Get Started

Pumps & drives

Speck Badu EcoM3 & 1.1 THP variable-speed pump error codes

33 codes for 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV), Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V): what each one means, what to check first, and when to call a pro.

Safety first

Pump: turn it off at the breaker before opening the drive or motor cover. Variable-speed drives can hold a dangerous charge for minutes after the power is off. Motor and drive wiring is for a qualified technician or electrician.

Jump to a code

CodeWhat it means
01DC-link over-voltage
02DC-link under-voltage
03DC-link voltage is too low
04IPM (Intelligent Power Module) over-current software protection tripped
05IPM (Intelligent Power Module) over-current hardware protection tripped
07AC input over-voltage
08AC input under-voltage
10Electronic thermal overload has tripped
11Motor speed too high
13IPM (Intelligent Power Module) temperature too high
16Motor out of step
17PFC output DC low voltage
20Short circuit to ground
21Motor phase short circuit
22Output phase lack
31Communication error with master
41Current sampling sensor error
42Inrush current preventing relay error
43Voltage sensor error, AC voltage and DC voltage do not match
51IPM (Intelligent Power Module) temperature sensor error
60Motor rotor locked
61DSP ROM error
62DSP RAM error
63DSP watchdog error
66Internal communication error
1 FLASHMicroprocessor fault: Microprocessor Start-Up
2 FLASHESLow voltage: voltage has to be above 208V AC
3 FLASHESTemperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C))
4 FLASHESThermal overload tripped: Motor is drawing too many amps
5 FLASHESHigh voltage: Voltage has exceeded 269V AC
6 FLASHESShaft locked: the impeller or pump is jammed and the motor shaft stopped turning
7 FLASHESSelf-test: One or more self-tests were not completed
8 FLASHESMotor Error: One or more phases are not connected

01 DC-link over-voltage

Display shows: Red ERROR LED on, error code 01 on the LED display (Figure 11 example: 'E05')

What it means

DC-link over-voltage.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

02 DC-link under-voltage

Display shows: Red ERROR LED on, error code 02 on the LED display (Figure 11 example: 'E05')

What it means

DC-link under-voltage.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

03 DC-link voltage is too low

Display shows: Red ERROR LED on, error code 03 on the LED display (Figure 11 example: 'E05')

What it means

DC-link voltage is too low.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

04 IPM (Intelligent Power Module) over-current software protection tripped

Display shows: Red ERROR LED on, error code 04 on the LED display (Figure 11 example: 'E05')

What it means

IPM (Intelligent Power Module) over-current software protection tripped.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

05 IPM (Intelligent Power Module) over-current hardware protection tripped

Display shows: Red ERROR LED on, error code 05 on the LED display (Figure 11 example: 'E05')

What it means

IPM (Intelligent Power Module) over-current hardware protection tripped.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

07 AC input over-voltage

Display shows: Red ERROR LED on, error code 07 on the LED display (Figure 11 example: 'E05')

What it means

AC input over-voltage.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

08 AC input under-voltage

Display shows: Red ERROR LED on, error code 08 on the LED display (Figure 11 example: 'E05')

What it means

AC input under-voltage.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

10 Electronic thermal overload has tripped

Display shows: Red ERROR LED on, error code 10 on the LED display (Figure 11 example: 'E05')

What it means

Electronic thermal overload has tripped.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

Ask Blue freeGive your techs Blue

11 Motor speed too high

Display shows: Red ERROR LED on, error code 11 on the LED display (Figure 11 example: 'E05')

What it means

Motor speed too high.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

13 IPM (Intelligent Power Module) temperature too high

Display shows: Red ERROR LED on, error code 13 on the LED display (Figure 11 example: 'E05')

What it means

IPM (Intelligent Power Module) temperature too high.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

16 Motor out of step

Display shows: Red ERROR LED on, error code 16 on the LED display (Figure 11 example: 'E05')

What it means

Motor out of step.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

17 PFC output DC low voltage

Display shows: Red ERROR LED on, error code 17 on the LED display (Figure 11 example: 'E05')

What it means

PFC output DC low voltage.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

20 Short circuit to ground

Display shows: Red ERROR LED on, error code 20 on the LED display (Figure 11 example: 'E05')

What it means

Short circuit to ground.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

21 Motor phase short circuit

Display shows: Red ERROR LED on, error code 21 on the LED display (Figure 11 example: 'E05')

What it means

Motor phase short circuit.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

22 Output phase lack

Display shows: Red ERROR LED on, error code 22 on the LED display (Figure 11 example: 'E05')

What it means

Output phase lack.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

31 Communication error with master

Display shows: Red ERROR LED on, error code 31 on the LED display (Figure 11 example: 'E05')

What it means

Communication error with master.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

41 Current sampling sensor error

Display shows: Red ERROR LED on, error code 41 on the LED display (Figure 11 example: 'E05')

What it means

Current sampling sensor error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

42 Inrush current preventing relay error

Display shows: Red ERROR LED on, error code 42 on the LED display (Figure 11 example: 'E05')

What it means

Inrush current preventing relay error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

43 Voltage sensor error, AC voltage and DC voltage do not match

Display shows: Red ERROR LED on, error code 43 on the LED display (Figure 11 example: 'E05')

What it means

Voltage sensor error, AC voltage and DC voltage do not match.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

51 IPM (Intelligent Power Module) temperature sensor error

Display shows: Red ERROR LED on, error code 51 on the LED display (Figure 11 example: 'E05')

What it means

IPM (Intelligent Power Module) temperature sensor error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

60 Motor rotor locked

Display shows: Red ERROR LED on, error code 60 on the LED display (Figure 11 example: 'E05')

What it means

Motor rotor locked.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

61 DSP ROM error

Display shows: Red ERROR LED on, error code 61 on the LED display (Figure 11 example: 'E05')

What it means

DSP ROM error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

62 DSP RAM error

Display shows: Red ERROR LED on, error code 62 on the LED display (Figure 11 example: 'E05')

What it means

DSP RAM error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

63 DSP watchdog error

Display shows: Red ERROR LED on, error code 63 on the LED display (Figure 11 example: 'E05')

What it means

DSP watchdog error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

66 Internal communication error

Display shows: Red ERROR LED on, error code 66 on the LED display (Figure 11 example: 'E05')

What it means

Internal communication error.

What to check, in order

  1. If the error code will not clear, reboot the controller: turn power to the pump OFF, wait 10 minutes, turn it back on
  2. If the error code does not clear, contact your pool professional for service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 1.1 THP Dual Voltage Series Variable Speed Pool Pump Motor (E71-II VHV)
Source: the Speck Badu installation, operation and service manual (Version 2.0 01/2022), page 17. maker's manual (PDF)

1 FLASH Microprocessor fault: Microprocessor Start-Up

Display shows: LED "Error" light: 1 flash - Microprocessor fault

What it means

Microprocessor fault: Microprocessor Start-Up. The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

2 FLASHES Low voltage: voltage has to be above 208V AC

Display shows: LED "Error" light: 2 flashes - Low voltage

What it means

Low voltage: voltage has to be above 208V AC. The control turns on by itself once voltage stays above 208V for more than six (6) seconds (the motor starts), and the condition clears itself. The flash pattern keeps repeating until the problem goes away.

Common causes

What to check, in order

  1. During initial start-up (6-12 seconds delay) a momentary power drop can show the error light; the pump restarts itself once the voltage is above 208V for six seconds

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

3 FLASHES Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C))

Display shows: LED "Error" light: 3 flashes - Temperature too high / Temperature too low

What it means

Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C)); temperature too low < -20°C (4°F (-16°C)). The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

4 FLASHES Thermal overload tripped: Motor is drawing too many amps

Display shows: LED "Error" light: 4 flashes - Thermal overload tripped

What it means

Thermal overload tripped: Motor is drawing too many amps. The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

5 FLASHES High voltage: Voltage has exceeded 269V AC

Display shows: LED "Error" light: 5 flashes - High voltage

What it means

High voltage: Voltage has exceeded 269V AC. The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

6 FLASHES Shaft locked: the impeller or pump is jammed and the motor shaft stopped turning

Display shows: LED "Error" light: 6 flashes - Shaft locked

What it means

Shaft locked: the impeller or pump is jammed and the motor shaft stopped turning. The flash pattern keeps repeating until the problem goes away.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

7 FLASHES Self-test: One or more self-tests were not completed

Display shows: LED "Error" light: 7 flashes - Self-test

What it means

Self-test: One or more self-tests were not completed. The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

8 FLASHES Motor Error: One or more phases are not connected

Display shows: LED "Error" light: 8 flashes - Motor Error

What it means

Motor Error: One or more phases are not connected. The flash sequence repeats until the condition is cleared.

Common causes

What to check, in order

  1. Note the number of flashes and shut the pump down immediately

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: Badu EcoM3, Badu EcoM3 - Variable Speed (EcoM3V)
Source: the Speck Badu installation, operating and service manual, page 15. maker's manual (PDF) The same code is also in 1 other manual or revision.

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Speck Badu code 1 FLASH mean on EcoM3 & 1.1 THP variable-speed pumps?

Microprocessor fault: Microprocessor Start-Up. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.

What does Speck Badu code 2 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?

Low voltage: voltage has to be above 208V AC. The control turns on by itself once voltage stays above 208V for more than six (6) seconds (the motor starts), and the condition clears itself. The flash pattern keeps repeating until the problem goes away. First check: During initial start-up (6-12 seconds delay) a momentary power drop can show the error light; the pump restarts itself once the voltage is above 208V for six seconds.

What does Speck Badu code 3 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?

Temperature too high / Temperature too low: Temperature too high > 100°C (212°F (100°C)); temperature too low < -20°C (4°F (-16°C)). The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.

What does Speck Badu code 4 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?

Thermal overload tripped: Motor is drawing too many amps. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.

What does Speck Badu code 5 FLASHES mean on EcoM3 & 1.1 THP variable-speed pumps?

High voltage: Voltage has exceeded 269V AC. The flash sequence repeats until the condition is cleared. First check: Note the number of flashes and shut the pump down immediately.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.