Raypak Avia heater (264 & 404) error codes

80 codes for 264, 404, 264B, 404B, 264A, 404A: what each one means, what to check first, and when to call a pro.

Safety first

Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.

Jump to a code

CodeWhat it means
No Demand264, 404 …Status: water temperature is equal to or above setpoint (heater in standby)
No Demand264A, 404AStatus: Pool/Spa SET temperature is satisfied
Verifying WaterStatus: 2-minute wait for water pressure/flow
Pre-Purge264, 404 …Status: call for heat established (blower pre-purge 45 s)
Pre-Purge264A, 404AStatus: blower pre-purge for 45 seconds, then spark and ignite
Spark264, 404 …Status: spark operating
Spark264A, 404AStatus: spark and ignite after the 45-second pre-purge
Heating264, 404 …Status: flame present, heating
Heating264A, 404AStatus: heater setpoint, water temperature and 'Heating' shown
Post-Purge264, 404 …Status: heating terminated, cool down (blower post-purge 3 min)
Post-Purge264A, 404AStatus: blower post-purge for 3 minutes
No Communication With IgnitionUser interface cannot communicate with the ignition board
In Sensor Fault264, 404 …The water inlet thermistors disagree by over 3°F (1.5°C)
In Sensor Fault264A, 404AInlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart
In Sensor Open264, 404 …Water inlet thermistor failed open (below 6°F / -14°C)
In Sensor Open264A, 404AInlet sensor open (cut wire / bad connection)
In Sensor Short264, 404 …Water inlet thermistor has failed shorted (over 188°F / 86.5°C)
In Sensor Short264A, 404AInlet sensor short (bare wire touching cabinet)
Out Sensor OpenWater outlet thermistor failed open (below 6°F / -14°C)
Out Sensor ShortWater outlet thermistor has failed shorted (over 188°F / 86.5°C)
Flue Sensor Open264, 404 …Flue temperature sensor has failed open (over 464°F / 240°C)
Flue Sensor Open264A, 404AVent (flue) temperature sensor open
Flue Sensor ShrtFlue temperature sensor has failed shorted (under 7.5°F / -13.5°C)
Flow Sensor FailWhen equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min))
Flame w/o CFH264, 404 …Board senses flame while the gas valve is commanded shut
Flame w/o CFH264A, 404AFlame without call for heat (flow chart fault message)
Gas Valve FaultGas valve sensed ON when commanded OFF
Pump Ctl FailIf fitted: the Protégé pump control is enabled but does not answer commands
WChem Brd FailWhen available: disable the WChem setting in the Program menu to clear this fault
Diff Sw Closed264, 404 …Differential pressure switch closed when the fan is not commanded
Diff Sw Closed264A, 404ADifferential pressure switch closed (flow chart fault message)
Diff Sw Open264, 404 …Fan commanded for 10 seconds without the differential switch closing
Diff Sw Open264A, 404ADifferential pressure switch open (flow chart fault message)
Internal Fault or EEPROM FaultMemory fault
Clock/Fireman Sw264, 404 …Time clock / fireman switch circuit is open
Clock/Fireman Sw264A, 404AFireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the…
Low Temp Lockout264, 404 …Water temperature below 36°F (2°C)
Low Temp Lockout264A, 404AInlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes…
Low Voltage264, 404 …Controller supply voltage below 23 VAC
Low Voltage264A, 404AThe controller is getting less than 23 VAC
Sensor MisplacedInlet/outlet sensor installation or piping problem
Flame Lost264, 404 …Flame was not detected (while heating)
Flame Lost264A, 404AFlame lost (flow chart fault message)
Flame Flickering264, 404 …Listed in the flow-chart troubleshooting box with Flame Lost
Flame Flickering264A, 404AFlame flickering (flow chart fault message)
Water Sw OpenWater pressure switch open
Vent Sw OpenVent (air) switch is open
Hi Limit 1 Fault264, 404 …High-temp limit 1 is open and resets itself
Hi Limit 1 Fault264A, 404AHigh limit switch 1 fault (temperature limit switch open)
Hi Limit 2 Fault264, 404 …High-temp limit 2 is open and resets itself
Hi Limit 2 Fault264A, 404AHigh limit switch 2 fault (temperature limit switch open)
Cabinet Temp LmCabinet temperature limit open
Air SW OpenAir pressure switch open
Fan Lockout264, 404 …3 air switch faults occurred in one heat demand cycle
Fan Lockout264A, 404AFan lockout (flow chart fault message
Diff Sw FaultDifferential pressure switch fault
Ign Try Failure264, 404 …Unit failed to ignite on the first or second try
Ign Try Failure264A, 404AIgnition try failure (flow chart fault message)
Ign 60 min Delay264, 404 …Gas valve failed 3 times in one call for heat
Ign 60 min Delay264A, 404AIgnition 60-minute delay (flow chart fault message)
Ignition Lockout264, 404 …When available: single-try ignition failed and locked out
Ignition Lockout264A, 404AIgnition lockout (flow chart fault message)
Flue Over Temp264, 404 …Flue temperature went over 390°F (199°C)
Flue Over Temp264A, 404AFlue temperature higher than 390°F (199°C)
Remote Wire Err264, 404 …Remote mode active with both Spa and Pool inputs energized
Remote Wire Err264A, 404ARemote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together
Outlet Over TempOutlet temperature went over 180°F (82.0°C)
Low Flow Fault264, 404 …Low flow detected in the heater (possible scaling)
Low Flow Fault264A, 404ALow flow fault (flow chart fault message)
High Flow Fault264, 404 …High flow detected in the heater (possible condensation)
High Flow Fault264A, 404AHigh flow fault (flow chart fault message)
Flue Low Temp264, 404 …Warning: flue temperature below 175°F (79.5°C), possible condensation
Flue Low Temp264A, 404AVent (flue) temperature sensor reports low temperature
Flue Extreme LowFlue temperature is under 140°F (60°C)
Call Service264, 404 …Faults keep coming back
Call Service264A, 404AFlue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout
Exit Remote Mode to Adjust TempRemote operation is active
Internal FaultFaulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable
EEPROM FaultMemory failure
Gas ValveGas valve fault (flow chart fault message)

No Demand Status: water temperature is equal to or above setpoint (heater in standby)

On: 264, 404 …

What it means

Status: water temperature is equal to or above setpoint (heater in standby).

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

No Demand Status: Pool/Spa SET temperature is satisfied

On: 264A, 404A

What it means

Status: Pool/Spa SET temperature is satisfied.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 18. maker's manual (PDF)

Verifying Water Status: 2-minute wait for water pressure/flow

What it means

Status: 2-minute wait for water pressure/flow.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 3 other manuals or revisions.

Pre-Purge Status: call for heat established (blower pre-purge 45 s)

On: 264, 404 …

What it means

Status: call for heat established (blower pre-purge 45 s).

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Pre-Purge Status: blower pre-purge for 45 seconds, then spark and ignite

On: 264A, 404A

What it means

Status: blower pre-purge for 45 seconds, then spark and ignite.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)

Spark Status: spark operating

On: 264, 404 …

What it means

Status: spark operating.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Spark Status: spark and ignite after the 45-second pre-purge

On: 264A, 404A

What it means

Status: spark and ignite after the 45-second pre-purge.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)

Heating Status: flame present, heating

On: 264, 404 …

What it means

Status: flame present, heating.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Ask Blue freeGive your techs Blue

Heating Status: heater setpoint, water temperature and 'Heating' shown

On: 264A, 404A

What it means

Status: heater setpoint, water temperature and 'Heating' shown; unit heats until demand is satisfied.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)

Post-Purge Status: heating terminated, cool down (blower post-purge 3 min)

On: 264, 404 …

What it means

Status: heating terminated, cool down (blower post-purge 3 min).

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Post-Purge Status: blower post-purge for 3 minutes

On: 264A, 404A

What it means

Status: blower post-purge for 3 minutes.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 18. maker's manual (PDF)

No Communication With Ignition User interface cannot communicate with the ignition board

What it means

User interface cannot communicate with the ignition board.

Common causes

What to check, in order

  1. Check P7 and harness wires

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control or control boards is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.

In Sensor Fault The water inlet thermistors disagree by over 3°F (1.5°C)

On: 264, 404 …

What it means

The water inlet thermistors disagree by over 3°F (1.5°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

In Sensor Fault Inlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart

On: 264A, 404A

What it means

Inlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
  3. Replace the ignition board if sensor readings are right

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)

In Sensor Open Water inlet thermistor failed open (below 6°F / -14°C)

On: 264, 404 …

What it means

Water inlet thermistor failed open (below 6°F / -14°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

In Sensor Open Inlet sensor open (cut wire / bad connection)

On: 264A, 404A

What it means

Inlet sensor open (cut wire / bad connection).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
  3. Replace the ignition board if sensor readings are right

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)

In Sensor Short Water inlet thermistor has failed shorted (over 188°F / 86.5°C)

On: 264, 404 …

What it means

Water inlet thermistor has failed shorted (over 188°F / 86.5°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

In Sensor Short Inlet sensor short (bare wire touching cabinet)

On: 264A, 404A

What it means

Inlet sensor short (bare wire touching cabinet).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
  3. Replace the ignition board if sensor readings are right

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)

Out Sensor Open Water outlet thermistor failed open (below 6°F / -14°C)

What it means

Water outlet thermistor failed open (below 6°F / -14°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Out Sensor Short Water outlet thermistor has failed shorted (over 188°F / 86.5°C)

What it means

Water outlet thermistor has failed shorted (over 188°F / 86.5°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flue Sensor Open Flue temperature sensor has failed open (over 464°F / 240°C)

On: 264, 404 …

What it means

Flue temperature sensor has failed open (over 464°F / 240°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flue Sensor Open Vent (flue) temperature sensor open

On: 264A, 404A

What it means

Vent (flue) temperature sensor open.

Common causes

What to check, in order

  1. Check wiring integrity
  2. Look for damaged or loose wires and terminals.
  3. Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
  4. Replace the ignition board if sensor readings are right

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)

Flue Sensor Shrt Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C)

What it means

Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
  3. If sensor readings are right, replace the ignition board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Flow Sensor Fail When equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min))

What it means

When equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min)).

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flame w/o CFH Board senses flame while the gas valve is commanded shut

On: 264, 404 …

What it means

Board senses flame while the gas valve is commanded shut.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check voltage at the valve terminals: energized = replace the control boards, not energized = replace the valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flame w/o CFH Flame without call for heat (flow chart fault message)

On: 264A, 404A

What it means

Flame without call for heat (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check voltage at the valve terminals: if energized, replace the control boards; check the gas valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 26. maker's manual (PDF)

Gas Valve Fault Gas valve sensed ON when commanded OFF

What it means

Gas valve sensed ON when commanded OFF; 60-minute soft lockout.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check voltage at the valve terminals: energized = replace the control boards, not energized = replace the valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Pump Ctl Fail If fitted: the Protégé pump control is enabled but does not answer commands

What it means

If fitted: the Protégé pump control is enabled but does not answer commands.

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

WChem Brd Fail When available: disable the WChem setting in the Program menu to clear this fault

What it means

When available: disable the WChem setting in the Program menu to clear this fault.

Common causes

What to check, in order

  1. Disable the WChem setting in the Program menu

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.

Diff Sw Closed Differential pressure switch closed when the fan is not commanded

On: 264, 404 …

What it means

Differential pressure switch closed when the fan is not commanded.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check blower and air pressure switch: replace the pressure switch if it fails open or closed; replace the blower if operation is intermittent

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Diff Sw Closed Differential pressure switch closed (flow chart fault message)

On: 264A, 404A

What it means

Differential pressure switch closed (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Diff Sw Open Fan commanded for 10 seconds without the differential switch closing

On: 264, 404 …

What it means

Fan commanded for 10 seconds without the differential switch closing.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check blower and air pressure switch: replace the pressure switch if it fails open or closed; replace the blower if operation is intermittent

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Diff Sw Open Differential pressure switch open (flow chart fault message)

On: 264A, 404A

What it means

Differential pressure switch open (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Internal Fault or EEPROM Fault Memory fault

What it means

Memory fault.

Common causes

What to check, in order

  1. Reset setpoints
  2. Replace the board if the fault does not clear

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Clock/Fireman Sw Time clock / fireman switch circuit is open

On: 264, 404 …

What it means

Time clock / fireman switch circuit is open.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Switch connected to the safety loop is in OFF mode

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Clock/Fireman Sw Fireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the…

On: 264A, 404A

What it means

Fireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the heater goes off roughly 15 minutes ahead of the pump).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)

Low Temp Lockout Water temperature below 36°F (2°C)

On: 264, 404 …

What it means

Water temperature below 36°F (2°C).

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Low Temp Lockout Inlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes…

On: 264A, 404A

What it means

Inlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes harmful condensation).

Common causes

What to check, in order

  1. For cold weather, you could hold the heater at 50°F to 70°F (10°C - 21°C) as a preset, or at the lowest setting that avoids condensation, and then bring it up to swimming temperature.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 25. maker's manual (PDF)

Low Voltage Controller supply voltage below 23 VAC

On: 264, 404 …

What it means

Controller supply voltage below 23 VAC.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. If voltage is under 23VAC, check the main voltage.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Low Voltage The controller is getting less than 23 VAC

On: 264A, 404A

What it means

The controller is getting less than 23 VAC. Fix: raise the voltage.

Common causes

What to check, in order

  1. Check voltage in power line
  2. Check transformer voltage
  3. Check ignition board
  4. Flow chart: replace transformer if voltage is below 23VAC

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)

Sensor Misplaced Inlet/outlet sensor installation or piping problem

What it means

Inlet/outlet sensor installation or piping problem.

Common causes

What to check, in order

  1. Check inlet and outlet sensor installation
  2. Check piping and pump operation

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.

Flame Lost Flame was not detected (while heating)

On: 264, 404 …

What it means

Flame was not detected (while heating).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify gas supply and gas valve operation
  3. Cut power, check and clean the igniter rods

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flame Lost Flame lost (flow chart fault message)

On: 264A, 404A

What it means

Flame lost (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify gas supply
  3. Verify gas valve operation
  4. Cut power, verify and clean igniter rods

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Flame Flickering Listed in the flow-chart troubleshooting box with Flame Lost

On: 264, 404 …

What it means

Listed in the flow-chart troubleshooting box with Flame Lost.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify gas supply and gas valve operation
  3. Cut power, check and clean the igniter rods

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 50. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flame Flickering Flame flickering (flow chart fault message)

On: 264A, 404A

What it means

Flame flickering (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify gas supply
  3. Verify gas valve operation
  4. Cut power, verify and clean igniter rods

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Water Sw Open Water pressure switch open

What it means

Water pressure switch open.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow / pressure
  3. Clean the filter/strainer

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Vent Sw Open Vent (air) switch is open

What it means

Vent (air) switch is open. Look for blockages in the vent.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Vent switch open: troubleshoot the extractor if installed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or venting / flue is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Hi Limit 1 Fault High-temp limit 1 is open and resets itself

On: 264, 404 …

What it means

High-temp limit 1 is open and resets itself. With board firmware 1.10 and 2.10, pressing MODE clears the lockout. Check water flow.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Inspect the internal thermostat (Unitherm Governor) and bypass valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Hi Limit 1 Fault High limit switch 1 fault (temperature limit switch open)

On: 264A, 404A

What it means

High limit switch 1 fault (temperature limit switch open).

Common causes

What to check, in order

  1. Verify adequate water flow
  2. Adjust (partially close) the external bypass
  3. Check the Unitherm Governor and internal bypass
  4. Inspect for scale, restricted flow
  5. Look for damaged or loose wires and terminals.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF)

Hi Limit 2 Fault High-temp limit 2 is open and resets itself

On: 264, 404 …

What it means

High-temp limit 2 is open and resets itself. With board firmware 1.10 and 2.10, pressing MODE clears the lockout. Check water flow.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Inspect the internal thermostat (Unitherm Governor) and bypass valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Hi Limit 2 Fault High limit switch 2 fault (temperature limit switch open)

On: 264A, 404A

What it means

High limit switch 2 fault (temperature limit switch open).

Common causes

What to check, in order

  1. Verify adequate water flow
  2. Adjust (partially close) the external bypass
  3. Check the Unitherm Governor and internal bypass
  4. Inspect for scale, restricted flow
  5. Look for damaged or loose wires and terminals.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF)

Cabinet Temp Lm Cabinet temperature limit open

What it means

Cabinet temperature limit open.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Inspect the internal thermostat (Unitherm Governor) and bypass valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Air SW Open Air pressure switch open

What it means

Air pressure switch open.

Common causes

What to check, in order

  1. Check for air inlet obstruction
  2. Look for damaged or loose wires and terminals.
  3. Air pressure switch failed while running: confirm the blower is working.
  4. Check for air inlet/outlet obstructions
  5. Verify air pressure

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Fan Lockout 3 air switch faults occurred in one heat demand cycle

On: 264, 404 …

What it means

3 air switch faults occurred in one heat demand cycle; turn power off and on to clear.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify blower operation
  3. Check for air inlet/outlet obstructions
  4. Verify air pressure
  5. Cycle power to clear

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Fan Lockout Fan lockout (flow chart fault message

On: 264A, 404A

What it means

Fan lockout (flow chart fault message; listed in both blower groups). One of the errors that trigger 'Call Service' when repeated.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent
  3. Air pressure switch failed while running: confirm the blower is working.
  4. Check for air inlet/outlet obstructions
  5. Verify air pressure

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Diff Sw Fault Differential pressure switch fault

What it means

Differential pressure switch fault.

Common causes

What to check, in order

  1. Check fan operation and fan power supply
  2. Look for damaged or loose wires and terminals.
  3. Air pressure switch failed while running: confirm the blower is working.
  4. Check for air inlet/outlet obstructions
  5. Verify air pressure

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Ign Try Failure Unit failed to ignite on the first or second try

On: 264, 404 …

What it means

Unit failed to ignite on the first or second try. Check gas supply.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check gas supply and valve operation
  3. Check the spark igniter and wire; replace if damaged

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Ign Try Failure Ignition try failure (flow chart fault message)

On: 264A, 404A

What it means

Ignition try failure (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
  3. Check igniter and wire; replace if damaged

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Ign 60 min Delay Gas valve failed 3 times in one call for heat

On: 264, 404 …

What it means

Gas valve failed 3 times in one call for heat; locked out 60 minutes.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check gas supply and valve operation
  3. Check the spark igniter and wire; replace if damaged

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Ign 60 min Delay Ignition 60-minute delay (flow chart fault message)

On: 264A, 404A

What it means

Ignition 60-minute delay (flow chart fault message). One of the errors that trigger 'Call Service' when repeated.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
  3. Check igniter and wire; replace if damaged

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Ignition Lockout When available: single-try ignition failed and locked out

On: 264, 404 …

What it means

When available: single-try ignition failed and locked out; power must be cycled to clear.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check gas supply and valve operation
  3. Check the spark igniter and wire; replace if damaged
  4. Cycle power to clear

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Ignition Lockout Ignition lockout (flow chart fault message)

On: 264A, 404A

What it means

Ignition lockout (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
  3. Check igniter and wire; replace if damaged

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Flue Over Temp Flue temperature went over 390°F (199°C)

On: 264, 404 …

What it means

Flue temperature went over 390°F (199°C); cycle power to clear.

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check for obstructions
  3. Troubleshoot the extractor if installed
  4. Cycle power to clear

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or venting / flue is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flue Over Temp Flue temperature higher than 390°F (199°C)

On: 264A, 404A

What it means

Flue temperature higher than 390°F (199°C); will shut down the unit. Service attention is required.

Common causes

What to check, in order

  1. Service attention is required
  2. Look for damaged or loose wires and terminals.
  3. Verify obstructions
  4. Troubleshoot the extractor if installed

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 25. maker's manual (PDF)

Remote Wire Err Remote mode active with both Spa and Pool inputs energized

On: 264, 404 …

What it means

Remote mode active with both Spa and Pool inputs energized.

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Remote Wire Err Remote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together

On: 264A, 404A

What it means

Remote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together.

Common causes

What to check, in order

  1. Wire the remote as in the 'Correct ways to connect remote wiring' diagrams (Pool, Spa)

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 22. maker's manual (PDF)

Outlet Over Temp Outlet temperature went over 180°F (82.0°C)

What it means

Outlet temperature went over 180°F (82.0°C).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Verify gas supply and combustion

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or gas supply and pressure is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Low Flow Fault Low flow detected in the heater (possible scaling)

On: 264, 404 …

What it means

Low flow detected in the heater (possible scaling).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow and pump operation
  3. Adjust flow as needed
  4. Check filter pressure and clean if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Low Flow Fault Low flow fault (flow chart fault message)

On: 264A, 404A

What it means

Low flow fault (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Verify pump operation
  4. Adjust flow as necessary
  5. Verify filter pressure and clean if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

High Flow Fault High flow detected in the heater (possible condensation)

On: 264, 404 …

What it means

High flow detected in the heater (possible condensation).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow and pump operation
  3. Adjust flow as needed
  4. Check filter pressure and clean if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

High Flow Fault High flow fault (flow chart fault message)

On: 264A, 404A

What it means

High flow fault (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Verify water flow
  3. Verify pump operation
  4. Adjust flow as necessary
  5. Verify filter pressure and clean if needed

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)

Flue Low Temp Warning: flue temperature below 175°F (79.5°C), possible condensation

On: 264, 404 …

What it means

Warning: flue temperature below 175°F (79.5°C), possible condensation.

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Flue Low Temp Vent (flue) temperature sensor reports low temperature

On: 264A, 404A

What it means

Vent (flue) temperature sensor reports low temperature.

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)

Flue Extreme Low Flue temperature is under 140°F (60°C)

What it means

Flue temperature is under 140°F (60°C); service is needed. Press MODE to clear the lockout.

Common causes

What to check, in order

  1. Press MODE to remove lockout
  2. Service required

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.

Call Service Faults keep coming back

On: 264, 404 …

What it means

Faults keep coming back; look over the heater, gas, vent and water systems. It resets itself once a 60 min lockout ends; on firmware 1.10/2.10, hold SERVICE 15-20 s.

Common causes

What to check, in order

  1. Contact service support

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.

Call Service Flue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout

On: 264A, 404A

What it means

Flue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout.

Common causes

What to check, in order

  1. Press and hold SERVICE for 20 seconds
  2. Press and hold MODE for 5 seconds
  3. Lockout is cleared; then troubleshoot the cause

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 35. maker's manual (PDF)

Exit Remote Mode to Adjust Temp Remote operation is active

What it means

Remote operation is active; UP, DOWN and MODE keys on the touchpad are disabled.

Common causes

What to check, in order

  1. Press UP and DOWN for 3 seconds to disable Remote mode, then adjust the Pool/Spa set temperature

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 22. maker's manual (PDF)

Internal Fault Faulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable

What it means

Faulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable. Recovery: internal error cleared.

Common causes

What to check, in order

  1. Check for board defects
  2. Replace board

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)

EEPROM Fault Memory failure

What it means

Memory failure. Recovery: EEPROM fault cleared.

Common causes

What to check, in order

  1. Check for board defects
  2. Replace board

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)

Gas Valve Gas valve fault (flow chart fault message)

What it means

Gas valve fault (flow chart fault message).

Common causes

What to check, in order

  1. Look for damaged or loose wires and terminals.
  2. Check voltage at the valve terminals: if energized, replace the control boards; check the gas valve

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.

Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 26. maker's manual (PDF)

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Raypak code Flue Sensor Shrt mean on Avia heaters (264 & 404)?

Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C). First check: Look for damaged or loose wires and terminals.

What does Raypak code Water Sw Open mean on Avia heaters (264 & 404)?

Water pressure switch open. First check: Look for damaged or loose wires and terminals.

What does Raypak code Vent Sw Open mean on Avia heaters (264 & 404)?

Vent (air) switch is open. Look for blockages in the vent. First check: Look for damaged or loose wires and terminals.

What does Raypak code Cabinet Temp Lm mean on Avia heaters (264 & 404)?

Cabinet temperature limit open. First check: Look for damaged or loose wires and terminals.

What does Raypak code Air SW Open mean on Avia heaters (264 & 404)?

Air pressure switch open. First check: Check for air inlet obstruction.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.