Safety first
Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.
Jump to a code
| Code | What it means |
|---|---|
| No Demand264, 404 … | Status: water temperature is equal to or above setpoint (heater in standby) |
| No Demand264A, 404A | Status: Pool/Spa SET temperature is satisfied |
| Verifying Water | Status: 2-minute wait for water pressure/flow |
| Pre-Purge264, 404 … | Status: call for heat established (blower pre-purge 45 s) |
| Pre-Purge264A, 404A | Status: blower pre-purge for 45 seconds, then spark and ignite |
| Spark264, 404 … | Status: spark operating |
| Spark264A, 404A | Status: spark and ignite after the 45-second pre-purge |
| Heating264, 404 … | Status: flame present, heating |
| Heating264A, 404A | Status: heater setpoint, water temperature and 'Heating' shown |
| Post-Purge264, 404 … | Status: heating terminated, cool down (blower post-purge 3 min) |
| Post-Purge264A, 404A | Status: blower post-purge for 3 minutes |
| No Communication With Ignition | User interface cannot communicate with the ignition board |
| In Sensor Fault264, 404 … | The water inlet thermistors disagree by over 3°F (1.5°C) |
| In Sensor Fault264A, 404A | Inlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart |
| In Sensor Open264, 404 … | Water inlet thermistor failed open (below 6°F / -14°C) |
| In Sensor Open264A, 404A | Inlet sensor open (cut wire / bad connection) |
| In Sensor Short264, 404 … | Water inlet thermistor has failed shorted (over 188°F / 86.5°C) |
| In Sensor Short264A, 404A | Inlet sensor short (bare wire touching cabinet) |
| Out Sensor Open | Water outlet thermistor failed open (below 6°F / -14°C) |
| Out Sensor Short | Water outlet thermistor has failed shorted (over 188°F / 86.5°C) |
| Flue Sensor Open264, 404 … | Flue temperature sensor has failed open (over 464°F / 240°C) |
| Flue Sensor Open264A, 404A | Vent (flue) temperature sensor open |
| Flue Sensor Shrt | Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C) |
| Flow Sensor Fail | When equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min)) |
| Flame w/o CFH264, 404 … | Board senses flame while the gas valve is commanded shut |
| Flame w/o CFH264A, 404A | Flame without call for heat (flow chart fault message) |
| Gas Valve Fault | Gas valve sensed ON when commanded OFF |
| Pump Ctl Fail | If fitted: the Protégé pump control is enabled but does not answer commands |
| WChem Brd Fail | When available: disable the WChem setting in the Program menu to clear this fault |
| Diff Sw Closed264, 404 … | Differential pressure switch closed when the fan is not commanded |
| Diff Sw Closed264A, 404A | Differential pressure switch closed (flow chart fault message) |
| Diff Sw Open264, 404 … | Fan commanded for 10 seconds without the differential switch closing |
| Diff Sw Open264A, 404A | Differential pressure switch open (flow chart fault message) |
| Internal Fault or EEPROM Fault | Memory fault |
| Clock/Fireman Sw264, 404 … | Time clock / fireman switch circuit is open |
| Clock/Fireman Sw264A, 404A | Fireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the… |
| Low Temp Lockout264, 404 … | Water temperature below 36°F (2°C) |
| Low Temp Lockout264A, 404A | Inlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes… |
| Low Voltage264, 404 … | Controller supply voltage below 23 VAC |
| Low Voltage264A, 404A | The controller is getting less than 23 VAC |
| Sensor Misplaced | Inlet/outlet sensor installation or piping problem |
| Flame Lost264, 404 … | Flame was not detected (while heating) |
| Flame Lost264A, 404A | Flame lost (flow chart fault message) |
| Flame Flickering264, 404 … | Listed in the flow-chart troubleshooting box with Flame Lost |
| Flame Flickering264A, 404A | Flame flickering (flow chart fault message) |
| Water Sw Open | Water pressure switch open |
| Vent Sw Open | Vent (air) switch is open |
| Hi Limit 1 Fault264, 404 … | High-temp limit 1 is open and resets itself |
| Hi Limit 1 Fault264A, 404A | High limit switch 1 fault (temperature limit switch open) |
| Hi Limit 2 Fault264, 404 … | High-temp limit 2 is open and resets itself |
| Hi Limit 2 Fault264A, 404A | High limit switch 2 fault (temperature limit switch open) |
| Cabinet Temp Lm | Cabinet temperature limit open |
| Air SW Open | Air pressure switch open |
| Fan Lockout264, 404 … | 3 air switch faults occurred in one heat demand cycle |
| Fan Lockout264A, 404A | Fan lockout (flow chart fault message |
| Diff Sw Fault | Differential pressure switch fault |
| Ign Try Failure264, 404 … | Unit failed to ignite on the first or second try |
| Ign Try Failure264A, 404A | Ignition try failure (flow chart fault message) |
| Ign 60 min Delay264, 404 … | Gas valve failed 3 times in one call for heat |
| Ign 60 min Delay264A, 404A | Ignition 60-minute delay (flow chart fault message) |
| Ignition Lockout264, 404 … | When available: single-try ignition failed and locked out |
| Ignition Lockout264A, 404A | Ignition lockout (flow chart fault message) |
| Flue Over Temp264, 404 … | Flue temperature went over 390°F (199°C) |
| Flue Over Temp264A, 404A | Flue temperature higher than 390°F (199°C) |
| Remote Wire Err264, 404 … | Remote mode active with both Spa and Pool inputs energized |
| Remote Wire Err264A, 404A | Remote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together |
| Outlet Over Temp | Outlet temperature went over 180°F (82.0°C) |
| Low Flow Fault264, 404 … | Low flow detected in the heater (possible scaling) |
| Low Flow Fault264A, 404A | Low flow fault (flow chart fault message) |
| High Flow Fault264, 404 … | High flow detected in the heater (possible condensation) |
| High Flow Fault264A, 404A | High flow fault (flow chart fault message) |
| Flue Low Temp264, 404 … | Warning: flue temperature below 175°F (79.5°C), possible condensation |
| Flue Low Temp264A, 404A | Vent (flue) temperature sensor reports low temperature |
| Flue Extreme Low | Flue temperature is under 140°F (60°C) |
| Call Service264, 404 … | Faults keep coming back |
| Call Service264A, 404A | Flue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout |
| Exit Remote Mode to Adjust Temp | Remote operation is active |
| Internal Fault | Faulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable |
| EEPROM Fault | Memory failure |
| Gas Valve | Gas valve fault (flow chart fault message) |
No Demand Status: water temperature is equal to or above setpoint (heater in standby)
On: 264, 404 …
What it means
Status: water temperature is equal to or above setpoint (heater in standby).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
No Demand Status: Pool/Spa SET temperature is satisfied
On: 264A, 404A
What it means
Status: Pool/Spa SET temperature is satisfied.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 18. maker's manual (PDF)
Verifying Water Status: 2-minute wait for water pressure/flow
What it means
Status: 2-minute wait for water pressure/flow.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Pre-Purge Status: call for heat established (blower pre-purge 45 s)
On: 264, 404 …
What it means
Status: call for heat established (blower pre-purge 45 s).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Pre-Purge Status: blower pre-purge for 45 seconds, then spark and ignite
On: 264A, 404A
What it means
Status: blower pre-purge for 45 seconds, then spark and ignite.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)
Spark Status: spark operating
On: 264, 404 …
What it means
Status: spark operating.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Spark Status: spark and ignite after the 45-second pre-purge
On: 264A, 404A
What it means
Status: spark and ignite after the 45-second pre-purge.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)
Heating Status: flame present, heating
On: 264, 404 …
What it means
Status: flame present, heating.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Heating Status: heater setpoint, water temperature and 'Heating' shown
On: 264A, 404A
What it means
Status: heater setpoint, water temperature and 'Heating' shown; unit heats until demand is satisfied.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 17. maker's manual (PDF)
Post-Purge Status: heating terminated, cool down (blower post-purge 3 min)
On: 264, 404 …
What it means
Status: heating terminated, cool down (blower post-purge 3 min).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 34. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Post-Purge Status: blower post-purge for 3 minutes
On: 264A, 404A
What it means
Status: blower post-purge for 3 minutes.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 18. maker's manual (PDF)
No Communication With Ignition User interface cannot communicate with the ignition board
What it means
User interface cannot communicate with the ignition board.
Common causes
- Communication fault between UI and ignition board
What to check, in order
- Check P7 and harness wires
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control or control boards is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
In Sensor Fault The water inlet thermistors disagree by over 3°F (1.5°C)
On: 264, 404 …
What it means
The water inlet thermistors disagree by over 3°F (1.5°C).
Common causes
- Inlet sensor fault
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
In Sensor Fault Inlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart
On: 264A, 404A
What it means
Inlet sensor failure: the two sensors (100K dual thermistor) read more than 3°F (1.5°C) apart.
Common causes
- Dual thermistor readings disagree
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
- Replace the ignition board if sensor readings are right
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)
In Sensor Open Water inlet thermistor failed open (below 6°F / -14°C)
On: 264, 404 …
What it means
Water inlet thermistor failed open (below 6°F / -14°C).
Common causes
- Inlet sensor open
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
In Sensor Open Inlet sensor open (cut wire / bad connection)
On: 264A, 404A
What it means
Inlet sensor open (cut wire / bad connection).
Common causes
- Cut wire
- Bad connection
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
- Replace the ignition board if sensor readings are right
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)
In Sensor Short Water inlet thermistor has failed shorted (over 188°F / 86.5°C)
On: 264, 404 …
What it means
Water inlet thermistor has failed shorted (over 188°F / 86.5°C).
Common causes
- Inlet sensor shorted
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
In Sensor Short Inlet sensor short (bare wire touching cabinet)
On: 264A, 404A
What it means
Inlet sensor short (bare wire touching cabinet).
Common causes
- Bare wire touching cabinet
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
- Replace the ignition board if sensor readings are right
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 24. maker's manual (PDF)
Out Sensor Open Water outlet thermistor failed open (below 6°F / -14°C)
What it means
Water outlet thermistor failed open (below 6°F / -14°C).
Common causes
- Outlet sensor open
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Out Sensor Short Water outlet thermistor has failed shorted (over 188°F / 86.5°C)
What it means
Water outlet thermistor has failed shorted (over 188°F / 86.5°C).
Common causes
- Outlet sensor shorted
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flue Sensor Open Flue temperature sensor has failed open (over 464°F / 240°C)
On: 264, 404 …
What it means
Flue temperature sensor has failed open (over 464°F / 240°C).
Common causes
- Flue sensor open
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flue Sensor Open Vent (flue) temperature sensor open
On: 264A, 404A
What it means
Vent (flue) temperature sensor open.
Common causes
- Vent temperature sensor open
What to check, in order
- Check wiring integrity
- Look for damaged or loose wires and terminals.
- Verify the sensor per the manufacturer's temperature-resistance chart: replace the sensor if readings are out of range
- Replace the ignition board if sensor readings are right
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)
Flue Sensor Shrt Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C)
What it means
Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C).
Common causes
- Flue sensor shorted
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify the sensor against the manufacturer's temperature-resistance chart; replace the sensor if out of range
- If sensor readings are right, replace the ignition board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, wiring or venting / flue is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Flow Sensor Fail When equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min))
What it means
When equipped: flow sensor reading out of range (0 to 100 GPM (378 L/min)).
Common causes
- Flow sensor fault
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flame w/o CFH Board senses flame while the gas valve is commanded shut
On: 264, 404 …
What it means
Board senses flame while the gas valve is commanded shut.
Common causes
- Flame with no call for heat
What to check, in order
- Look for damaged or loose wires and terminals.
- Check voltage at the valve terminals: energized = replace the control boards, not energized = replace the valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flame w/o CFH Flame without call for heat (flow chart fault message)
On: 264A, 404A
What it means
Flame without call for heat (flow chart fault message).
Common causes
- Flame sensed without call for heat
What to check, in order
- Look for damaged or loose wires and terminals.
- Check voltage at the valve terminals: if energized, replace the control boards; check the gas valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 26. maker's manual (PDF)
Gas Valve Fault Gas valve sensed ON when commanded OFF
What it means
Gas valve sensed ON when commanded OFF; 60-minute soft lockout.
Common causes
- Gas valve on when commanded off
What to check, in order
- Look for damaged or loose wires and terminals.
- Check voltage at the valve terminals: energized = replace the control boards, not energized = replace the valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Pump Ctl Fail If fitted: the Protégé pump control is enabled but does not answer commands
What it means
If fitted: the Protégé pump control is enabled but does not answer commands.
Common causes
- Pump control not responding
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
WChem Brd Fail When available: disable the WChem setting in the Program menu to clear this fault
What it means
When available: disable the WChem setting in the Program menu to clear this fault.
Common causes
- WChem setting enabled without a working board
What to check, in order
- Disable the WChem setting in the Program menu
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Diff Sw Closed Differential pressure switch closed when the fan is not commanded
On: 264, 404 …
What it means
Differential pressure switch closed when the fan is not commanded.
Common causes
- Differential pressure switch stuck closed
What to check, in order
- Look for damaged or loose wires and terminals.
- Check blower and air pressure switch: replace the pressure switch if it fails open or closed; replace the blower if operation is intermittent
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Diff Sw Closed Differential pressure switch closed (flow chart fault message)
On: 264A, 404A
What it means
Differential pressure switch closed (flow chart fault message).
Common causes
- Differential pressure switch stuck closed
What to check, in order
- Look for damaged or loose wires and terminals.
- Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Diff Sw Open Fan commanded for 10 seconds without the differential switch closing
On: 264, 404 …
What it means
Fan commanded for 10 seconds without the differential switch closing.
Common causes
- Differential pressure switch not closing
What to check, in order
- Look for damaged or loose wires and terminals.
- Check blower and air pressure switch: replace the pressure switch if it fails open or closed; replace the blower if operation is intermittent
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Diff Sw Open Differential pressure switch open (flow chart fault message)
On: 264A, 404A
What it means
Differential pressure switch open (flow chart fault message).
Common causes
- Differential pressure switch not closing
What to check, in order
- Look for damaged or loose wires and terminals.
- Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Internal Fault or EEPROM Fault Memory fault
What it means
Memory fault.
Common causes
- Board memory fault
What to check, in order
- Reset setpoints
- Replace the board if the fault does not clear
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Clock/Fireman Sw Time clock / fireman switch circuit is open
On: 264, 404 …
What it means
Time clock / fireman switch circuit is open.
Common causes
- Switch connected to the safety loop is OFF
What to check, in order
- Look for damaged or loose wires and terminals.
- Switch connected to the safety loop is in OFF mode
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Clock/Fireman Sw Fireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the…
On: 264A, 404A
What it means
Fireman's switch / enable circuit is open (with a fireman's switch wired to a mechanical time clock, the heater goes off roughly 15 minutes ahead of the pump).
Common causes
- Switch connected to the safety loop is in OFF mode
What to check, in order
- Look for damaged or loose wires and terminals.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)
Low Temp Lockout Water temperature below 36°F (2°C)
On: 264, 404 …
What it means
Water temperature below 36°F (2°C).
Common causes
- Water below 36°F (2.2°C)
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Low Temp Lockout Inlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes…
On: 264A, 404A
What it means
Inlet water is colder than 36°F (2°C), so the heater will not run (running for long below 50°F / 10°C causes harmful condensation).
Common causes
- Inlet water below 36°F (2°C)
What to check, in order
- For cold weather, you could hold the heater at 50°F to 70°F (10°C - 21°C) as a preset, or at the lowest setting that avoids condensation, and then bring it up to swimming temperature.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 25. maker's manual (PDF)
Low Voltage Controller supply voltage below 23 VAC
On: 264, 404 …
What it means
Controller supply voltage below 23 VAC.
Common causes
- Low supply voltage
What to check, in order
- Look for damaged or loose wires and terminals.
- If voltage is under 23VAC, check the main voltage.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Low Voltage The controller is getting less than 23 VAC
On: 264A, 404A
What it means
The controller is getting less than 23 VAC. Fix: raise the voltage.
Common causes
- Supply voltage below 23 VAC
What to check, in order
- Check voltage in power line
- Check transformer voltage
- Check ignition board
- Flow chart: replace transformer if voltage is below 23VAC
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)
Sensor Misplaced Inlet/outlet sensor installation or piping problem
What it means
Inlet/outlet sensor installation or piping problem.
Common causes
- Sensors installed in the wrong place
- Piping or pump problem
What to check, in order
- Check inlet and outlet sensor installation
- Check piping and pump operation
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Flame Lost Flame was not detected (while heating)
On: 264, 404 …
What it means
Flame was not detected (while heating).
Common causes
- Flame lost
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify gas supply and gas valve operation
- Cut power, check and clean the igniter rods
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flame Lost Flame lost (flow chart fault message)
On: 264A, 404A
What it means
Flame lost (flow chart fault message).
Common causes
- Flame lost
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify gas supply
- Verify gas valve operation
- Cut power, verify and clean igniter rods
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Flame Flickering Listed in the flow-chart troubleshooting box with Flame Lost
On: 264, 404 …
What it means
Listed in the flow-chart troubleshooting box with Flame Lost.
Common causes
- Unstable flame
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify gas supply and gas valve operation
- Cut power, check and clean the igniter rods
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 50. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flame Flickering Flame flickering (flow chart fault message)
On: 264A, 404A
What it means
Flame flickering (flow chart fault message).
Common causes
- Unstable flame
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify gas supply
- Verify gas valve operation
- Cut power, verify and clean igniter rods
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Water Sw Open Water pressure switch open
What it means
Water pressure switch open.
Common causes
- Low water flow or pressure
- Dirty filter/strainer
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow / pressure
- Clean the filter/strainer
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Vent Sw Open Vent (air) switch is open
What it means
Vent (air) switch is open. Look for blockages in the vent.
Common causes
- Vent switch open
- Vent obstruction
- Extractor fault (if installed)
What to check, in order
- Look for damaged or loose wires and terminals.
- Vent switch open: troubleshoot the extractor if installed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or venting / flue is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Hi Limit 1 Fault High-temp limit 1 is open and resets itself
On: 264, 404 …
What it means
High-temp limit 1 is open and resets itself. With board firmware 1.10 and 2.10, pressing MODE clears the lockout. Check water flow.
Common causes
- Temperature limit switch open
- Low water flow
- Internal thermostat or bypass valve fault
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Inspect the internal thermostat (Unitherm Governor) and bypass valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Hi Limit 1 Fault High limit switch 1 fault (temperature limit switch open)
On: 264A, 404A
What it means
High limit switch 1 fault (temperature limit switch open).
Common causes
- Low water flow
- External bypass open too far
- Unitherm Governor / internal bypass problem
- Scale, restricted flow
What to check, in order
- Verify adequate water flow
- Adjust (partially close) the external bypass
- Check the Unitherm Governor and internal bypass
- Inspect for scale, restricted flow
- Look for damaged or loose wires and terminals.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF)
Hi Limit 2 Fault High-temp limit 2 is open and resets itself
On: 264, 404 …
What it means
High-temp limit 2 is open and resets itself. With board firmware 1.10 and 2.10, pressing MODE clears the lockout. Check water flow.
Common causes
- Temperature limit switch open
- Low water flow
- Internal thermostat or bypass valve fault
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Inspect the internal thermostat (Unitherm Governor) and bypass valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Hi Limit 2 Fault High limit switch 2 fault (temperature limit switch open)
On: 264A, 404A
What it means
High limit switch 2 fault (temperature limit switch open).
Common causes
- Low water flow
- External bypass open too far
- Unitherm Governor / internal bypass problem
- Scale, restricted flow
What to check, in order
- Verify adequate water flow
- Adjust (partially close) the external bypass
- Check the Unitherm Governor and internal bypass
- Inspect for scale, restricted flow
- Look for damaged or loose wires and terminals.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF)
Cabinet Temp Lm Cabinet temperature limit open
What it means
Cabinet temperature limit open.
Common causes
- Cabinet temperature limit open
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Inspect the internal thermostat (Unitherm Governor) and bypass valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Air SW Open Air pressure switch open
What it means
Air pressure switch open.
Common causes
- Air pressure switch open
- Air inlet obstruction
What to check, in order
- Check for air inlet obstruction
- Look for damaged or loose wires and terminals.
- Air pressure switch failed while running: confirm the blower is working.
- Check for air inlet/outlet obstructions
- Verify air pressure
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Fan Lockout 3 air switch faults occurred in one heat demand cycle
On: 264, 404 …
What it means
3 air switch faults occurred in one heat demand cycle; turn power off and on to clear.
Common causes
- Repeated air switch faults
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify blower operation
- Check for air inlet/outlet obstructions
- Verify air pressure
- Cycle power to clear
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Fan Lockout Fan lockout (flow chart fault message
On: 264A, 404A
What it means
Fan lockout (flow chart fault message; listed in both blower groups). One of the errors that trigger 'Call Service' when repeated.
Common causes
- Air pressure switch or blower problem
What to check, in order
- Look for damaged or loose wires and terminals.
- Check blower and air pressure switch: replace the pressure switch if failing open or closed; replace the blower if operation is intermittent
- Air pressure switch failed while running: confirm the blower is working.
- Check for air inlet/outlet obstructions
- Verify air pressure
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Diff Sw Fault Differential pressure switch fault
What it means
Differential pressure switch fault.
Common causes
- Differential pressure switch fault
What to check, in order
- Check fan operation and fan power supply
- Look for damaged or loose wires and terminals.
- Air pressure switch failed while running: confirm the blower is working.
- Check for air inlet/outlet obstructions
- Verify air pressure
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 29. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Ign Try Failure Unit failed to ignite on the first or second try
On: 264, 404 …
What it means
Unit failed to ignite on the first or second try. Check gas supply.
Common causes
- Ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check gas supply and valve operation
- Check the spark igniter and wire; replace if damaged
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Ign Try Failure Ignition try failure (flow chart fault message)
On: 264A, 404A
What it means
Ignition try failure (flow chart fault message).
Common causes
- Ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
- Check igniter and wire; replace if damaged
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Ign 60 min Delay Gas valve failed 3 times in one call for heat
On: 264, 404 …
What it means
Gas valve failed 3 times in one call for heat; locked out 60 minutes.
Common causes
- Repeated ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check gas supply and valve operation
- Check the spark igniter and wire; replace if damaged
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Ign 60 min Delay Ignition 60-minute delay (flow chart fault message)
On: 264A, 404A
What it means
Ignition 60-minute delay (flow chart fault message). One of the errors that trigger 'Call Service' when repeated.
Common causes
- Repeated ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
- Check igniter and wire; replace if damaged
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Ignition Lockout When available: single-try ignition failed and locked out
On: 264, 404 …
What it means
When available: single-try ignition failed and locked out; power must be cycled to clear.
Common causes
- Ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check gas supply and valve operation
- Check the spark igniter and wire; replace if damaged
- Cycle power to clear
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Ignition Lockout Ignition lockout (flow chart fault message)
On: 264A, 404A
What it means
Ignition lockout (flow chart fault message).
Common causes
- Ignition failure
What to check, in order
- Look for damaged or loose wires and terminals.
- Check the gas valve, the gas supply and the spark igniter: confirm gas is supplied and the valve works.
- Check igniter and wire; replace if damaged
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, the igniter or ignition control, wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Flue Over Temp Flue temperature went over 390°F (199°C)
On: 264, 404 …
What it means
Flue temperature went over 390°F (199°C); cycle power to clear.
Common causes
- Flue obstruction
- Extractor fault (if installed)
What to check, in order
- Look for damaged or loose wires and terminals.
- Check for obstructions
- Troubleshoot the extractor if installed
- Cycle power to clear
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or venting / flue is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flue Over Temp Flue temperature higher than 390°F (199°C)
On: 264A, 404A
What it means
Flue temperature higher than 390°F (199°C); will shut down the unit. Service attention is required.
Common causes
- Flue obstruction
- Extractor fault (if installed)
What to check, in order
- Service attention is required
- Look for damaged or loose wires and terminals.
- Verify obstructions
- Troubleshoot the extractor if installed
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 25. maker's manual (PDF)
Remote Wire Err Remote mode active with both Spa and Pool inputs energized
On: 264, 404 …
What it means
Remote mode active with both Spa and Pool inputs energized.
Common causes
- Remote wiring: both inputs energized
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Remote Wire Err Remote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together
On: 264A, 404A
What it means
Remote is wired wrong: orange/black (Spa) and black/orange (Pool) are powered together.
Common causes
- Remote wiring: Spa and Pool inputs powered together
What to check, in order
- Wire the remote as in the 'Correct ways to connect remote wiring' diagrams (Pool, Spa)
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 22. maker's manual (PDF)
Outlet Over Temp Outlet temperature went over 180°F (82.0°C)
What it means
Outlet temperature went over 180°F (82.0°C).
Common causes
- Low water flow
- Gas supply or combustion problem
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Verify gas supply and combustion
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring or gas supply and pressure is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Low Flow Fault Low flow detected in the heater (possible scaling)
On: 264, 404 …
What it means
Low flow detected in the heater (possible scaling).
Common causes
- Low flow
- Possible scaling
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow and pump operation
- Adjust flow as needed
- Check filter pressure and clean if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Low Flow Fault Low flow fault (flow chart fault message)
On: 264A, 404A
What it means
Low flow fault (flow chart fault message).
Common causes
- Low water flow
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Verify pump operation
- Adjust flow as necessary
- Verify filter pressure and clean if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
High Flow Fault High flow detected in the heater (possible condensation)
On: 264, 404 …
What it means
High flow detected in the heater (possible condensation).
Common causes
- High flow
- Possible condensation
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow and pump operation
- Adjust flow as needed
- Check filter pressure and clean if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
High Flow Fault High flow fault (flow chart fault message)
On: 264A, 404A
What it means
High flow fault (flow chart fault message).
Common causes
- High water flow
What to check, in order
- Look for damaged or loose wires and terminals.
- Verify water flow
- Verify pump operation
- Adjust flow as necessary
- Verify filter pressure and clean if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 27. maker's manual (PDF)
Flue Low Temp Warning: flue temperature below 175°F (79.5°C), possible condensation
On: 264, 404 …
What it means
Warning: flue temperature below 175°F (79.5°C), possible condensation.
Common causes
- Low flue temperature
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Flue Low Temp Vent (flue) temperature sensor reports low temperature
On: 264A, 404A
What it means
Vent (flue) temperature sensor reports low temperature.
Common causes
- Low flue temperature
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 30. maker's manual (PDF)
Flue Extreme Low Flue temperature is under 140°F (60°C)
What it means
Flue temperature is under 140°F (60°C); service is needed. Press MODE to clear the lockout.
Common causes
- Very low flue temperature
What to check, in order
- Press MODE to remove lockout
- Service required
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: 264, 404, 264B, 404B, 264A, 404A
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 5 other manuals or revisions.
Call Service Faults keep coming back
On: 264, 404 …
What it means
Faults keep coming back; look over the heater, gas, vent and water systems. It resets itself once a 60 min lockout ends; on firmware 1.10/2.10, hold SERVICE 15-20 s.
Common causes
- Recurrent faults
What to check, in order
- Contact service support
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: 264, 404, 264B, 404B
Source: the Raypak installation & operation manual (P/N 100-10000111 Rev. 08), page 35. maker's manual (PDF) The same code is also in 4 other manuals or revisions.
Call Service Flue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout
On: 264A, 404A
What it means
Flue Over Temp, Ign 60 min Delay or Fan Lockout happening 3 times within 48 run hours shows as a lockout.
Common causes
- Repeated Fan Lockout, Ign 60 min Delay or Flue Over Temp
What to check, in order
- Press and hold SERVICE for 20 seconds
- Press and hold MODE for 5 seconds
- Lockout is cleared; then troubleshoot the cause
When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 35. maker's manual (PDF)
Exit Remote Mode to Adjust Temp Remote operation is active
What it means
Remote operation is active; UP, DOWN and MODE keys on the touchpad are disabled.
Common causes
- Remote mode active
What to check, in order
- Press UP and DOWN for 3 seconds to disable Remote mode, then adjust the Pool/Spa set temperature
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 22. maker's manual (PDF)
Internal Fault Faulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable
What it means
Faulty RAM, ROM, flame circuit or A/D converter, or a corrupted safety variable. Recovery: internal error cleared.
Common causes
- Control board defect
What to check, in order
- Check for board defects
- Replace board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)
EEPROM Fault Memory failure
What it means
Memory failure. Recovery: EEPROM fault cleared.
Common causes
- Memory failure
What to check, in order
- Check for board defects
- Replace board
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 23. maker's manual (PDF)
Gas Valve Gas valve fault (flow chart fault message)
What it means
Gas valve fault (flow chart fault message).
Common causes
- Gas valve or control board fault
What to check, in order
- Look for damaged or loose wires and terminals.
- Check voltage at the valve terminals: if energized, replace the control boards; check the gas valve
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: 264A, 404A
Source: the Raypak tool box quick reference guide (service) (RP-P-600-5 REV C), page 26. maker's manual (PDF)
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Raypak code Flue Sensor Shrt mean on Avia heaters (264 & 404)?
Flue temperature sensor has failed shorted (under 7.5°F / -13.5°C). First check: Look for damaged or loose wires and terminals.
What does Raypak code Water Sw Open mean on Avia heaters (264 & 404)?
Water pressure switch open. First check: Look for damaged or loose wires and terminals.
What does Raypak code Vent Sw Open mean on Avia heaters (264 & 404)?
Vent (air) switch is open. Look for blockages in the vent. First check: Look for damaged or loose wires and terminals.
What does Raypak code Cabinet Temp Lm mean on Avia heaters (264 & 404)?
Cabinet temperature limit open. First check: Look for damaged or loose wires and terminals.
What does Raypak code Air SW Open mean on Avia heaters (264 & 404)?
Air pressure switch open. First check: Check for air inlet obstruction.
Related
- Raypak Digital pool heaters 206A–407A
- Raypak Low NOx pool heaters 207A–407A
- Raypak Atmospheric heaters 268A & 408A
- Raypak Above-ground heaters 106 & 156
- Raypak X94 Professional SR-410 heater
- Raypak MVB commercial heaters & boilers (504A–2004A)
- Raypak XTherm commercial heaters & boilers
- Raypak VERSA IC boiler control
- Raypak ELS electric pool & spa heaters
- All Raypak error codes
- All pool equipment error codes
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.