Get Started

Pool heaters

Jandy JXi heater error codes

11 codes for JXi200, JXi260, JXi400: what each one means, what to check first, and when to call a pro.

Safety first

Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.

Jump to a code

CodeWhat it means
FAULT - HIGH FLUE TEMPERATUREFlue temperature limit fault
FAULT- CHECK IGN CONTROLIgnition control fault (see the ignition control LED codes)
FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSORWater temperature sensor shorted or open
FAULT- PUMPStatus message: the filter pump is currently off while the heater is programmed in Maintain Temp mode
LED on continuouslyIgnition control fault
LED single flashAir flow fault
LED double flashFlame is present with no call for heat
LED triple flashIgnition lockout: three unsuccessful attempts to fire
AUX MonitorAUX Monitor message (no cause listed)
CHECK FLOWWater flow / pressure switch fault message
FAULT- HIGH LIMITWater temperature in the heater exceeds the internal limit, or limit switch fault

FAULT - HIGH FLUE TEMPERATURE Flue temperature limit fault

What it means

Flue temperature limit fault.

Common causes

What to check, in order

  1. Find and correct loose connections
  2. Replace the flue sensor
  3. Refer to qualified service personnel

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

FAULT- CHECK IGN CONTROL Ignition control fault (see the ignition control LED codes)

What it means

Ignition control fault (see the ignition control LED codes).

Common causes

What to check, in order

  1. Check tubing and replace if needed
  2. Correct the fault or replace the fan
  3. Replace the igniter
  4. Verify proper wiring for 120VAC or 240VAC
  5. Check clearances and room ventilation if enclosed; check for blockage at the flue discharge
  6. Check the ignition control LED codes
  7. Verify gas supply line size, length and elbows meet national codes
  8. Fix any loose wiring, or faults with the igniter, gas valve or ignition control.
  9. Refer to qualified service personnel

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSOR Water temperature sensor shorted or open

Display shows: FAULT- SHORTED H2O SENSOR or FAULT- OPEN WATER SENSOR

What it means

Water temperature sensor shorted or open.

Common causes

What to check, in order

  1. Inspect water temperature sensor wiring
  2. Make sure the sensor is connected correctly to the power interface board (PIB)
  3. Replace the water temperature sensor
  4. Refer to qualified service personnel

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

FAULT- PUMP Status message: the filter pump is currently off while the heater is programmed in Maintain Temp mode

What it means

Status message: the filter pump is currently off while the heater is programmed in Maintain Temp mode.

Common causes

What to check, in order

  1. No service required; normal in Maintain Temp mode

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

LED on continuously Ignition control fault

Display shows: Ignition control LED on continuously

What it means

Ignition control fault.

Common causes

What to check, in order

  1. Refer to qualified service personnel

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

LED single flash Air flow fault

Display shows: Ignition control LED single flash

What it means

Air flow fault.

Common causes

What to check, in order

  1. See the service diagnostic messages for causes and remedies

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

LED double flash Flame is present with no call for heat

Display shows: Ignition control LED double flash

What it means

Flame is present with no call for heat.

Common causes

What to check, in order

  1. Refer to qualified service personnel

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

LED triple flash Ignition lockout: three unsuccessful attempts to fire

Display shows: Ignition control LED triple flash

What it means

Ignition lockout: three unsuccessful attempts to fire; soft lockout.

Common causes

What to check, in order

  1. See the service diagnostic messages for causes and remedies

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

AUX Monitor AUX Monitor message (no cause listed)

What it means

AUX Monitor message (no cause listed).

What to check, in order

  1. Check VersaFlo

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF)

CHECK FLOW Water flow / pressure switch fault message

What it means

Water flow / pressure switch fault message.

Common causes

What to check, in order

  1. Check breakers, power source and wiring; set the time clock and current time
  2. Clean the filter or clear blockage; check valve positions
  3. Confirm return eyeball fittings are fitted on the pool wall.
  4. Adjust or replace the pressure switch
  5. Adjust the variable speed pump
  6. Refer to qualified service personnel

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

FAULT- HIGH LIMIT Water temperature in the heater exceeds the internal limit, or limit switch fault

What it means

Water temperature in the heater exceeds the internal limit, or limit switch fault.

Common causes

What to check, in order

  1. Inspect the vent for obstructions or blockages
  2. Indoor installs: check the vent pipe for bird, insect or rodent blockage
  3. Replace switches
  4. Refer to qualified service personnel

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.

Applies to: JXi200, JXi260, JXi400
Source: the Jandy installation & operation manual (H0574300 Rev H), page 43. maker's manual (PDF) The same code is also in 1 other manual or revision.

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Jandy code FAULT - HIGH FLUE TEMPERATURE mean on JXi heaters?

Flue temperature limit fault. First check: Find and correct loose connections.

What does Jandy code FAULT- CHECK IGN CONTROL mean on JXi heaters?

Ignition control fault (see the ignition control LED codes). First check: Check tubing and replace if needed.

What does Jandy code FAULT- SHORTED H2O SENSOR / FAULT- OPEN WATER SENSOR mean on JXi heaters?

Water temperature sensor shorted or open. First check: Inspect water temperature sensor wiring.

What does Jandy code FAULT- PUMP mean on JXi heaters?

Status message: the filter pump is currently off while the heater is programmed in Maintain Temp mode. First check: No service required; normal in Maintain Temp mode.

What does Jandy code LED on continuously mean on JXi heaters?

Ignition control fault. First check: Refer to qualified service personnel.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.