Safety first
Control panel: the high-voltage side of an automation or spa control is for a qualified technician or electrician. Turn the power off at the breaker before opening a door that exposes wiring. Never bypass a spa high-limit or a GFCI.
Jump to a code
| Code | What it means |
|---|---|
| Delayed | For information only: a compressor or other normal heating delay |
| Inlet Temp Sensor | Inlet temperature sensor error |
| Outlet Temp Sensor | Outlet temperature sensor error |
| Aux [#] Temp Sensor | Auxiliary temperature sensor error |
| Outdoor Temp Sensor | Outdoor temperature sensor error |
| Mode Fault | Sky-35 was unable to work out the mode from the sources it was given |
| MODbus [#] Fault | Appears as a warning on the affected heat source |
| Settings Fault | Settings failed to load |
| IP Network Fault | IP network fault |
| RTOS Fault | Software fault, or bad data coming from a connected device |
| WiFi/BT Module | WiFi/BT module error |
| No Serial Number | Serial number missing |
| No Model Set | No model is set, possibly a bad EEPROM |
Delayed For information only: a compressor or other normal heating delay
What it means
For information only: a compressor or other normal heating delay. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Inlet Temp Sensor Inlet temperature sensor error
What it means
Inlet temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Disconnected wires or defective sensor
What to check, in order
- Check the inlet temperature sensor
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Outlet Temp Sensor Outlet temperature sensor error
What it means
Outlet temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Disconnected wires or defective sensor
What to check, in order
- Check the outlet temperature sensor
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Aux [#] Temp Sensor Auxiliary temperature sensor error
What it means
Auxiliary temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Disconnected wires or defective sensor
What to check, in order
- Check the Aux [# / assigned-name] temperature sensor
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Outdoor Temp Sensor Outdoor temperature sensor error
What it means
Outdoor temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Disconnected wires or defective sensor
What to check, in order
- Check the outdoor temperature sensor
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Mode Fault Sky-35 was unable to work out the mode from the sources it was given
What it means
Sky-35 was unable to work out the mode from the sources it was given. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
MODbus [#] Fault Appears as a warning on the affected heat source
What it means
Appears as a warning on the affected heat source; MODbus faults do not go into the error log. The MODbus # 1/2/3 does not match the terminal #. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- MODbus wiring
What to check, in order
- Check the MODbus wiring connections
- Check A/B polarity
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
Settings Fault Settings failed to load
What it means
Settings failed to load. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Error loading settings
What to check, in order
- Power cycle
- Factory reset
- Software update
- Contact Tech Support
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
IP Network Fault IP network fault
What it means
IP network fault. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Ethernet connection / network switch / router
What to check, in order
- Check the ethernet connection and the presence of a network switch
- Power cycle the Sky-35 and/or network switch
- Reset the router (if used)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
RTOS Fault Software fault, or bad data coming from a connected device
What it means
Software fault, or bad data coming from a connected device. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Software fault
- Bad data from a connected device
What to check, in order
- Reset to the system defaults
- Update firmware
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 82. maker's manual (PDF)
WiFi/BT Module WiFi/BT module error
What it means
WiFi/BT module error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
What to check, in order
- Power cycle
- Reset to the system defaults
- Update firmware
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 83. maker's manual (PDF)
No Serial Number Serial number missing
What it means
Serial number missing. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
What to check, in order
- Contact Tech Support
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 83. maker's manual (PDF)
No Model Set No model is set, possibly a bad EEPROM
What it means
No model is set, possibly a bad EEPROM. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address.
Common causes
- Possible faulty EEPROM
What to check, in order
- Contact Tech Support
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: Raypak Sky-35 controller for multiple heat sources (touchscreen controller)
Source: the Raypak installation & operation manual (120-647E), page 83. maker's manual (PDF)
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Raypak code Inlet Temp Sensor mean on Sky-35 multiple heat source controller?
Inlet temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address. First check: Check the inlet temperature sensor.
What does Raypak code Outlet Temp Sensor mean on Sky-35 multiple heat source controller?
Outlet temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address. First check: Check the outlet temperature sensor.
What does Raypak code Aux [#] Temp Sensor mean on Sky-35 multiple heat source controller?
Auxiliary temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address. First check: Check the Aux [# / assigned-name] temperature sensor.
What does Raypak code Outdoor Temp Sensor mean on Sky-35 multiple heat source controller?
Outdoor temperature sensor error. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address. First check: Check the outdoor temperature sensor.
What does Raypak code MODbus [#] Fault mean on Sky-35 multiple heat source controller?
Appears as a warning on the affected heat source; MODbus faults do not go into the error log. The MODbus # 1/2/3 does not match the terminal #. The error clears by itself once its cause is fixed. To skip the lockout wait, choose Clear Errors > Yes in the menu. A connected heat source that passes on an error labels it with its model, as in Error 2: EBX 32, and a trailing number is the MODbus address. First check: Check the MODbus wiring connections.
Related
- All Raypak error codes
- All pool equipment error codes
- Pool water testing basics
- Free LSI calculator (water balance)
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.