Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.
Jump to a code
| Code | What it means |
|---|---|
| FAULT- PUMP | Pump is not running while the control is in Maintain Temp mode (normal) |
| FAULT- HIGH LIMIT | Water temperature in the heater exceeds the internal limit, or limit switch fault |
| FAULT- FUSELINK/FIELD | Roll-out (fusible link) fault or vent temperature limit fault |
| FAULT- CHECK IGN CONTROL | Ignition control fault (see the ignition control LED codes) |
| FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSOR | Water temperature sensor shorted or open |
| LED on continuously | Ignition control fault |
| LED single flash | Air flow fault |
| LED double flash | Flame is present with no call for heat |
| LED triple flash | Ignition lockout: the heater cycled three times and locked out after the third try |
| NO FLOW | No water flow detected |
FAULT- PUMP Pump is not running while the control is in Maintain Temp mode (normal)
Display shows: Display shows FAULT- PUMP
What it means
Pump is not running while the control is in Maintain Temp mode (normal).
Common causes
- Pump is not running
What to check, in order
- No service required; normal in Maintain Temp mode
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
FAULT- HIGH LIMIT Water temperature in the heater exceeds the internal limit, or limit switch fault
What it means
Water temperature in the heater exceeds the internal limit, or limit switch fault.
Common causes
- Water temperature inside the heater is over the internal limit.
- Limit switch fault
What to check, in order
- Check the high limit switches, run a temperature rise test, and find and fix what is causing the overheating. Refer to qualified service personnel.
- Replace the switches, or tighten any loose connections. Refer to qualified service personnel.
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
FAULT- FUSELINK/FIELD Roll-out (fusible link) fault or vent temperature limit fault
What it means
Roll-out (fusible link) fault or vent temperature limit fault.
Common causes
- Roll-out (fusible link) switch fault (152°C, no marking)
- Vent temperature limit fault (240°C, marked with red paint)
What to check, in order
- Replace the roll-out (fusible link) switch, or tighten any loose connections. Refer to qualified service personnel.
- Replace the vent temperature limit switch, or tighten any loose connections. Refer to qualified service personnel.
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
FAULT- CHECK IGN CONTROL Ignition control fault (see the ignition control LED codes)
What it means
Ignition control fault (see the ignition control LED codes).
Common causes
- Broken, split, pinched or disconnected fan/switch tubing
- Fan not operating
- Fan running slow or premature fan failure
- Air flow restricted at intake or discharge
- Oscillating pump pressure
- Low gas supply pressure
- No flame at burners
What to check, in order
- Check tubing and replace if needed
- Correct the fault or replace the fan (qualified service personnel)
- Verify proper wiring for 120VAC or 240VAC (qualified service personnel)
- Check clearances, room ventilation and flue discharge (qualified service personnel)
- Clean the filter or repair the cause of pump oscillation
- Correct supply pipe size or pipe blockage
- Qualified service personnel should fix loose wiring or faults in the ignition control, gas valve, flame sensor or igniter.
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSOR Water temperature sensor shorted or open
Display shows: FAULT- SHORTED H2O SENSOR or FAULT- OPEN WATER SENSOR
What it means
Water temperature sensor shorted or open.
Common causes
- Faulty wiring or connection
- Failed sensor
What to check, in order
- Check sensor wiring and its connection to the Power Interface Board
- Replace the temperature sensor; refer to qualified service personnel
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
LED on continuously Ignition control fault
Display shows: Ignition control LED on continuously
What it means
Ignition control fault.
Common causes
- Ignition control fault
What to check, in order
- Refer to qualified service personnel
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 40. maker's manual (PDF) The same code is also in 1 other manual or revision.
LED single flash Air flow fault
Display shows: Ignition control LED single flash
What it means
Air flow fault.
Common causes
- Air flow fault
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 40. maker's manual (PDF) The same code is also in 1 other manual or revision.
LED double flash Flame is present with no call for heat
Display shows: Ignition control LED double flash
What it means
Flame is present with no call for heat.
Common causes
- Flame present with no call for heat
What to check, in order
- Refer to qualified service personnel
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 40. maker's manual (PDF) The same code is also in 1 other manual or revision.
LED triple flash Ignition lockout: the heater cycled three times and locked out after the third try
Display shows: Ignition control LED triple flash
What it means
Ignition lockout: the heater cycled three times and locked out after the third try.
Common causes
- Three failed ignition cycles
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 40. maker's manual (PDF) The same code is also in 1 other manual or revision.
NO FLOW No water flow detected
Display shows: Display shows NO FLOW
What it means
No water flow detected.
Common causes
- Pump is not running
- Low pump pressure
- Pressure switch fault
What to check, in order
- Check breakers, power source and wiring; set the time clock and current time
- Clean the filter or clear blockage; check valve positions
- Adjust or replace the pressure switch; refer to qualified service personnel
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: LXi 250, LXi 400
Source: the Jandy installation & operation manual (H0286900 Rev N), page 42. maker's manual (PDF) The same code is also in 1 other manual or revision.
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Jandy code FAULT- PUMP mean on LXi heaters?
Pump is not running while the control is in Maintain Temp mode (normal). First check: No service required; normal in Maintain Temp mode.
What does Jandy code FAULT- HIGH LIMIT mean on LXi heaters?
Water temperature in the heater exceeds the internal limit, or limit switch fault. First check: Check the high limit switches, run a temperature rise test, and find and fix what is causing the overheating. Refer to qualified service personnel.
What does Jandy code FAULT- FUSELINK/FIELD mean on LXi heaters?
Roll-out (fusible link) fault or vent temperature limit fault. First check: Replace the roll-out (fusible link) switch, or tighten any loose connections. Refer to qualified service personnel.
What does Jandy code FAULT- CHECK IGN CONTROL mean on LXi heaters?
Ignition control fault (see the ignition control LED codes). First check: Check tubing and replace if needed.
What does Jandy code FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSOR mean on LXi heaters?
Water temperature sensor shorted or open. First check: Check sensor wiring and its connection to the Power Interface Board.
Related
- Jandy JXiQ heaters
- Jandy JXi heaters
- Jandy CXi commercial heaters
- Jandy Legacy LRZ heaters
- Jandy Lite2 LJ heaters
- All Jandy error codes
- All pool equipment error codes
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.