| Code | What it means |
|---|---|
| 01 | DC-link over-voltage |
| 02 | DC-link under-voltage |
| 03 | DC-link voltage is too low |
| 04 | IPM (Intelligent Power Module) over-current software protection tripped |
| 05 | IPM (Intelligent Power Module) over-current hardware protection tripped |
| 07 | AC input over-voltage |
| 08 | AC input under-voltage |
| 10 | Electronic thermal overload has tripped |
| 11 | Motor speed too high |
| 13 | IPM (Intelligent Power Module) temperature too high |
| 16 | Motor out of step |
| 17 | PFC output DC low voltage |
| 20 | Short circuit to ground |
| 21 | Motor phase short circuit |
| 22 | Output phase lack |
| 31 | Communication error with master |
| 41 | Current sampling sensor error |
| 42 | Inrush current preventing relay error |
| 43 | Voltage sensor error, AC voltage and DC voltage do not match |
| 51 | IPM (Intelligent Power Module) temperature sensor error |
| 60 | Motor rotor locked |
| 61 | DSP ROM error |
| 62 | DSP RAM error |
| 63 | DSP watchdog error |
| 66 | Internal communication error |
| 1 FLASH | Microprocessor fault: Microprocessor Start-Up |
| 2 FLASHES | Low voltage: voltage has to be above 208V AC |
| 3 FLASHES | Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C)) |
| 4 FLASHES | Thermal overload tripped: Motor is drawing too many amps |
| 5 FLASHES | High voltage: Voltage has exceeded 269V AC |
| 6 FLASHES | Shaft locked: the impeller or pump is jammed and the motor shaft stopped turning |
| 7 FLASHES | Self-test: One or more self-tests were not completed |
| 8 FLASHES | Motor Error: One or more phases are not connected |
01 DC-link over-voltage
Display shows: Red ERROR LED on, error code 01 on the LED display (Figure 11 example: 'E05')
What it means
DC-link over-voltage.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
02 DC-link under-voltage
Display shows: Red ERROR LED on, error code 02 on the LED display (Figure 11 example: 'E05')
What it means
DC-link under-voltage.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
03 DC-link voltage is too low
Display shows: Red ERROR LED on, error code 03 on the LED display (Figure 11 example: 'E05')
What it means
DC-link voltage is too low.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
04 IPM (Intelligent Power Module) over-current software protection tripped
Display shows: Red ERROR LED on, error code 04 on the LED display (Figure 11 example: 'E05')
What it means
IPM (Intelligent Power Module) over-current software protection tripped.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
05 IPM (Intelligent Power Module) over-current hardware protection tripped
Display shows: Red ERROR LED on, error code 05 on the LED display (Figure 11 example: 'E05')
What it means
IPM (Intelligent Power Module) over-current hardware protection tripped.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
07 AC input over-voltage
Display shows: Red ERROR LED on, error code 07 on the LED display (Figure 11 example: 'E05')
What it means
AC input over-voltage.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
08 AC input under-voltage
Display shows: Red ERROR LED on, error code 08 on the LED display (Figure 11 example: 'E05')
What it means
AC input under-voltage.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
10 Electronic thermal overload has tripped
Display shows: Red ERROR LED on, error code 10 on the LED display (Figure 11 example: 'E05')
What it means
Electronic thermal overload has tripped.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
11 Motor speed too high
Display shows: Red ERROR LED on, error code 11 on the LED display (Figure 11 example: 'E05')
What it means
Motor speed too high.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
13 IPM (Intelligent Power Module) temperature too high
Display shows: Red ERROR LED on, error code 13 on the LED display (Figure 11 example: 'E05')
What it means
IPM (Intelligent Power Module) temperature too high.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
16 Motor out of step
Display shows: Red ERROR LED on, error code 16 on the LED display (Figure 11 example: 'E05')
What it means
Motor out of step.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
17 PFC output DC low voltage
Display shows: Red ERROR LED on, error code 17 on the LED display (Figure 11 example: 'E05')
What it means
PFC output DC low voltage.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
20 Short circuit to ground
Display shows: Red ERROR LED on, error code 20 on the LED display (Figure 11 example: 'E05')
What it means
Short circuit to ground.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
21 Motor phase short circuit
Display shows: Red ERROR LED on, error code 21 on the LED display (Figure 11 example: 'E05')
What it means
Motor phase short circuit.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
22 Output phase lack
Display shows: Red ERROR LED on, error code 22 on the LED display (Figure 11 example: 'E05')
What it means
Output phase lack.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
31 Communication error with master
Display shows: Red ERROR LED on, error code 31 on the LED display (Figure 11 example: 'E05')
What it means
Communication error with master.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
41 Current sampling sensor error
Display shows: Red ERROR LED on, error code 41 on the LED display (Figure 11 example: 'E05')
What it means
Current sampling sensor error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
42 Inrush current preventing relay error
Display shows: Red ERROR LED on, error code 42 on the LED display (Figure 11 example: 'E05')
What it means
Inrush current preventing relay error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
43 Voltage sensor error, AC voltage and DC voltage do not match
Display shows: Red ERROR LED on, error code 43 on the LED display (Figure 11 example: 'E05')
What it means
Voltage sensor error, AC voltage and DC voltage do not match.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
51 IPM (Intelligent Power Module) temperature sensor error
Display shows: Red ERROR LED on, error code 51 on the LED display (Figure 11 example: 'E05')
What it means
IPM (Intelligent Power Module) temperature sensor error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
60 Motor rotor locked
Display shows: Red ERROR LED on, error code 60 on the LED display (Figure 11 example: 'E05')
What it means
Motor rotor locked.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
61 DSP ROM error
Display shows: Red ERROR LED on, error code 61 on the LED display (Figure 11 example: 'E05')
What it means
DSP ROM error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
62 DSP RAM error
Display shows: Red ERROR LED on, error code 62 on the LED display (Figure 11 example: 'E05')
What it means
DSP RAM error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
63 DSP watchdog error
Display shows: Red ERROR LED on, error code 63 on the LED display (Figure 11 example: 'E05')
What it means
DSP watchdog error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
66 Internal communication error
Display shows: Red ERROR LED on, error code 66 on the LED display (Figure 11 example: 'E05')
What it means
Internal communication error.
What to check, in order
- If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
- If the error code does not clear, contact your pool professional for service.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)
1 FLASH Microprocessor fault: Microprocessor Start-Up
Display shows: LED "Error" light: 1 flash - Microprocessor fault
What it means
Microprocessor fault: Microprocessor Start-Up. The flash sequence repeats until the condition is cleared.
Common causes
- Microprocessor Start-Up
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
2 FLASHES Low voltage: voltage has to be above 208V AC
Display shows: LED "Error" light: 2 flashes - Low voltage
What it means
Low voltage: voltage has to be above 208V AC. The control turns on by itself once voltage stays above 208V for more than six (6) seconds (the motor starts), and the condition clears itself. The flash pattern keeps repeating until the problem goes away.
Common causes
- Voltage has to be above 208V AC. The control turns on by itself once voltage stays above 208V for more than six (6) seconds (the motor starts).
What to check, in order
- During initial start-up (6-12 seconds delay) a momentary power drop can show the error light; the pump restarts itself once the voltage is above 208V for six seconds
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
3 FLASHES Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C))
Display shows: LED "Error" light: 3 flashes - Temperature too high / Temperature too low
What it means
Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C)); temperature too low < -20°C (4°F (-16°C)). The flash sequence repeats until the condition is cleared.
Common causes
- Temperature too high > 100°C (212°F (100°C)); temperature too low < -20°C (4°F (-16°C))
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
4 FLASHES Thermal overload tripped: Motor is drawing too many amps
Display shows: LED "Error" light: 4 flashes - Thermal overload tripped
What it means
Thermal overload tripped: Motor is drawing too many amps. The flash sequence repeats until the condition is cleared.
Common causes
- Motor is drawing too many amps
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
5 FLASHES High voltage: Voltage has exceeded 269V AC
Display shows: LED "Error" light: 5 flashes - High voltage
What it means
High voltage: Voltage has exceeded 269V AC. The flash sequence repeats until the condition is cleared.
Common causes
- Voltage has exceeded 269V AC
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
6 FLASHES Shaft locked: the impeller or pump is jammed and the motor shaft stopped turning
Display shows: LED "Error" light: 6 flashes - Shaft locked
What it means
Shaft locked: the impeller or pump is jammed and the motor shaft stopped turning. The flash pattern keeps repeating until the problem goes away.
Common causes
- The impeller or pump is jammed and the motor shaft stopped turning.
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
7 FLASHES Self-test: One or more self-tests were not completed
Display shows: LED "Error" light: 7 flashes - Self-test
What it means
Self-test: One or more self-tests were not completed. The flash sequence repeats until the condition is cleared.
Common causes
- One or more self-tests were not completed
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
8 FLASHES Motor Error: One or more phases are not connected
Display shows: LED "Error" light: 8 flashes - Motor Error
What it means
Motor Error: One or more phases are not connected. The flash sequence repeats until the condition is cleared.
Common causes
- One or more phases are not connected
What to check, in order
- Note the number of flashes and shut the pump down immediately
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Speck Badu code 1 FLASH mean on EcoM3 & 1.1 THP variable-speed pumps?
Microprocessor fault: Microprocessor Start-Up. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.
What does Speck Badu code 2 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?
Low voltage: voltage has to be above 208V AC. The control turns on by itself once voltage stays above 208V for more than six (6) seconds (the motor starts), and the condition clears itself. The flash pattern keeps repeating until the problem goes away. First check: During initial start-up (6-12 seconds delay) a momentary power drop can show the error light; the pump restarts itself once the voltage is above 208V for six seconds.
What does Speck Badu code 3 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?
Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C)); temperature too low < -20°C (4°F (-16°C)). The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.
What does Speck Badu code 4 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?
Thermal overload tripped: Motor is drawing too many amps. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.
What does Speck Badu code 5 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?
High voltage: Voltage has exceeded 269V AC. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.
Related
- All Speck Badu error codes
- All pool equipment error codes
- Pool pump not priming or losing prime
- Pool filter pressure too high: what it means and what to do
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.