the ground or deck. [13]
- Gates must be self-closing, with a lockable, self-latching device on the inside at least 42 in above the ground. [13]
- Wading pools need their own barrier from the main pool. Equipment rooms are locked and chemicals stored out of users' reach. [13]
- WDA Rules 010.0008 ch. 3 s. 12(b)(iv), 29, 30(g); ch. 4 s. 8(a) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 3: General & Structural Design; Equipment Standards (ref 010.0008.3.10092003) · checked October 22, 2026
Signs and depth markers
- A sign at the enclosure entrance states the user rules, a 15-minute limit in the spa, and the emergency rescue number. Signs are at least 18 by 24 in with letters at least 1/2 in high. [14]
- Depth markings at least 4 in high, in contrasting color, go on the wall above the water and on the deck, no more than 25 ft apart. [14]
- Nonswimmers and children under 8 need a lifeguard present (at limited-use pools, a responsible person at least 18). [6]
- WDA Rules 010.0008 ch. 6 s. 14, 15; ch. 3 s. 10(b) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 6: Lifeguards, Lifesaving Equipment; Ladders, Recessed Steps; Diving Boards; Slides, Flumes (ref 010.0008.6.10092003) · checked October 22, 2026
Permits and inspections
- No public pool or spa may operate without a license from WDA or a local health department. Initial fee $100, renewal $50, and licenses expire June 30. [15]
- Plans must be approved before building or converting a pool. They come from a Wyoming-registered engineer or architect, or a licensed contractor. [15]
- The regulator does pre-operational inspections and inspects before issuing the license. Each separate circulation system needs a license. [15]
- Every licensed public pool or spa gets at least 1 inspection per year, more often based on risk. [9]
- W.S. 35-28-108; WDA Rules 010.0008 ch. 2 s. 1-8 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 2: Requirements for Plan Submission & Specifications; License Application & Issuance; Inspection (ref 010.0008.2.10092003) · checked October 22, 2026
Home pools: permits and inspections
- No rule found No Wyoming state rule governs residential pool permits or inspections. Building permits for houses and backyard pools come from cities and counties. [16]
- No rule found The state does not adopt the International Residential Code or the ISPSC. No statewide fence or barrier rule for private pools was found. Check the city or county. [17]
- A state electrical wiring permit is needed for new construction that needs utility power, except where a city or county has local electrical enforcement. [18]
- WDA Rules 010.0008 ch. 1 s. 4(b); DFPES Council rules 041.0002 ch. 1 s. 2(a); W.S. 35-9-106, 35-9-108(a), 35-9-120(e), 35-9-121 — Wyoming Administrative Rules, Fire Prevention & Electrical Safety, Dept. of, Council on Fire Prevention, Electrical Safety, Chapter 1: General Provisions (041.0002.1.06262024) · checked October 22, 2026
- WDA Rules 010.0008 ch. 1 s. 4(b); DFPES Council rules 041.0002 ch. 1 s. 2(a) — Wyoming Administrative Rules, Fire Prevention & Electrical Safety, Dept. of, Council on Fire Prevention, Electrical Safety, Chapter 1: General Provisions (041.0002.1.06262024) · checked October 22, 2026
- W.S. 35-9-120(a), (e), 35-9-121; DFPES Electrical Board rules 041.0001 ch. 2 (NEC definition); DFPES rules 041.0003 ch. 7 s. 1-2 — Wyoming State Fire Marshal / Dept. of Fire Prevention & Electrical Safety: Rules and Statutes (State of Wyoming Adopted Codes) · checked October 22, 2026
Other things to know
- Flow-through hot spring pools are exempt from the act. The rules apply only where the regulator decides. They must be drained and cleaned at least every 2 weeks. [19]
- Incoming water over 104 F is allowed only with signs reading Danger, water temperature exceeds 104 F, enter at your own risk, in letters at least 2 in high. [19]
- Existing gas chlorine systems need a separate vented room, a DANGER--CHLORINE sign, two full-face SCBAs and a leak detector with alarm. [7]
- Filter backwash and drained pool water go to a sanitary sewer through an air gap, or by other means the regulator approves. [20]
- No rule found No statewide pool, building or general contractor license was found. Pool wiring needs licensed electrical contractors, with exceptions for owners. [21, 22]
- The National Electrical Code is the statewide minimum. No Wyoming amendments to Article 680 were found. [18]
- W.S. 35-28-101(a)(xv), 35-28-111; WDA Rules 010.0008 ch. 1 s. 2(b), 7(a)(lxxiv); ch. 5 s. 2(f), 3(b), 5 — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 5: Water Quality, Test Kits, Record Keeping (ref 010.0008.5.10092003) · checked October 22, 2026
- WDA Rules 010.0008 ch. 4 s. 2, 3, 10(g); ch. 2 s. 6(c)(iv) — Wyoming Administrative Rules, Agriculture Dept. of, Public Swimming Pools (010.0008), Chapter 4: Sanitary Facilities and Controls (ref 010.0008.4.10092003) · checked October 22, 2026
- Wyoming Statutes Title 33 (chapter list); WDA Rules 010.0008 ch. 2 s. 6(a) — Wyoming Statutes Title 33 - Professions and Occupations (wyoleg.gov compiled title PDF) · checked October 22, 2026
- W.S. 35-9-102(a), 35-9-123, 35-9-125 to 35-9-127; Electrical Board rules 041.0001 ch. 5 — Wyoming Statutes Title 35, Chapter 9 - Department of Fire Prevention and Electrical Safety (wyoleg.gov compiled title PDF) · checked October 22, 2026
Questions people ask
Who regulates public pools in Wyoming?
The Department of Agriculture, Consumer Health Services, or a local health department running its own pool program. [1]
Does Wyoming require a certified pool operator?
Yes. Each general-use or limited-use public pool needs a CPO, AFO, NSPI Tech I or approved equivalent on staff or under contract. [2]
What chlorine and pH levels does Wyoming require?
Free chlorine 1.0 to 8.0 ppm in pools and 2.0 to 8.0 ppm in spas. pH 7.0 to 7.8. [3]
How often must Wyoming pool water be tested?
Before opening, every 4 hours while open and before closing. [4]
How long must Wyoming pool logs be kept?
Daily logs are kept 1 year. [4]
Keep the records these rules ask for
- Pool AI saves the readings and the chemicals added at every visit, with the date and the technician.
- Commercial customers (condos, HOAs, hotels, apartments) can download their chemical log as a PDF or a spreadsheet from their own pool page.
- Alerts when a reading leaves the range you set, and certificates for your team with renewal reminders.
Questions about a code or a reading? Blue, the free Pool AI assistant, answers pool questions in six languages.
Related pages
- Wyoming pool license guide
- Federal pool rules explained: VGB Act, CPSC and ADA
- Commercial pool service guide
- Pool chemical calculator
- LSI (water balance) calculator
- All free pool tools
- Pool codes in every state
Rules change and local health departments can add their own. Confirm with your health department or building office before you rely on any rule here. Page updated November 24, 2026.
