Pentair PowerMax commercial heater error codes

21 codes for PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750 and 1 more models: what each one means, what to check first, and when to call a pro.

Safety first

Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.

Jump to a code

CodeWhat it means
Flow SwitchInsufficient flow at the outlet of the heater
Low Water Cut OffInsufficient water level in the heat exchanger
Man Reset High LimitOutlet water went past the manual reset high limit setting
Auto Reset High LimitOutlet water exceeded the auto reset high limit setting
Pressure SwitchBlocked flue switch contacts are open
High Gas PressureHigh gas pressure switch tripped
Low Gas PressureLow gas pressure switch tripped
Field InterlockField interlock is open
Outlet SensorOutlet probe is not connected
Outlet Sensor DriftThe dual element outlet sensor readings do not agree
Inlet SensorInlet sensor damaged or not connected
Burner1 APS SwitchBurner 1 air proving switch contacts are open
Burner2 APS SwitchBurner 2 air proving switch contacts are open (1.25MM-2.0MM only)
Burner1 Parasitic FlameFlame sensed on burner 1 before ignition
Burner2 Parasitic FlameFlame sensed on burner 2 before ignition (1.0MM-2.0MM only)
Burner1 Max TrialsMaximum ignition attempts on burner 1 without sensing flame
Burner2 Max TrialsMaximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only)
Burner1 Max Flame LostMaximum allowed occurrences of burner 1 losing flame while running
Burner2 Max Flame LostMaximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only)
Burner1 Proven HSIBurner 1 proven HSI failed
Burner2 Proven HSIBurner 2 proven HSI failed (1.0MM-2.0MM only)

Flow Switch Insufficient flow at the outlet of the heater

What it means

Insufficient flow at the outlet of the heater.

Common causes

What to check, in order

  1. Replace the pump
  2. Replace the contactor
  3. Replace fuse F14 on the control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Low Water Cut Off Insufficient water level in the heat exchanger

What it means

Insufficient water level in the heat exchanger.

Common causes

What to check, in order

  1. Reset the LWCO with its reset button
  2. Verify the system is full and purged of air
  3. Check for loose jumpers if no LWCO is installed

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Man Reset High Limit Outlet water went past the manual reset high limit setting

What it means

Outlet water went past the manual reset high limit setting.

Common causes

What to check, in order

  1. Make sure the system is full of water and every bit of air has been purged.
  2. Confirm the heater is plumbed correctly into the heating system.
  3. Check pump operation
  4. Check the set point of the manual reset high limit.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Auto Reset High Limit Outlet water exceeded the auto reset high limit setting

What it means

Outlet water exceeded the auto reset high limit setting.

Common causes

What to check, in order

  1. Make sure the system is full of water and every bit of air has been purged.
  2. Confirm the heater is plumbed correctly into the heating system.
  3. Check pump operation
  4. Check the set point of the manual reset high limit.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Pressure Switch Blocked flue switch contacts are open

What it means

Blocked flue switch contacts are open.

Common causes

What to check, in order

  1. Check switch wiring: wires on the common and normally open terminals
  2. Check the reference hose and tubing for blockage
  3. Replace a faulty switch
  4. Verify the blower runs; replace if needed
  5. Replace fuse F12 (blower 1) or F13 (blower 2) on the control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, wiring, electrical parts (fuses, relays, transformers) or venting / flue is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

High Gas Pressure High gas pressure switch tripped

What it means

High gas pressure switch tripped.

Common causes

What to check, in order

  1. See Section 3 Gas Supply and Piping
  2. Verify supply and manifold gas pressures meet Section 8; correct if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Low Gas Pressure Low gas pressure switch tripped

What it means

Low gas pressure switch tripped.

Common causes

What to check, in order

  1. See Section 3 Gas Supply and Piping
  2. Verify supply and manifold gas pressures meet Section 8; correct if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Field Interlock Field interlock is open

What it means

Field interlock is open.

Common causes

What to check, in order

  1. If no field interlock device is fitted, look for a jumper that is loose or in the wrong place.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Ask Blue freeGive your techs Blue

Outlet Sensor Outlet probe is not connected

What it means

Outlet probe is not connected.

Common causes

What to check, in order

  1. Inspect the sensor and its wiring; repair or replace as needed.
  2. Outlet probe has 10K and 20K thermistors: one resistance should be double the other; replace if not
  3. Measure each element against the manufacturer's resistance chart (e.g. 10K: 12555 ohm at 68°F (20°C), 5279 at 104°F (40°C); 20K: 25099 / 10569)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Outlet Sensor Drift The dual element outlet sensor readings do not agree

What it means

The dual element outlet sensor readings do not agree.

Common causes

What to check, in order

  1. Inspect the sensor and its wiring; repair or replace as needed.
  2. Outlet probe has 10K and 20K thermistors: one resistance should be double the other; replace if not
  3. Measure each element against the manufacturer's resistance chart (e.g. 10K: 12555 ohm at 68°F (20°C), 5279 at 104°F (40°C); 20K: 25099 / 10569)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Inlet Sensor Inlet sensor damaged or not connected

What it means

Inlet sensor damaged or not connected.

Common causes

What to check, in order

  1. Inspect the sensor and its wiring; repair or replace as needed.
  2. Measure resistance against the manufacturer's chart (12555 ohm at 68°F/20°C ... 685 ohm at 212°F/100°C)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner1 APS Switch Burner 1 air proving switch contacts are open

What it means

Burner 1 air proving switch contacts are open.

Common causes

What to check, in order

  1. Check switch wiring: wires on the common and normally open terminals
  2. Check the reference hose and tubing for blockage
  3. Replace a faulty switch
  4. Verify the blower runs; replace if needed
  5. Replace fuse F12 on the control board (blower 1)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, control boards, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner2 APS Switch Burner 2 air proving switch contacts are open (1.25MM-2.0MM only)

What it means

Burner 2 air proving switch contacts are open (1.25MM-2.0MM only).

Common causes

What to check, in order

  1. Check switch wiring: wires on the common and normally open terminals
  2. Check the reference hose and tubing for blockage
  3. Replace a faulty switch
  4. Verify the blower runs; replace if needed
  5. Replace fuse F13 on the control board (blower 2)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, control boards, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner1 Parasitic Flame Flame sensed on burner 1 before ignition

What it means

Flame sensed on burner 1 before ignition.

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner2 Parasitic Flame Flame sensed on burner 2 before ignition (1.0MM-2.0MM only)

What it means

Flame sensed on burner 2 before ignition (1.0MM-2.0MM only).

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner1 Max Trials Maximum ignition attempts on burner 1 without sensing flame

What it means

Maximum ignition attempts on burner 1 without sensing flame.

Common causes

What to check, in order

  1. Verify supply and manifold gas pressures meet Section 8
  2. Verify intake and venting
  3. Inspect the burner
  4. During ignition verify 24VAC at the gas valve for that HSI (Section 7)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or measuring voltage is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner2 Max Trials Maximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only)

What it means

Maximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only).

Common causes

What to check, in order

  1. Verify supply and manifold gas pressures meet Section 8
  2. Verify intake and venting
  3. Inspect the burner
  4. During ignition verify 24VAC at the gas valve for that HSI (Section 7)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or measuring voltage is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner1 Max Flame Lost Maximum allowed occurrences of burner 1 losing flame while running

What it means

Maximum allowed occurrences of burner 1 losing flame while running.

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
  3. Verify supply and manifold gas pressures meet Section 8
  4. Verify intake and venting
  5. Check combustion
  6. Inspect the burner
  7. Inspect the heat exchanger

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner2 Max Flame Lost Maximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only)

What it means

Maximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only).

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
  3. Verify supply and manifold gas pressures meet Section 8
  4. Verify intake and venting
  5. Check combustion
  6. Inspect the burner
  7. Inspect the heat exchanger

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner1 Proven HSI Burner 1 proven HSI failed

What it means

Burner 1 proven HSI failed.

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
  3. During HSI warm-up verify 120VAC at the HSI (Section 7)
  4. Replace fuse F10 on the control board (HSI1)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, control boards or measuring voltage is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Burner2 Proven HSI Burner 2 proven HSI failed (1.0MM-2.0MM only)

What it means

Burner 2 proven HSI failed (1.0MM-2.0MM only).

Common causes

What to check, in order

  1. Inspect the HSI and its wiring for damage and continuity, and replace if needed.
  2. Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
  3. During HSI warm-up verify 120VAC at the HSI (Section 7)
  4. Replace fuse F11 on the control board (HSI2)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, control boards or measuring voltage is a job for a qualified technician.

Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Pentair code Flow Switch mean on PowerMax commercial heaters?

Insufficient flow at the outlet of the heater. First check: Replace the pump.

What does Pentair code Low Water Cut Off mean on PowerMax commercial heaters?

Insufficient water level in the heat exchanger. First check: Reset the LWCO with its reset button.

What does Pentair code Man Reset High Limit mean on PowerMax commercial heaters?

Outlet water went past the manual reset high limit setting. First check: Make sure the system is full of water and every bit of air has been purged.

What does Pentair code Auto Reset High Limit mean on PowerMax commercial heaters?

Outlet water exceeded the auto reset high limit setting. First check: Make sure the system is full of water and every bit of air has been purged.

What does Pentair code Pressure Switch mean on PowerMax commercial heaters?

Blocked flue switch contacts are open. First check: Check switch wiring: wires on the common and normally open terminals.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.