Safety first
Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.
Jump to a code
| Code | What it means |
|---|---|
| Flow Switch | Insufficient flow at the outlet of the heater |
| Low Water Cut Off | Insufficient water level in the heat exchanger |
| Man Reset High Limit | Outlet water went past the manual reset high limit setting |
| Auto Reset High Limit | Outlet water exceeded the auto reset high limit setting |
| Pressure Switch | Blocked flue switch contacts are open |
| High Gas Pressure | High gas pressure switch tripped |
| Low Gas Pressure | Low gas pressure switch tripped |
| Field Interlock | Field interlock is open |
| Outlet Sensor | Outlet probe is not connected |
| Outlet Sensor Drift | The dual element outlet sensor readings do not agree |
| Inlet Sensor | Inlet sensor damaged or not connected |
| Burner1 APS Switch | Burner 1 air proving switch contacts are open |
| Burner2 APS Switch | Burner 2 air proving switch contacts are open (1.25MM-2.0MM only) |
| Burner1 Parasitic Flame | Flame sensed on burner 1 before ignition |
| Burner2 Parasitic Flame | Flame sensed on burner 2 before ignition (1.0MM-2.0MM only) |
| Burner1 Max Trials | Maximum ignition attempts on burner 1 without sensing flame |
| Burner2 Max Trials | Maximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only) |
| Burner1 Max Flame Lost | Maximum allowed occurrences of burner 1 losing flame while running |
| Burner2 Max Flame Lost | Maximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only) |
| Burner1 Proven HSI | Burner 1 proven HSI failed |
| Burner2 Proven HSI | Burner 2 proven HSI failed (1.0MM-2.0MM only) |
Flow Switch Insufficient flow at the outlet of the heater
What it means
Insufficient flow at the outlet of the heater.
Common causes
- Faulty heater pump
- Faulty pump contactor
- Blown heater pump fuse
What to check, in order
- Replace the pump
- Replace the contactor
- Replace fuse F14 on the control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Low Water Cut Off Insufficient water level in the heat exchanger
What it means
Insufficient water level in the heat exchanger.
Common causes
- Low water level
- Air in system
- Loose jumper when no LWCO is installed
What to check, in order
- Reset the LWCO with its reset button
- Verify the system is full and purged of air
- Check for loose jumpers if no LWCO is installed
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Man Reset High Limit Outlet water went past the manual reset high limit setting
What it means
Outlet water went past the manual reset high limit setting.
Common causes
- Outlet water is over the manual reset high limit.
What to check, in order
- Make sure the system is full of water and every bit of air has been purged.
- Confirm the heater is plumbed correctly into the heating system.
- Check pump operation
- Check the set point of the manual reset high limit.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Auto Reset High Limit Outlet water exceeded the auto reset high limit setting
What it means
Outlet water exceeded the auto reset high limit setting.
Common causes
- Outlet water above the auto reset high limit
What to check, in order
- Make sure the system is full of water and every bit of air has been purged.
- Confirm the heater is plumbed correctly into the heating system.
- Check pump operation
- Check the set point of the manual reset high limit.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Pressure Switch Blocked flue switch contacts are open
What it means
Blocked flue switch contacts are open.
Common causes
- Blocked flue
- Wiring
- Blocked reference hose/tubing
- Faulty switch
- Blower not running
- Blown blower fuse
What to check, in order
- Check switch wiring: wires on the common and normally open terminals
- Check the reference hose and tubing for blockage
- Replace a faulty switch
- Verify the blower runs; replace if needed
- Replace fuse F12 (blower 1) or F13 (blower 2) on the control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, wiring, electrical parts (fuses, relays, transformers) or venting / flue is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
High Gas Pressure High gas pressure switch tripped
What it means
High gas pressure switch tripped.
Common causes
- Gas pressure too high
What to check, in order
- See Section 3 Gas Supply and Piping
- Verify supply and manifold gas pressures meet Section 8; correct if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Low Gas Pressure Low gas pressure switch tripped
What it means
Low gas pressure switch tripped.
Common causes
- Gas pressure too low
What to check, in order
- See Section 3 Gas Supply and Piping
- Verify supply and manifold gas pressures meet Section 8; correct if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Field Interlock Field interlock is open
What it means
Field interlock is open.
Common causes
- Field interlock open
- Loose or misplaced jumper when no interlock is installed
What to check, in order
- If no field interlock device is fitted, look for a jumper that is loose or in the wrong place.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Outlet Sensor Outlet probe is not connected
What it means
Outlet probe is not connected.
Common causes
- Outlet probe disconnected or failed
What to check, in order
- Inspect the sensor and its wiring; repair or replace as needed.
- Outlet probe has 10K and 20K thermistors: one resistance should be double the other; replace if not
- Measure each element against the manufacturer's resistance chart (e.g. 10K: 12555 ohm at 68°F (20°C), 5279 at 104°F (40°C); 20K: 25099 / 10569)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Outlet Sensor Drift The dual element outlet sensor readings do not agree
What it means
The dual element outlet sensor readings do not agree.
Common causes
- Outlet sensor elements disagree
What to check, in order
- Inspect the sensor and its wiring; repair or replace as needed.
- Outlet probe has 10K and 20K thermistors: one resistance should be double the other; replace if not
- Measure each element against the manufacturer's resistance chart (e.g. 10K: 12555 ohm at 68°F (20°C), 5279 at 104°F (40°C); 20K: 25099 / 10569)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Inlet Sensor Inlet sensor damaged or not connected
What it means
Inlet sensor damaged or not connected.
Common causes
- Inlet sensor damaged or disconnected
What to check, in order
- Inspect the sensor and its wiring; repair or replace as needed.
- Measure resistance against the manufacturer's chart (12555 ohm at 68°F/20°C ... 685 ohm at 212°F/100°C)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 54. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner1 APS Switch Burner 1 air proving switch contacts are open
What it means
Burner 1 air proving switch contacts are open.
Common causes
- Air proving switch open
What to check, in order
- Check switch wiring: wires on the common and normally open terminals
- Check the reference hose and tubing for blockage
- Replace a faulty switch
- Verify the blower runs; replace if needed
- Replace fuse F12 on the control board (blower 1)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, control boards, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner2 APS Switch Burner 2 air proving switch contacts are open (1.25MM-2.0MM only)
What it means
Burner 2 air proving switch contacts are open (1.25MM-2.0MM only).
Common causes
- Air proving switch open
What to check, in order
- Check switch wiring: wires on the common and normally open terminals
- Check the reference hose and tubing for blockage
- Replace a faulty switch
- Verify the blower runs; replace if needed
- Replace fuse F13 on the control board (blower 2)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, control boards, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner1 Parasitic Flame Flame sensed on burner 1 before ignition
What it means
Flame sensed on burner 1 before ignition.
Common causes
- Flame sensed before ignition
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner2 Parasitic Flame Flame sensed on burner 2 before ignition (1.0MM-2.0MM only)
What it means
Flame sensed on burner 2 before ignition (1.0MM-2.0MM only).
Common causes
- Flame sensed before ignition
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner1 Max Trials Maximum ignition attempts on burner 1 without sensing flame
What it means
Maximum ignition attempts on burner 1 without sensing flame.
Common causes
- Gas pressure
- Intake/venting
- Burner
- No 24VAC to the gas valve
What to check, in order
- Verify supply and manifold gas pressures meet Section 8
- Verify intake and venting
- Inspect the burner
- During ignition verify 24VAC at the gas valve for that HSI (Section 7)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or measuring voltage is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner2 Max Trials Maximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only)
What it means
Maximum ignition attempts on burner 2 without sensing flame (1.0MM-2.0MM only).
Common causes
- Gas pressure
- Intake/venting
- Burner
- No 24VAC to the gas valve
What to check, in order
- Verify supply and manifold gas pressures meet Section 8
- Verify intake and venting
- Inspect the burner
- During ignition verify 24VAC at the gas valve for that HSI (Section 7)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or measuring voltage is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner1 Max Flame Lost Maximum allowed occurrences of burner 1 losing flame while running
What it means
Maximum allowed occurrences of burner 1 losing flame while running.
Common causes
- Flame lost while running
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
- Verify supply and manifold gas pressures meet Section 8
- Verify intake and venting
- Check combustion
- Inspect the burner
- Inspect the heat exchanger
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner2 Max Flame Lost Maximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only)
What it means
Maximum allowed occurrences of burner 2 losing flame while running (1.0MM-2.0MM only).
Common causes
- Flame lost while running
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
- Verify supply and manifold gas pressures meet Section 8
- Verify intake and venting
- Check combustion
- Inspect the burner
- Inspect the heat exchanger
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, meter tests or wiring is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner1 Proven HSI Burner 1 proven HSI failed
What it means
Burner 1 proven HSI failed.
Common causes
- HSI or wiring failure
- Blown HSI fuse
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
- During HSI warm-up verify 120VAC at the HSI (Section 7)
- Replace fuse F10 on the control board (HSI1)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, control boards or measuring voltage is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Burner2 Proven HSI Burner 2 proven HSI failed (1.0MM-2.0MM only)
What it means
Burner 2 proven HSI failed (1.0MM-2.0MM only).
Common causes
- HSI or wiring failure
- Blown HSI fuse
What to check, in order
- Inspect the HSI and its wiring for damage and continuity, and replace if needed.
- Unplug and remove the igniter and measure resistance: 50-80 ohm, otherwise replace the HSI
- During HSI warm-up verify 120VAC at the HSI (Section 7)
- Replace fuse F11 on the control board (HSI2)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving burners, the igniter or ignition control, control boards or measuring voltage is a job for a qualified technician.
Applies to: PowerMax 500, PowerMax 750, PowerMax 1000, PowerMax 1250, PowerMax 1500, PowerMax 1750, PowerMax 2000
Source: the Pentair installation and operation instructions (P/N 472642 Rev. D 03/03/23), page 55. maker's manual (PDF) The same code is also in 1 other manual or revision.
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Pentair code Flow Switch mean on PowerMax commercial heaters?
Insufficient flow at the outlet of the heater. First check: Replace the pump.
What does Pentair code Low Water Cut Off mean on PowerMax commercial heaters?
Insufficient water level in the heat exchanger. First check: Reset the LWCO with its reset button.
What does Pentair code Man Reset High Limit mean on PowerMax commercial heaters?
Outlet water went past the manual reset high limit setting. First check: Make sure the system is full of water and every bit of air has been purged.
What does Pentair code Auto Reset High Limit mean on PowerMax commercial heaters?
Outlet water exceeded the auto reset high limit setting. First check: Make sure the system is full of water and every bit of air has been purged.
What does Pentair code Pressure Switch mean on PowerMax commercial heaters?
Blocked flue switch contacts are open. First check: Check switch wiring: wires on the common and normally open terminals.
Related
- Pentair MasterTemp heaters
- Pentair Max-E-Therm heaters (Sta-Rite)
- Pentair ETi 250 & ETi 400 heaters
- Pentair MiniMax 100 heaters
- All Pentair error codes
- All pool equipment error codes
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.