Jandy CXi commercial heater error codes

27 codes for CXi 500, CXi 650, CXi 750: what each one means, what to check first, and when to call a pro.

Safety first

Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.

Jump to a code

CodeWhat it means
Gas Pressure SWOptional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset…
Flow Switch/ LWCOThe flow switch or optional low water cutoff is not making
Flame SequenceFlame signal seen while the gas valve is de-energized
Anti-cyclingCall for heat received too soon after the previous one ended
No Flame IgnBurner flame not proven on ignition
HSI Current LowHot surface igniter draw below the 2.6 A minimum
Flame CKT ErrorMain control board internal fault
No Flame RunningFlame signal lost while running
Auto Reset High LimitOutlet water temperature exceeded the automatic reset high limit setting
Manual Reset High LimitOutlet water temperature exceeded the adjustable high limit setting
Inlet LowInlet water failed to pass 130° within 15 minutes after ignition
Sensor OpenInlet, outlet, system supply, system return or outdoor sensor disconnected
Sensor ShortedInlet, outlet, system supply, system return or outdoor sensor shorted
Louver ProvingOptional remote proving switch is not making
APS OpenThe combustion air blower started, but the air pressure switch had not closed after 1 minute
APS ClosedAir pressure switch closed before the combustion air blower started
Wrong ID PlugThe control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5)
Temp O/ShootTwo conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above…
Rem Ctrl FltExternal control is cycling too often
Parameters ProgrParameters were loaded from a laptop, so the main control board needs a reset
Service BlkIn Service Mode the outlet temperature exceeded 185°F (85°C)
Low Voltage120VAC input to the main control board dropped below 100VAC
Watch Dog ErrorMain control board internal fault
Write EEPromMain control board internal fault
Program EEPromMain control board internal fault
CRC ParametersMain control board internal fault
No Error StoredMain control board internal fault

Gas Pressure SW Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset…

What it means

Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset low gas switch open). Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Reset the pressure switches
  2. Measure supply gas pressure to find the cause
  3. Correct supply gas pressure if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)

Flow Switch/ LWCO The flow switch or optional low water cutoff is not making

What it means

The flow switch or optional low water cutoff is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected.

Common causes

What to check, in order

  1. On a call for heat, see whether the pump runs.
  2. Look for closed valves or blockages in the piping.
  3. Make sure the system is full of water and every bit of air has been purged.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)

Flame Sequence Flame signal seen while the gas valve is de-energized

What it means

Flame signal seen while the gas valve is de-energized. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Check supply voltage polarity
  2. Check that the gas valve is closed
  3. Check external wiring for voltage feedback
  4. Check internal wiring for bad connections
  5. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)

Anti-cycling Call for heat received too soon after the previous one ended

What it means

Call for heat received too soon after the previous one ended.

Common causes

What to check, in order

  1. None needed: the board releases the call after a set time, or if the outlet temperature drops too quickly

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)

No Flame Ign Burner flame not proven on ignition

What it means

Burner flame not proven on ignition. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Examine the igniter and its wiring; clean or replace them.
  2. Check unit grounding
  3. Check incoming gas pressure
  4. Check the gas valve-to-combustion air chamber tube
  5. Check vent/air intake pipes for correct installation and obstructions
  6. Examine the burners; clean or replace them.
  7. Test the manifold gas pressure and the combustion settings.
  8. Check 24VAC to the gas valve during ignition; if missing check wiring to the main control board
  9. Replace wiring or the main control board as needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)

HSI Current Low Hot surface igniter draw below the 2.6 A minimum

What it means

Hot surface igniter draw below the 2.6 A minimum. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Measure igniter amps during trial for ignition: below 2.6 A replace the igniter
  2. Above 2.6 A replace the control module

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)

Flame CKT Error Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)

No Flame Running Flame signal lost while running

What it means

Flame signal lost while running. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Inspect igniter and wiring; clean or replace
  2. Check unit grounding
  3. Check incoming gas pressure
  4. Check the gas valve-to-combustion air chamber tube
  5. Check vent/air intake pipes
  6. Test the manifold gas pressure and combustion.
  7. Inspect, clean or replace burners
  8. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 31. maker's manual (PDF)

Ask Blue freeGive your techs Blue

Auto Reset High Limit Outlet water temperature exceeded the automatic reset high limit setting

What it means

Outlet water temperature exceeded the automatic reset high limit setting.

Common causes

What to check, in order

  1. Make sure the system is full of water and every bit of air has been purged.
  2. Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
  3. On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
  4. If 120VAC is present and the pump does not run, replace the pump
  5. With a variable speed pump, make sure system flow is not less than heater flow
  6. Check the board temperature setting
  7. Compare the water sensor resistance with the specified values; replace the sensor if needed.
  8. Replace the outlet sensor

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 31. maker's manual (PDF)

Manual Reset High Limit Outlet water temperature exceeded the adjustable high limit setting

What it means

Outlet water temperature exceeded the adjustable high limit setting. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Verify the adjustable high limit setting
  2. Make sure the system is full of water and every bit of air has been purged.
  3. Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
  4. On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
  5. If 120VAC is present and the pump does not run, replace the pump
  6. With a variable speed pump, make sure system flow is not less than heater flow
  7. Check the board temperature setting
  8. Compare the water sensor's resistance with the specified values and replace it if needed.
  9. Replace the outlet sensor or high limit

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)

Inlet Low Inlet water failed to pass 130° within 15 minutes after ignition

What it means

Inlet water failed to pass 130° within 15 minutes after ignition.

Common causes

What to check, in order

  1. Inspect the wiring that runs from the low voltage connection board to the 3-way valve.
  2. After the heater fires, look for 24VAC across Close and COM at the 3-way valve. If 24VAC is there but the valve stays still, replace it.
  3. Replace the inlet sensor
  4. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)

Sensor Open Inlet, outlet, system supply, system return or outdoor sensor disconnected

What it means

Inlet, outlet, system supply, system return or outdoor sensor disconnected. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Check sensors and wiring; repair or replace
  2. Compare the sensor resistance with the specified values.
  3. Replace the sensor if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)

Sensor Shorted Inlet, outlet, system supply, system return or outdoor sensor shorted

What it means

Inlet, outlet, system supply, system return or outdoor sensor shorted. Manual reset needed after correction (RESET on the CXi display).

Common causes

What to check, in order

  1. Check sensors and wiring; repair or replace
  2. Compare the sensor resistance with the specified values.
  3. Replace the sensor if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)

Louver Proving Optional remote proving switch is not making

What it means

Optional remote proving switch is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected.

Common causes

What to check, in order

  1. Check remote devices
  2. Check for a loose or misplaced jumper if no proving switch is installed

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)

APS Open The combustion air blower started, but the air pressure switch had not closed after 1 minute

What it means

The combustion air blower started, but the air pressure switch had not closed after 1 minute. The lockout clears itself after 5 minutes, or press RESET after the fix.

Common causes

What to check, in order

  1. Clean or replace the air filter
  2. Vent/air intake lengths must not exceed the maximum
  3. Clear blockage in vent/air inlet pipe or terminations
  4. Check the combustion air blower; replace if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)

APS Closed Air pressure switch closed before the combustion air blower started

What it means

Air pressure switch closed before the combustion air blower started. Lockout resets automatically after 5 minutes, or press RESET once corrected.

Common causes

What to check, in order

  1. Check for a jumper on the air pressure switch
  2. Look for an unusually strong negative draft in the vent stack.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)

Wrong ID Plug The control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5)

What it means

The control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5).

Common causes

What to check, in order

  1. Check the ID plug on connector X5
  2. Check ID plug wiring and connectors
  3. Confirm the number on the panel label equals parameter I5; if it does not, replace the control module.
  4. When replacing a module, confirm I5 matches the label, then press ENTER; otherwise replace the module

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)

Temp O/Shoot Two conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above…

What it means

Two conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above the maximum outlet temperature. Lockout resets automatically after 5 minutes, or press RESET once corrected.

Common causes

What to check, in order

  1. Make sure the system is full of water and every bit of air has been purged.
  2. Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
  3. On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
  4. If 120VAC is present and the pump does not run, replace the pump
  5. Outlet over maximum: replace the main control board if the above check out

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)

Rem Ctrl Flt External control is cycling too often

What it means

External control is cycling too often.

Common causes

What to check, in order

  1. Check the external control set point
  2. Check the wires that run from the outside controller to the unit.
  3. Replace the control

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)

Parameters Progr Parameters were loaded from a laptop, so the main control board needs a reset

What it means

Parameters were loaded from a laptop, so the main control board needs a reset. After the correction, reset it by hand (RESET on the CXi display).

Common causes

What to check, in order

  1. Press ENTER/RESET on the CXi display

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)

Service Blk In Service Mode the outlet temperature exceeded 185°F (85°C)

What it means

In Service Mode the outlet temperature exceeded 185°F (85°C).

Common causes

What to check, in order

  1. Create a heating load to remove heat
  2. Make sure the system is full of water and every bit of air has been purged.
  3. Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
  4. On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
  5. If 120VAC is present and the pump does not run, replace the pump

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

Low Voltage 120VAC input to the main control board dropped below 100VAC

What it means

120VAC input to the main control board dropped below 100VAC.

Common causes

What to check, in order

  1. Check 120VAC supply to the transformer
  2. Check connections at the low voltage terminal strip
  3. Check wire size/length to remote devices
  4. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

Watch Dog Error Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Cycle main power
  2. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

Write EEProm Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Cycle main power
  2. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

Program EEProm Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Cycle main power
  2. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

CRC Parameters Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Cycle main power
  2. Replace the main control board
  3. Restore default parameters with the PC program

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

No Error Stored Main control board internal fault

What it means

Main control board internal fault.

Common causes

What to check, in order

  1. Press RESET
  2. Cycle main power
  3. Replace the main control board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Jandy code Gas Pressure SW mean on CXi commercial heaters?

Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset low gas switch open). Manual reset needed after correction (RESET on the CXi display). First check: Reset the pressure switches.

What does Jandy code Flow Switch/ LWCO mean on CXi commercial heaters?

The flow switch or optional low water cutoff is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected. First check: On a call for heat, see whether the pump runs.

What does Jandy code Flame Sequence mean on CXi commercial heaters?

Flame signal seen while the gas valve is de-energized. Manual reset needed after correction (RESET on the CXi display). First check: Check supply voltage polarity.

What does Jandy code Anti-cycling mean on CXi commercial heaters?

Call for heat received too soon after the previous one ended. First check: None needed: the board releases the call after a set time, or if the outlet temperature drops too quickly.

What does Jandy code No Flame Ign mean on CXi commercial heaters?

Burner flame not proven on ignition. Manual reset needed after correction (RESET on the CXi display). First check: Examine the igniter and its wiring; clean or replace them.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.