Safety first
Pump: turn it off at the breaker before opening the drive or motor cover. Variable-speed drives can hold a dangerous charge for minutes after the power is off. Motor and drive wiring is for a qualified technician or electrician.
Jump to a code
| Code | What it means |
|---|---|
| SW Over current | Software over current |
| HW Over current | Hardware over current |
| DC Over voltage | DC capacitor over voltage |
| DC Under voltage | DC capacitor under voltage |
| PCB Temperature | Printed circuit board over temperature |
| IGBT Temperature | Inverter IGBT over temperature |
| Imbalance Current | Motor current imbalance |
| Prime Failure | Failure to Prime Pump |
| Startup Failure | Failure to Start Pump |
| Low Power | Low power |
| Loss of Phase | Loss of phase |
| Processor Failure | Processor failure |
| POWERING DOWN | Power down |
| Generic Fault | All other faults |
| Communication Error, Check Connections | The user interface could not establish communication with the controller within five seconds |
| Over temperature fault | Motor runs then stops because of an over-temperature fault |
| Over current fault | Motor runs then stops because of an over-current fault |
| ER --- | Communication error |
| Er ----- (power up) | Self-diagnostic check at power up found an error |
| OC | Overcurrent: the driver's output current is past the threshold (200% of rated current) |
| OV | Overvoltage: the main circuit's maximum DC voltage is past the threshold |
| UV | Under-voltage: main electric current is low |
| OH | Overheating (1.1kW): the motor heat sink is too hot |
| OC1 | Over current while adjusting speed |
| OC2 | Over current at steady speed |
| OV1 | Over voltage while decelerating |
| OC3 | Instantaneous over current |
| UV1 | Under voltage: main electric current has dropped too low |
| OC4 | Module over current |
| CE | Current transformer self inspection fault |
| OH1 | Overheat |
| FAULT LED SOLID | A fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over… |
| FAULT LED BLINKING | The user interface has a fault |
| FAULT LED | The unit has a fault error (quick start guide legend |
SW Over current Software over current
Display shows: SW Over current (red Fault LED on)
What it means
Software over current. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
HW Over current Hardware over current
Display shows: HW Over current (red Fault LED on)
What it means
Hardware over current. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
DC Over voltage DC capacitor over voltage
Display shows: DC Over voltage (red Fault LED on)
What it means
DC capacitor over voltage. Controller action: Control waiting for voltage to drop.
What to check, in order
- Wait: control waiting for voltage to drop
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
DC Under voltage DC capacitor under voltage
Display shows: DC Under voltage (red Fault LED on)
What it means
DC capacitor under voltage. Controller action: Control waiting for voltage to rise.
What to check, in order
- Wait: control waiting for voltage to rise
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
PCB Temperature Printed circuit board over temperature
Display shows: PCB Temperature (red Fault LED on)
What it means
Printed circuit board over temperature. Controller action: Control waiting for temperature to drop.
What to check, in order
- Wait: control waiting for temperature to drop
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
IGBT Temperature Inverter IGBT over temperature
Display shows: IGBT Temperature (red Fault LED on)
What it means
Inverter IGBT over temperature. Controller action: Control waiting for temperature to drop.
What to check, in order
- Wait: control waiting for temperature to drop
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Imbalance Current Motor current imbalance
Display shows: Imbalance Current (red Fault LED on)
What it means
Motor current imbalance. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Prime Failure Failure to Prime Pump
Display shows: Prime Failure (red Fault LED on)
What it means
Failure to Prime Pump. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Startup Failure Failure to Start Pump
Display shows: Startup Failure (red Fault LED on)
What it means
Failure to Start Pump. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Low Power Low power
Display shows: Low Power (red Fault LED on)
What it means
Low power. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Loss of Phase Loss of phase
Display shows: Loss of Phase (red Fault LED on)
What it means
Loss of phase. Controller action: Verify motor connected. Control will retry.
What to check, in order
- Verify the motor is connected
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Processor Failure Processor failure
Display shows: Processor Failure (red Fault LED on)
What it means
Processor failure. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
POWERING DOWN Power down
Display shows: POWERING DOWN (red Fault LED on)
What it means
Power down.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Generic Fault All other faults
Display shows: Generic Fault (red Fault LED on)
What it means
All other faults. Controller action: Control will retry.
What to check, in order
- Wait: the control will retry
- If the motor does not restart after the retry, contact your service professional
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Communication Error, Check Connections The user interface could not establish communication with the controller within five seconds
What it means
The user interface could not establish communication with the controller within five seconds.
Common causes
- No communication between user interface and controller
What to check, in order
- Check the connections
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)
Over temperature fault Motor runs then stops because of an over-temperature fault
Display shows: Over temperature fault (Motor Runs then Stops)
What it means
Motor runs then stops because of an over-temperature fault.
Common causes
- Dirt and debris on the back of the motor
What to check, in order
- Make sure the back of the motor has no dirt or debris.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP, PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 28. maker's manual (PDF) The same code is also in 1 other manual or revision.
Over current fault Motor runs then stops because of an over-current fault
Display shows: Over current fault (Motor Runs then Stops)
What it means
Motor runs then stops because of an over-current fault; the motor restarts automatically after one minute.
What to check, in order
- Wait: the motor will automatically restart after one minute
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS270VSP, PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 28. maker's manual (PDF) The same code is also in 1 other manual or revision.
ER --- Communication error
Display shows: "ER ---" (communication error)
What it means
Communication error.
Common causes
- Plug without good electrical contact
What to check, in order
- Make sure the plug has good electrical contact
- Reset the system: unplug from the power supply, wait at least 60 seconds, reconnect
- If the error keeps coming back, contact your technical service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.
Er ----- (power up) Self-diagnostic check at power up found an error
Display shows: "Er -----" at power up
What it means
Self-diagnostic check at power up found an error.
What to check, in order
- Have your installer or dealer fix the problem.
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 11. maker's manual (PDF) The same code is also in 1 other manual or revision.
OC Overcurrent: the driver's output current is past the threshold (200% of rated current)
Display shows: "Er: OC"
What it means
Overcurrent: the driver's output current is past the threshold (200% of rated current). When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.
Common causes
- Driver output failure
- Driver IPM module damaged
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.
OV Overvoltage: the main circuit's maximum DC voltage is past the threshold
Display shows: "Er: OV"
What it means
Overvoltage: the main circuit's maximum DC voltage is past the threshold. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.
Common causes
- Exceeding power supply maximum
- Power supply voltage exceeds the control settings
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.
UV Under-voltage: main electric current is low
Display shows: "Er: UV"
What it means
Under-voltage: main electric current is low. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver. Fault no. 51 'UV' (under voltage) is when low speed voltage gets detected right after the pump is connected to power.
Common causes
- The ambient temperature is too high.
- Supply voltage fluctuation is too large
- Fault no. 51: low speed voltage gets detected right after the pump is connected to power.
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.
OH Overheating (1.1kW): the motor heat sink is too hot
Display shows: "Er: OH"
What it means
Overheating (1.1kW): the motor heat sink is too hot. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.
Common causes
- Ambient temperature is too high
- Motor cooling fan does not work
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.
OC1 Over current while adjusting speed
Display shows: "Er: OC1" (fault no. 0)
What it means
Over current while adjusting speed.
Common causes
- Overload
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
OC2 Over current at steady speed
Display shows: "Er: OC2" (fault no. 1)
What it means
Over current at steady speed.
Common causes
- Output short circuit
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
OV1 Over voltage while decelerating
Display shows: "Er: OV1" (fault no. 2)
What it means
Over voltage while decelerating.
Common causes
- Abnormal deceleration
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
OC3 Instantaneous over current
Display shows: "Er: OC3" (fault no. 4)
What it means
Instantaneous over current.
Common causes
- Abnormal acceleration
- Overload
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
UV1 Under voltage: main electric current has dropped too low
Display shows: "Er: UV1" (fault no. 5)
What it means
Under voltage: main electric current has dropped too low.
Common causes
- Supply voltage fluctuates
- Low supply voltage during operation
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
OC4 Module over current
Display shows: "Er: OC4" (fault no. 6)
What it means
Module over current.
Common causes
- Module damaged
- Output short circuit
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
CE Current transformer self inspection fault
Display shows: "Er: CE" (fault no. 17)
What it means
Current transformer self inspection fault.
Common causes
- Strong interface.
- Current transformer fault
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
OH1 Overheat
Display shows: "Er: OH1" (fault no. 50)
What it means
Overheat.
Common causes
- High ambient temperature
- Blocked fan cover
- Motor fan malfunction
What to check, in order
- Press the START/STOP button to bring the controller back.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)
FAULT LED SOLID A fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over…
Display shows: Fault LED solidly on
What it means
A fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over current, or over temperature. The motor stops and stays off, and the fault status is checked every seven seconds. When the fault clears, the Fault LED goes out and the motor returns to its normal schedule by itself (only STOP works during the fault).
Common causes
- Over temperature
- Over current
- Over/under voltage
- Open phase of the motor
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241508 Rev 1), page 28. maker's manual (PDF)
FAULT LED BLINKING The user interface has a fault
What it means
The user interface has a fault. The motor stops for as long as the fault lasts, then starts again by itself when it clears.
Common causes
- User interface fault
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241508 Rev 1), page 28. maker's manual (PDF)
FAULT LED The unit has a fault error (quick start guide legend
Display shows: Fault LED lit
What it means
The unit has a fault error (quick start guide legend; see the PS165VSP owner's manual for solid/blinking meanings).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: PS165VSP
Source: the Raypak quick start guide (Catalog No. 6200.182), page 1. maker's manual (PDF)
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Raypak code Over temperature fault mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?
Motor runs then stops because of an over-temperature fault. First check: Make sure the back of the motor has no dirt or debris.
What does Raypak code Over current fault mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?
Motor runs then stops because of an over-current fault; the motor restarts automatically after one minute. First check: Wait: the motor will automatically restart after one minute.
What does Raypak code ER --- mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?
Communication error. First check: Make sure the plug has good electrical contact.
What does Raypak code Er ----- (power up) mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?
Self-diagnostic check at power up found an error. First check: Have your installer or dealer fix the problem.
What does Raypak code OC mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?
Overcurrent: the driver's output current is past the threshold (200% of rated current). When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver. First check: Press the START/STOP button to bring the controller back.
Related
- All Raypak error codes
- All pool equipment error codes
- Pool pump not priming or losing prime
- Pool filter pressure too high: what it means and what to do
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.